fkie_cve-2021-33710
Vulnerability from fkie_nvd
Published
2021-07-13 11:15
Modified
2024-11-21 06:09
Severity ?
Summary
A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | teamcenter_active_workspace | * | |
| siemens | teamcenter_active_workspace | * | |
| siemens | teamcenter_active_workspace | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E2BB7B04-DD2F-42A8-89ED-0A014C768061",
"versionEndExcluding": "4.3.9",
"versionStartIncluding": "4.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3752E0F7-4A3C-411B-9469-443D8C815629",
"versionEndExcluding": "5.0.7",
"versionStartIncluding": "5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4785E6FA-C094-49FD-BF8E-6E41EFF14467",
"versionEndExcluding": "5.1.4",
"versionStartIncluding": "5.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions \u003c V4.3.9), Teamcenter Active Workspace V5.0 (All versions \u003c V5.0.7), Teamcenter Active Workspace V5.1 (All versions \u003c V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Teamcenter Active Workspace versiones V4 (Todas las versiones anteriores a V4.3.9), Teamcenter Active Workspace versiones V5.0 (Todas las versiones anteriores a V5.0.7), Teamcenter Active Workspace versiones V5.1 (Todas las versiones anteriores a V5.1.4). Se presenta una vulnerabilidad de tipo cross-site scripting (XSS) reflejado en la interfaz web de los dispositivos afectados que podr\u00eda permitir a un atacante ejecutar c\u00f3digo JavaScript malicioso enga\u00f1ando a usuarios para que accedan a un enlace malicioso"
}
],
"id": "CVE-2021-33710",
"lastModified": "2024-11-21T06:09:25.350",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-07-13T11:15:09.830",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…