CVE-2021-33710 (GCVE-0-2021-33710)
Vulnerability from cvelistv5
Published
2021-07-13 11:03
Modified
2024-08-03 23:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link.
References
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Siemens | Teamcenter Active Workspace V4 |
Version: All versions < V4.3.9 |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:58:22.790Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Teamcenter Active Workspace V4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3.9" } ] }, { "product": "Teamcenter Active Workspace V5.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.0.7" } ] }, { "product": "Teamcenter Active Workspace V5.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions \u003c V4.3.9), Teamcenter Active Workspace V5.0 (All versions \u003c V5.0.7), Teamcenter Active Workspace V5.1 (All versions \u003c V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-13T11:03:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-33710", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Teamcenter Active Workspace V4", "version": { "version_data": [ { "version_value": "All versions \u003c V4.3.9" } ] } }, { "product_name": "Teamcenter Active Workspace V5.0", "version": { "version_data": [ { "version_value": "All versions \u003c V5.0.7" } ] } }, { "product_name": "Teamcenter Active Workspace V5.1", "version": { "version_data": [ { "version_value": "All versions \u003c V5.1.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions \u003c V4.3.9), Teamcenter Active Workspace V5.0 (All versions \u003c V5.0.7), Teamcenter Active Workspace V5.1 (All versions \u003c V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-33710", "datePublished": "2021-07-13T11:03:01", "dateReserved": "2021-05-28T00:00:00", "dateUpdated": "2024-08-03T23:58:22.790Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-33710\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-07-13T11:15:09.830\",\"lastModified\":\"2024-11-21T06:09:25.350\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions \u003c V4.3.9), Teamcenter Active Workspace V5.0 (All versions \u003c V5.0.7), Teamcenter Active Workspace V5.1 (All versions \u003c V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Teamcenter Active Workspace versiones V4 (Todas las versiones anteriores a V4.3.9), Teamcenter Active Workspace versiones V5.0 (Todas las versiones anteriores a V5.0.7), Teamcenter Active Workspace versiones V5.1 (Todas las versiones anteriores a V5.1.4). Se presenta una vulnerabilidad de tipo cross-site scripting (XSS) reflejado en la interfaz web de los dispositivos afectados que podr\u00eda permitir a un atacante ejecutar c\u00f3digo JavaScript malicioso enga\u00f1ando a usuarios para que accedan a un enlace malicioso\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.0.0\",\"versionEndExcluding\":\"4.3.9\",\"matchCriteriaId\":\"E2BB7B04-DD2F-42A8-89ED-0A014C768061\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.0.0\",\"versionEndExcluding\":\"5.0.7\",\"matchCriteriaId\":\"3752E0F7-4A3C-411B-9469-443D8C815629\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.1.0\",\"versionEndExcluding\":\"5.1.4\",\"matchCriteriaId\":\"4785E6FA-C094-49FD-BF8E-6E41EFF14467\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…