GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

FKIE_CVE-2023-46664

Vulnerability from fkie_nvd - Published: 2023-10-26 21:15 - Updated: 2026-06-17 06:31
Summary
Sielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "PolyEco1000",
          "vendor": "Sielco ",
          "versions": [
            {
              "status": "affected",
              "version": "CPU:2.0.6 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:1.9.4 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:1.9.3 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:1.7.0 FPGA:10.16"
            },
            {
              "status": "affected",
              "version": "CPU:2.0.2 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:2.0.0 FPGA:10.19"
            }
          ]
        }
      ],
      "source": "ics-cert@hq.dhs.gov"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sielco:polyeco500_firmware:1.7.0:*:*:*:cpu:*:*:*",
              "matchCriteriaId": "E64F96A4-542A-486E-AC9A-3EC1E68A6D1E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:sielco:polyeco500_firmware:10.16:*:*:*:fpga:*:*:*",
              "matchCriteriaId": "E3A4049B-D0B2-4CB6-8B31-ECD3BF4FF384",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sielco:polyeco500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7E931F0-5608-4F24-821B-3DB29972C077",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sielco:polyeco300_firmware:2.0.0:*:*:*:cpu:*:*:*",
              "matchCriteriaId": "BBA5260D-A7D3-4973-8106-E8C73F50A6CE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:sielco:polyeco300_firmware:2.0.2:*:*:*:cpu:*:*:*",
              "matchCriteriaId": "F7CE9236-A970-49F0-A200-84BC3B77CECB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:sielco:polyeco300_firmware:10.19:*:*:*:fpga:*:*:*",
              "matchCriteriaId": "D45CE1CD-FB47-4FFD-974E-B55B569A5850",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sielco:polyeco300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "05832105-6C9E-4850-A145-F3E241058CCA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sielco:polyeco1000_firmware:1.9.3:*:*:*:cpu:*:*:*",
              "matchCriteriaId": "991B1AD8-671D-4EF9-901B-0834748258F5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:sielco:polyeco1000_firmware:1.9.4:*:*:*:cpu:*:*:*",
              "matchCriteriaId": "FE961B31-1553-4457-8436-8F9662AA10CA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:sielco:polyeco1000_firmware:2.0.6:*:*:*:cpu:*:*:*",
              "matchCriteriaId": "0BF0380D-483C-4B14-BF42-AC1E9C79D2DE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:sielco:polyeco1000_firmware:10.19:*:*:*:fpga:*:*:*",
              "matchCriteriaId": "F0E5773E-8842-4FCB-80BD-266A237042E7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sielco:polyeco1000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "01DB9D87-6F35-4171-AD59-9B90386F431E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\n\n\n\n\n\n\n\n\n\n\n\n\nSielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.\n\n\n\n\n\n\n\n"
    },
    {
      "lang": "es",
      "value": "Sielco PolyEco1000 es afectada por una vulnerabilidad de control de acceso inadecuado cuando la aplicaci\u00f3n proporciona acceso directo a objetos bas\u00e1ndose en la entrada proporcionada por el usuario. Como resultado de esta vulnerabilidad, los atacantes pueden eludir la autorizaci\u00f3n y acceder a recursos detr\u00e1s de p\u00e1ginas protegidas."
    }
  ],
  "id": "CVE-2023-46664",
  "lastModified": "2026-06-17T06:31:19.390",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-46664",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2025-01-16T21:20:36.232976Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2023-10-26T21:15:07.967",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…