fkie_cve-2022-34763
Vulnerability from fkie_nvd
Published
2022-07-13 21:15
Modified
2024-11-21 07:10
Summary
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:opc_ua_module_for_m580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C0FE426-148B-4E23-8434-3E9A3F1943D2",
              "versionEndIncluding": "1.10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:opc_ua_module_for_m580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C43DE37-0241-4A43-B761-0A1F2D2684A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:x80_advanced_rtu_module_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FA21E71-EF69-48C5-845B-44FA1D65DF20",
              "versionStartIncluding": "2.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:x80_advanced_rtu_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDD764FE-9165-41E9-9328-93A519CFDB99",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)"
    },
    {
      "lang": "es",
      "value": "Una CWE-345: Se presenta una vulnerabilidad de Verificaci\u00f3n Insuficiente de la Autenticidad de los Datos que podr\u00eda causar la carga de im\u00e1genes de firmware no autorizadas debido a la verificaci\u00f3n incorrecta de la firma del firmware. Productos afectados: X80 advanced RTU Communication Module (BMENOR2200H) (versiones V2.01 y posteriores), OPC UA Modicon Communication Module (BMENUA0100) (versiones V1.10 y anteriores)"
    }
  ],
  "id": "CVE-2022-34763",
  "lastModified": "2024-11-21T07:10:08.413",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.7,
        "impactScore": 5.2,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-07-13T21:15:08.690",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-345"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…