FKIE_CVE-2021-22681

Vulnerability from fkie_nvd - Published: 2021-03-03 18:15 - Updated: 2026-06-17 03:37
Summary
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "Rockwell Automation Studio 5000 Logix Designer, RSLogix 5000, Logix Controllers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "RSLogix 5000 Versions 16 through 20"
            },
            {
              "status": "affected",
              "version": "Studio 5000 Logix Designer: Versions 21 and later"
            },
            {
              "status": "affected",
              "version": "CompactLogix 1768, 1769, 5370, 5380, 5480"
            },
            {
              "status": "affected",
              "version": "ControlLogix 5550, 5560, 5570, 5580"
            },
            {
              "status": "affected",
              "version": "DriveLogix 5560, 5730, 1794-L34"
            },
            {
              "status": "affected",
              "version": "Compact GuardLogix 5370, 5380"
            },
            {
              "status": "affected",
              "version": "GuardLogix 5570, 5580"
            },
            {
              "status": "affected",
              "version": "SoftLogix 5800"
            }
          ]
        }
      ],
      "source": "ics-cert@hq.dhs.gov"
    }
  ],
  "cisaActionDue": "2026-03-26",
  "cisaExploitAdd": "2026-03-05",
  "cisaRequiredAction": "Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.",
  "cisaVulnerabilityName": "Rockwell Multiple Products Insufficient Protected Credentials Vulnerability",
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6755FCF6-4A0C-478A-AEFF-54E35C45149D",
              "versionStartIncluding": "2.10",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04C30129-3F03-4486-B181-EBDE29751372",
              "versionEndIncluding": "20",
              "versionStartIncluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C840463-A11F-43A0-AA45-1AC810713AB6",
              "versionStartIncluding": "21.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5370:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F951670-AF4D-4429-8BC1-79BDEF83B2C3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62414E65-73C7-4172-B7BF-F40A66AFBB90",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_1768:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E5F100A-C8A3-49F2-B1D2-411432472B6B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_1769:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A690BC-4D7C-4B83-A9F6-F860445028A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5370:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E12ADAE3-97B1-48BC-BE69-ED75667C1886",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80F4F5BE-07DF-402A-BF98-34FBA6A11968",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5550:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "13EE2216-F25F-44AB-A167-4EEA153C8F8D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5560:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA25FF8D-51C5-4928-9B90-E4BD1476F50B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5570:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "482E2CD6-D484-486C-92F4-18432D107E30",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:drivelogix_1794-l34:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A75A0FD-C337-4264-B1E4-96701851D6FA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:drivelogix_5560:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFDAAA77-6964-44FC-9FFB-ECDF71665965",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:drivelogix_5730:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E185C3-17CA-4E3F-863B-9F906C5C59EA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5570:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "321AE938-192A-4342-8608-ADC81F0B6582",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "006B7683-9FDF-4748-BA28-2EA22613E092",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:softlogix_5800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDAB7B6D-CCAC-460B-8A88-3397A2397078",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800."
    },
    {
      "lang": "es",
      "value": "Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores, y RSLogix 5000 versiones 16 hasta 20, usan una clave para verificar que los controladores Logix se est\u00e9n comunicando con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580;\u0026#xa0;DriveLogix 5560, 5730, 1794-L34;\u0026#xa0;Compact GuardLogix 5370, 5380;\u0026#xa0;GuardLogix 5570, 5580;\u0026#xa0;SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores y RSLogix 5000: Versiones 16 hasta 20, son vulnerables porque un atacante no autenticado podr\u00eda pasar por alto este mecanismo de comprobaci\u00f3n y autenticarse con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550 , 5560, 5570, 5580;\u0026#xa0;DriveLogix 5560, 5730, 1794-L34;\u0026#xa0;Compact GuardLogix 5370, 5380;\u0026#xa0;GuardLogix 5570, 5580;\u0026#xa0;SoftLogix 5800"
    }
  ],
  "id": "CVE-2021-22681",
  "lastModified": "2026-06-17T03:37:34.183",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2021-22681",
          "options": [
            {
              "exploitation": "active"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2026-03-05T00:00:00+00:00",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2021-03-03T18:15:14.643",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-22681"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…