CVE-2026-35074 (GCVE-0-2026-35074)

Vulnerability from cvelistv5 – Published: 2026-04-17 10:57 – Updated: 2026-04-17 10:57
VLAI?
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS Command Injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Domain Affected: 0 , < 8.6.1.10, 8.7.0.1 or later (semver)
Affected: 0 , < 8.3.1.30 or later (semver)
Affected: 0 , < 7.13.1.70 or later (semver)
Affected: 0 , < 2.7.9 with DD OS 8.3.1.30 (semver)
Create a notification for this product.
Date Public ?
2026-04-15 18:30
Show details on NVD website

{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Domain",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.6.1.10, 8.7.0.1 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "8.3.1.30 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "7.13.1.70 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.9 with DD OS 8.3.1.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2026-04-15T18:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS Command Injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges."
            }
          ],
          "value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS Command Injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-17T10:57:20.150Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000450699/dsa-2026-060-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2026-35074",
    "datePublished": "2026-04-17T10:57:20.150Z",
    "dateReserved": "2026-04-01T05:04:41.955Z",
    "dateUpdated": "2026-04-17T10:57:20.150Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-35074",
      "date": "2026-04-17",
      "epss": "0.00042",
      "percentile": "0.12517"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-35074\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2026-04-17T11:16:10.737\",\"lastModified\":\"2026-04-17T15:07:18.050\",\"vulnStatus\":\"Undergoing Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS Command Injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000450699/dsa-2026-060-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities\",\"source\":\"security_alert@emc.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…