CVE-2026-69200 (GCVE-0-2026-69200)
Vulnerability from cvelistv5 – Published: 2026-09-16 16:15 – Updated: 2026-09-16 16:15
VLAI
EPSS
VEX
Title
node-opcua: Prototype Pollution via internal `fieldsToJson()` implementation (Related to CVE-2024-57086)
Summary
node-opcua is an OPC UA implementation for TypeScript and Node.js. Prior to node-opcua-client 2.145.0, the internal fieldsToJson method in packages/node-opcua-client/source/alarms_and_conditions/client_alarm.ts directly assigns unsanitized field names and allows a __proto__.pollutedKey path to modify Object.prototype. Successful exploitation requires an application to expose attacker-controlled event fields to fieldsToJson and may cause denial of service or application logic corruption. This vulnerability is fixed in 2.145.0.
Severity
CWE
- CWE-1321 - Improperly Controlled Modification of Object Prototype Attributes ('Prototype Pollution')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/node-opcua/node-opcua/security… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| node-opcua | node-opcua |
Affected:
< 2.145.0
|
guessed |
{
"containers": {
"cna": {
"affected": [
{
"product": "node-opcua",
"vendor": "node-opcua",
"versions": [
{
"status": "affected",
"version": "\u003c 2.145.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "node-opcua is an OPC UA implementation for TypeScript and Node.js. Prior to node-opcua-client 2.145.0, the internal fieldsToJson method in packages/node-opcua-client/source/alarms_and_conditions/client_alarm.ts directly assigns unsanitized field names and allows a __proto__.pollutedKey path to modify Object.prototype. Successful exploitation requires an application to expose attacker-controlled event fields to fieldsToJson and may cause denial of service or application logic corruption. This vulnerability is fixed in 2.145.0."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1321",
"description": "CWE-1321: Improperly Controlled Modification of Object Prototype Attributes (\u0027Prototype Pollution\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-16T16:15:58.656Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/node-opcua/node-opcua/security/advisories/GHSA-cv5q-7543-48q4",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/node-opcua/node-opcua/security/advisories/GHSA-cv5q-7543-48q4"
}
],
"source": {
"advisory": "GHSA-cv5q-7543-48q4",
"discovery": "UNKNOWN"
},
"title": "node-opcua: Prototype Pollution via internal `fieldsToJson()` implementation (Related to CVE-2024-57086)"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2026-69200",
"datePublished": "2026-09-16T16:15:58.656Z",
"dateReserved": "2026-08-03T16:57:50.124Z",
"dateUpdated": "2026-09-16T16:15:58.656Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-69200",
"date": "2026-09-17",
"epss": "0.00331",
"percentile": "0.26377"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2026-69200\",\"sourceIdentifier\":\"security-advisories@github.com\",\"published\":\"2026-09-16T17:18:01.093\",\"lastModified\":\"2026-09-16T17:18:01.093\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"node-opcua is an OPC UA implementation for TypeScript and Node.js. Prior to node-opcua-client 2.145.0, the internal fieldsToJson method in packages/node-opcua-client/source/alarms_and_conditions/client_alarm.ts directly assigns unsanitized field names and allows a __proto__.pollutedKey path to modify Object.prototype. Successful exploitation requires an application to expose attacker-controlled event fields to fieldsToJson and may cause denial of service or application logic corruption. This vulnerability is fixed in 2.145.0.\"}],\"affected\":[{\"source\":\"security-advisories@github.com\",\"affectedData\":[{\"vendor\":\"node-opcua\",\"product\":\"node-opcua\",\"versions\":[{\"version\":\"\u003c 2.145.0\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-advisories@github.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":3.7,\"baseSeverity\":\"LOW\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.2,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"security-advisories@github.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1321\"}]}],\"references\":[{\"url\":\"https://github.com/node-opcua/node-opcua/security/advisories/GHSA-cv5q-7543-48q4\",\"source\":\"security-advisories@github.com\"}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…