GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2026-17063 (GCVE-0-2026-17063)

Vulnerability from cvelistv5 – Published: 2026-08-19 19:08 – Updated: 2026-08-20 15:21
VLAI
Title
Power System Incorrect Authorization
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 14:19 UTC
CWE
  • CWE-863 - Incorrect Authorization
Assigner
References
URL Tags
https://www.ibm.com/support/pages/node/7283219 vendor-advisorypatch
Impacted products
Vendor Product Version CPE status
IBM Power Systems Firmware Affected: FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver)
Affected: FW1060.00 , ≤ FW1060.80 (semver)
    cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*
    cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-17063",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-20T14:19:14.839242Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-20T15:21:43.570Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
            "cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*"
          ],
          "product": "Power Systems Firmware",
          "vendor": "IBM",
          "versions": [
            {
              "status": "affected",
              "version": "FW1120.00"
            },
            {
              "lessThanOrEqual": "FW1110.30",
              "status": "affected",
              "version": "FW1110.00",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "FW1060.80",
              "status": "affected",
              "version": "FW1060.00",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact.\u003c/p\u003e"
            }
          ],
          "value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.9,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863 Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-19T19:08:30.320Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://www.ibm.com/support/pages/node/7283219"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eCustomers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\u003cbr/\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1180 (9080-HEU)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\u003cbr/\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1122 (9824-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1124 (9824-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1122s (9824-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1114 (9824-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1122 (9856-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1124 (9856-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1150 (9043-MRU)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1112 (9242-21B, 9242-21T)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cbr/\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003cbr/\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1080 (9080-HEX)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install\u00a0 FW1060.81(1060_191), or newer to remediate this vulnerability.\u003cbr/\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1022 (9105-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1024 (9105-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1022s (9105-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1014 (9105-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1022 (9786-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1024 (9786-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1050 (9043-MRX)\u003c/li\u003e\u003cli\u003eIBM Power System S1012 (9028-21B)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cem\u003eThe images mentioned above can be located at IBM Fix Central : \u003c/em\u003e\u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"noopener noreferrer nofollow\"\u003e\u003cem\u003ehttps://www.ibm.com/support/fixcentral/\u003c/em\u003e\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\nPower 11\n\n  *  IBM Power System E1180 (9080-HEU)\n\n\nCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\nPower 11\n\n  *  IBM Power System S1122 (9824-22A)\n  *  IBM Power System S1124 (9824-42A)\n  *  IBM Power System S1122s (9824-22B)\n  *  IBM Power System S1114 (9824-41B)\n  *  IBM Power System L1122 (9856-22H)\n  *  IBM Power System L1124 (9856-42H)\n  *  IBM Power System E1150 (9043-MRU)\n\n\nCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\n\n\n\nPower 11\n\n  *  IBM Power System S1112 (9242-21B, 9242-21T)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\nPower 10\n\n  *  IBM Power System E1080 (9080-HEX)\n\n\nCustomers with the products below should install\u00a0 FW1060.81(1060_191), or newer to remediate this vulnerability.\nPower 10\n\n  *  IBM Power System S1022 (9105-22A)\n  *  IBM Power System S1024 (9105-42A)\n  *  IBM Power System S1022s (9105-22B)\n  *  IBM Power System S1014 (9105-41B)\n  *  IBM Power System L1022 (9786-22H)\n  *  IBM Power System L1024 (9786-42H)\n  *  IBM Power System E1050 (9043-MRX)\n  *  IBM Power System S1012 (9028-21B)\n\n\nThe images mentioned above can be located at IBM Fix Central :  https://www.ibm.com/support/fixcentral/ https://www.ibm.com/support/fixcentral/"
        }
      ],
      "title": "Power System Incorrect Authorization"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2026-17063",
    "datePublished": "2026-08-19T19:08:30.320Z",
    "dateReserved": "2026-07-24T13:52:40.170Z",
    "dateUpdated": "2026-08-20T15:21:43.570Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-17063",
      "date": "2026-09-17",
      "epss": "0.00117",
      "percentile": "0.01861"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
                  "cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
                  "cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
                  "cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
                  "cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*"
                ],
                "product": "Power Systems Firmware",
                "vendor": "IBM",
                "versions": [
                  {
                    "status": "affected",
                    "version": "FW1120.00"
                  },
                  {
                    "lessThanOrEqual": "FW1110.30",
                    "status": "affected",
                    "version": "FW1110.00",
                    "versionType": "semver"
                  },
                  {
                    "lessThanOrEqual": "FW1060.80",
                    "status": "affected",
                    "version": "FW1060.00",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "psirt@us.ibm.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1122_\\(9824-22a\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C016EFBA-A371-4264-A823-A7635D39F6D9",
                    "versionEndExcluding": "fw1110.31",
                    "versionStartIncluding": "fw1110.00",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1122_\\(9824-22a\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B8707806-84E4-442B-A29F-7BF44514F8DA",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1122_\\(9824-22a\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "96C2DEDC-012D-4B9F-B9DF-344A49B67E46",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1124_\\(9824-42a\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6B512BF5-7D6B-45EA-97B8-F22B63A62270",
                    "versionEndExcluding": "fw1110.31",
                    "versionStartIncluding": "fw1110.00",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1124_\\(9824-42a\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "25BCA648-5FF1-4B90-98ED-23E5BB217465",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1124_\\(9824-42a\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3F51514A-8E29-42D1-B874-838F8A0869D2",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1122s_\\(9824-22b\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BC8256E1-574D-4666-BE1B-45977348AC86",
                    "versionEndExcluding": "fw1110.31",
                    "versionStartIncluding": "fw1110.00",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1122s_\\(9824-22b\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2165EAA9-EDC9-4010-9D31-294F9414A9E6",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1122s_\\(9824-22b\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "26E1E16B-8F95-46EC-BAA0-0A53F332292B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1114_\\(9824-41b\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3F8C1054-A539-468C-9A5F-E6E686C6CE8A",
                    "versionEndExcluding": "fw1110.31",
                    "versionStartIncluding": "fw1110.00",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1114_\\(9824-41b\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "085F1C27-D806-4E4B-A44A-BB3C056CFCF7",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1114_\\(9824-41b\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8688E552-BE38-4EB9-8514-D7060C548C39",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_l1122_\\(9856-22h\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "37868E6E-7759-4CCB-995E-BDB7F61F6818",
                    "versionEndExcluding": "fw1110.31",
                    "versionStartIncluding": "fw1110.00",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_l1122_\\(9856-22h\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "50916B93-7340-4344-AF34-91836ABE508F",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_l1122_\\(9856-22h\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3C8998E4-5EA9-4C7E-BF59-644CB78D00D2",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_l1124_\\(9856-42h\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9F0FE92C-3510-475A-8D02-ED17ADD87CD0",
                    "versionEndExcluding": "fw1110.31",
                    "versionStartIncluding": "fw1110.00",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_l1124_\\(9856-42h\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FECCD687-64E7-45B4-BCB7-AEF25164D049",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_l1124_\\(9856-42h\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3FB6FA2C-70A5-4F19-B64B-7502D20CFE5C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_e1150_\\(9043-mru\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DC4CCBFC-3120-475D-BF75-025C04E41B91",
                    "versionEndExcluding": "fw1110.31",
                    "versionStartIncluding": "fw1110.00",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_e1150_\\(9043-mru\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BE428FBB-4DDC-4E05-A5C3-F37BE9395723",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_e1150_\\(9043-mru\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AC9D9EFF-1E92-4894-9976-001227F78869",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1112_\\(9242-21b\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6505E499-E766-451D-9996-1668BE53AAF8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1112_\\(9242-21b\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B3F5100A-FE2A-412C-9B57-B616B97B1142",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1112_\\(9242-21t\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "109DE27E-5F87-4BD0-8C48-F72A1C2AD55D",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1112_\\(9242-21t\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EA825307-2083-4264-8E8B-798661285261",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_e1080_\\(9080-hex\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AA6D803F-DD5C-49A7-BE93-68981C124C69",
                    "versionEndExcluding": "fw1060.81",
                    "versionStartIncluding": "fw1060.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_e1080_\\(9080-hex\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DF85251B-E02C-4293-98F0-D331BF51CAC4",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1022_\\(9105-22a\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0BB54554-C9DC-4072-A205-EA9DD4E15688",
                    "versionEndExcluding": "fw1060.81",
                    "versionStartIncluding": "fw1060.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1022_\\(9105-22a\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E3E15C41-9CBD-4F66-A176-07B3E9BBD81D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1024_\\(9105-42a\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FA4B835D-CEAB-422B-9F38-F63AF84396C3",
                    "versionEndExcluding": "fw1060.81",
                    "versionStartIncluding": "fw1060.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1024_\\(9105-42a\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E49EE658-B8AE-48F7-A765-92BA3A630AA0",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1022s_\\(9105-22b\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "51C2576F-E4DD-4002-9E41-CF89F92E2064",
                    "versionEndExcluding": "fw1060.81",
                    "versionStartIncluding": "fw1060.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1022s_\\(9105-22b\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "564A665A-7B94-40CE-A4D9-CDD0CCF52B2E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1014_\\(9105-41b\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "41572D5A-C3A2-4294-9AF9-D4824675B4A3",
                    "versionEndExcluding": "fw1060.81",
                    "versionStartIncluding": "fw1060.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1014_\\(9105-41b\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "ECD54B80-5754-4C19-AE0C-F539DEF96DCB",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_l1022_\\(9786-22h\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EEBFE6F7-E6D8-47AC-B011-751FB9BC3D50",
                    "versionEndExcluding": "fw1060.81",
                    "versionStartIncluding": "fw1060.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_l1022_\\(9786-22h\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B2C09090-C18F-464A-8DEF-E23B5990E2A4",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_l1024_\\(9786-42h\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D6EA818B-DC65-4F2D-9FC9-C610FFABE3DD",
                    "versionEndExcluding": "fw1060.81",
                    "versionStartIncluding": "fw1060.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_l1024_\\(9786-42h\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0170400B-89A7-4B44-9AA7-9A168C9CAE9C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_e1050_\\(9043-mrx\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2F04E3C9-94C6-42B0-9FBD-4AC5FEF42A1F",
                    "versionEndExcluding": "fw1060.81",
                    "versionStartIncluding": "fw1060.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_e1050_\\(9043-mrx\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "061D193E-84BC-4DE7-96C4-B75D11769ED5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_s1012_\\(9028-21b\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0524365D-8379-4B10-B9C5-FF80EE84BA27",
                    "versionEndExcluding": "fw1060.81",
                    "versionStartIncluding": "fw1060.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_s1012_\\(9028-21b\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7BED85F2-8CCB-417C-A739-23828966A036",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E8049F52-227B-4CCA-B059-5821F9B41C95",
                    "versionEndExcluding": "fw1110.31",
                    "versionStartIncluding": "fw1110.00",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ibm:power_system_e1180_\\(9080-heu\\)_firmware:fw1120.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F518B3DD-3F25-4581-9103-6CD4D8DA54C7",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ibm:power_system_e1180_\\(9080-heu\\):-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8BD4FC49-8120-4D4B-906A-1B6FA6B30FA2",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact."
          }
        ],
        "id": "CVE-2026-17063",
        "lastModified": "2026-08-25T12:13:04.073",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.9,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.5,
              "impactScore": 5.8,
              "source": "psirt@us.ibm.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-17063",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-20T14:19:14.839242Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-08-19T20:17:12.307",
        "references": [
          {
            "source": "psirt@us.ibm.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.ibm.com/support/pages/node/7283219"
          }
        ],
        "sourceIdentifier": "psirt@us.ibm.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-863"
              }
            ],
            "source": "psirt@us.ibm.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-17063",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-20T14:19:14.839242Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-20T14:19:16.512Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
                "cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
                "cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
                "cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
                "cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*"
              ],
              "product": "Power Systems Firmware",
              "vendor": "IBM",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW1120.00"
                },
                {
                  "lessThanOrEqual": "FW1110.30",
                  "status": "affected",
                  "version": "FW1110.00",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "FW1060.80",
                  "status": "affected",
                  "version": "FW1060.00",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact.\u003c/p\u003e"
                }
              ],
              "value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.9,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-19T19:08:30.320Z",
            "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
            "shortName": "ibm"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory",
                "patch"
              ],
              "url": "https://www.ibm.com/support/pages/node/7283219"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eCustomers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\u003cbr/\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1180 (9080-HEU)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\u003cbr/\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1122 (9824-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1124 (9824-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1122s (9824-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1114 (9824-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1122 (9856-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1124 (9856-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1150 (9043-MRU)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1112 (9242-21B, 9242-21T)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cbr/\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003cbr/\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1080 (9080-HEX)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eCustomers with the products below should install\u00a0 FW1060.81(1060_191), or newer to remediate this vulnerability.\u003cbr/\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1022 (9105-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1024 (9105-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1022s (9105-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1014 (9105-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1022 (9786-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1024 (9786-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1050 (9043-MRX)\u003c/li\u003e\u003cli\u003eIBM Power System S1012 (9028-21B)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cem\u003eThe images mentioned above can be located at IBM Fix Central : \u003c/em\u003e\u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"noopener noreferrer nofollow\"\u003e\u003cem\u003ehttps://www.ibm.com/support/fixcentral/\u003c/em\u003e\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e"
                }
              ],
              "value": "Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\nPower 11\n\n  *  IBM Power System E1180 (9080-HEU)\n\n\nCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\nPower 11\n\n  *  IBM Power System S1122 (9824-22A)\n  *  IBM Power System S1124 (9824-42A)\n  *  IBM Power System S1122s (9824-22B)\n  *  IBM Power System S1114 (9824-41B)\n  *  IBM Power System L1122 (9856-22H)\n  *  IBM Power System L1124 (9856-42H)\n  *  IBM Power System E1150 (9043-MRU)\n\n\nCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\n\n\n\nPower 11\n\n  *  IBM Power System S1112 (9242-21B, 9242-21T)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\nPower 10\n\n  *  IBM Power System E1080 (9080-HEX)\n\n\nCustomers with the products below should install\u00a0 FW1060.81(1060_191), or newer to remediate this vulnerability.\nPower 10\n\n  *  IBM Power System S1022 (9105-22A)\n  *  IBM Power System S1024 (9105-42A)\n  *  IBM Power System S1022s (9105-22B)\n  *  IBM Power System S1014 (9105-41B)\n  *  IBM Power System L1022 (9786-22H)\n  *  IBM Power System L1024 (9786-42H)\n  *  IBM Power System E1050 (9043-MRX)\n  *  IBM Power System S1012 (9028-21B)\n\n\nThe images mentioned above can be located at IBM Fix Central :  https://www.ibm.com/support/fixcentral/ https://www.ibm.com/support/fixcentral/"
            }
          ],
          "title": "Power System Incorrect Authorization"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "assignerShortName": "ibm",
        "cveId": "CVE-2026-17063",
        "datePublished": "2026-08-19T19:08:30.320Z",
        "dateReserved": "2026-07-24T13:52:40.170Z",
        "dateUpdated": "2026-08-20T15:21:43.570Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…