fkie_cve-2021-33710
Vulnerability from fkie_nvd
Published
2021-07-13 11:15
Modified
2024-11-21 06:09
Severity ?
Summary
A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | teamcenter_active_workspace | * | |
siemens | teamcenter_active_workspace | * | |
siemens | teamcenter_active_workspace | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2BB7B04-DD2F-42A8-89ED-0A014C768061", "versionEndExcluding": "4.3.9", "versionStartIncluding": "4.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*", "matchCriteriaId": "3752E0F7-4A3C-411B-9469-443D8C815629", "versionEndExcluding": "5.0.7", "versionStartIncluding": "5.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*", "matchCriteriaId": "4785E6FA-C094-49FD-BF8E-6E41EFF14467", "versionEndExcluding": "5.1.4", "versionStartIncluding": "5.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions \u003c V4.3.9), Teamcenter Active Workspace V5.0 (All versions \u003c V5.0.7), Teamcenter Active Workspace V5.1 (All versions \u003c V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Teamcenter Active Workspace versiones V4 (Todas las versiones anteriores a V4.3.9), Teamcenter Active Workspace versiones V5.0 (Todas las versiones anteriores a V5.0.7), Teamcenter Active Workspace versiones V5.1 (Todas las versiones anteriores a V5.1.4). Se presenta una vulnerabilidad de tipo cross-site scripting (XSS) reflejado en la interfaz web de los dispositivos afectados que podr\u00eda permitir a un atacante ejecutar c\u00f3digo JavaScript malicioso enga\u00f1ando a usuarios para que accedan a un enlace malicioso" } ], "id": "CVE-2021-33710", "lastModified": "2024-11-21T06:09:25.350", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-13T11:15:09.830", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…