CVE-2026-8033 (GCVE-0-2026-8033)
Vulnerability from cvelistv5 – Published: 2026-05-06 19:30 – Updated: 2026-05-07 14:59
VLAI?
Title
PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure
Summary
A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| PicoTronica | e-Clinic Healthcare System ECHS |
Affected:
5.7
Unaffected: 5.7.1 |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8033",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-06T19:47:19.139182Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-07T14:59:40.518Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Response Header Handler"
],
"product": "e-Clinic Healthcare System ECHS",
"vendor": "PicoTronica",
"versions": [
{
"status": "affected",
"version": "5.7"
},
{
"status": "unaffected",
"version": "5.7.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:OF/RC:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "Information Disclosure",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-06T19:30:16.794Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-361359 | PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/361359"
},
{
"name": "VDB-361359 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/361359/cti"
},
{
"name": "Submit #800793 | PicoTronica e-Clinic Healthcare System (ECHS) v5.7 Information Disclosure",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/800793"
},
{
"tags": [
"exploit"
],
"url": "https://docs.google.com/document/d/1dBJAAYyNpktnOBSCJPJGUMdfjb-Vj3PTy5oNj8RjeQ8/edit?usp=sharing"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-05-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-05-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-05-06T14:22:31.000Z",
"value": "VulDB entry last update"
}
],
"title": "PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-8033",
"datePublished": "2026-05-06T19:30:16.794Z",
"dateReserved": "2026-05-06T12:17:17.895Z",
"dateUpdated": "2026-05-07T14:59:40.518Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-8033",
"date": "2026-05-07",
"epss": "0.0003",
"percentile": "0.08561"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2026-8033\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2026-05-06T20:16:36.360\",\"lastModified\":\"2026-05-07T14:08:07.340\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"},{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"references\":[{\"url\":\"https://docs.google.com/document/d/1dBJAAYyNpktnOBSCJPJGUMdfjb-Vj3PTy5oNj8RjeQ8/edit?usp=sharing\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/submit/800793\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/vuln/361359\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/vuln/361359/cti\",\"source\":\"cna@vuldb.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-8033\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-05-06T19:47:19.139182Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-05-06T19:47:22.880Z\"}}], \"cna\": {\"title\": \"PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure\", \"credits\": [{\"lang\": \"en\", \"type\": \"coordinator\", \"value\": \"VulDB CNA Team\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 6.9, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 5, \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:OF/RC:C\"}}], \"affected\": [{\"vendor\": \"PicoTronica\", \"modules\": [\"Response Header Handler\"], \"product\": \"e-Clinic Healthcare System ECHS\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.7\"}, {\"status\": \"unaffected\", \"version\": \"5.7.1\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2026-05-06T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2026-05-06T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2026-05-06T14:22:31.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/vuln/361359\", \"name\": \"VDB-361359 | PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure\", \"tags\": [\"vdb-entry\"]}, {\"url\": \"https://vuldb.com/vuln/361359/cti\", \"name\": \"VDB-361359 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/submit/800793\", \"name\": \"Submit #800793 | PicoTronica e-Clinic Healthcare System (ECHS) v5.7 Information Disclosure\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://docs.google.com/document/d/1dBJAAYyNpktnOBSCJPJGUMdfjb-Vj3PTy5oNj8RjeQ8/edit?usp=sharing\", \"tags\": [\"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-200\", \"description\": \"Information Disclosure\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"Improper Access Controls\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2026-05-06T19:30:16.794Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-8033\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-05-07T14:59:40.518Z\", \"dateReserved\": \"2026-05-06T12:17:17.895Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2026-05-06T19:30:16.794Z\", \"assignerShortName\": \"VulDB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…