A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device.
References
▼ | URL | Tags | |
---|---|---|---|
cybersecurity@se.com | http://www.securityfocus.com/bid/105970 | Third Party Advisory, VDB Entry | |
cybersecurity@se.com | https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/ | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105970 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/ | Mitigation, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | somachine_basic | * | |
schneider-electric | modicon_m221 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:somachine_basic:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BCEA269-6242-41FD-B141-F72CAFC8F114", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*", "matchCriteriaId": "BB0D83F4-B718-47AB-AFB8-B576CB138AAC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device." }, { "lang": "es", "value": "Existe una vulnerabilidad de verificaci\u00f3n insuficiente de autenticidad de datos (CWE-345) en Modicon Modicon M221, todas las versiones, lo que podr\u00eda provocar un cambio en la configuraci\u00f3n IPv4 (direcci\u00f3n IP, m\u00e1scara y puerta de enlace) al conectarse remotamente al dispositivo." } ], "id": "CVE-2018-7798", "lastModified": "2024-11-21T04:12:45.347", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 4.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-11-02T17:29:00.680", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105970" }, { "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105970" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-345" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…