CVE-2025-0498 (GCVE-0-2025-0498)
Vulnerability from cvelistv5
Published
2025-01-30 17:36
Modified
2025-02-12 19:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-522 - Insufficiently Protected Credentials
Summary
A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to insecure storage of FactoryTalk® Security user tokens, which could allow a threat actor to steal a token and, impersonate another user.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Rockwell Automation | FactoryTalk® AssetCentre |
Version: All prior to V15.00.001 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0498",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-30T19:52:41.177477Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T19:51:11.392Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae AssetCentre",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "All prior to V15.00.001"
}
]
}
],
"datePublic": "2025-01-30T17:32:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk\u00ae AssetCentre. The vulnerability exists due to insecure storage of FactoryTalk\u00ae Security user tokens, which could allow a threat actor to steal a token and, impersonate another user.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk\u00ae AssetCentre. The vulnerability exists due to insecure storage of FactoryTalk\u00ae Security user tokens, which could allow a threat actor to steal a token and, impersonate another user."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T17:37:30.249Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1721.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Corrected in:\u003cbr\u003e\u003cbr\u003e\n\n\u003cp\u003eV11, V12, and V13 (patch available)\u003c/p\u003e\u003cp\u003eV15.00.01 and later\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Corrected in:\n\n\n\nV11, V12, and V13 (patch available)\n\nV15.00.01 and later"
}
],
"source": {
"advisory": "SD1721",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation FactoryTalk\u00ae AssetCentre Data Exposure Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-0498",
"datePublished": "2025-01-30T17:36:12.542Z",
"dateReserved": "2025-01-15T15:46:08.098Z",
"dateUpdated": "2025-02-12T19:51:11.392Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-0498\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2025-01-30T18:15:33.253\",\"lastModified\":\"2025-11-04T17:20:55.537\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk\u00ae AssetCentre. The vulnerability exists due to insecure storage of FactoryTalk\u00ae Security user tokens, which could allow a threat actor to steal a token and, impersonate another user.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de exposici\u00f3n de datos en todas las versiones anteriores a la V15.00.001 de Rockwell Automation FactoryTalk\u00ae AssetCentre. La vulnerabilidad existe debido al almacenamiento inseguro de tokens de usuario de FactoryTalk\u00ae Security, lo que podr\u00eda permitir que un actor de amenazas robe un token y se haga pasar por otro usuario.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.0,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"PASSIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-522\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_assetcentre:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.00.01\",\"matchCriteriaId\":\"D14B0A41-7FA8-4779-9F64-0611B0EFCE62\"}]}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1721.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"cna\": {\"affected\": [{\"defaultStatus\": \"unaffected\", \"product\": \"FactoryTalk\\u00ae AssetCentre\", \"vendor\": \"Rockwell Automation\", \"versions\": [{\"status\": \"affected\", \"version\": \"All prior to V15.00.001\"}]}], \"datePublic\": \"2025-01-30T17:32:00.000Z\", \"descriptions\": [{\"lang\": \"en\", \"supportingMedia\": [{\"base64\": false, \"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eA data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk\\u00ae AssetCentre. The vulnerability exists due to insecure storage of FactoryTalk\\u00ae Security user tokens, which could allow a threat actor to steal a token and, impersonate another user.\u003c/span\u003e\\n\\n\u003cbr\u003e\"}], \"value\": \"A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk\\u00ae AssetCentre. The vulnerability exists due to insecure storage of FactoryTalk\\u00ae Security user tokens, which could allow a threat actor to steal a token and, impersonate another user.\"}], \"metrics\": [{\"cvssV4_0\": {\"Automatable\": \"NOT_DEFINED\", \"Recovery\": \"NOT_DEFINED\", \"Safety\": \"NOT_DEFINED\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"attackVector\": \"LOCAL\", \"baseScore\": 7, \"baseSeverity\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"providerUrgency\": \"NOT_DEFINED\", \"subAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"userInteraction\": \"PASSIVE\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"version\": \"4.0\", \"vulnAvailabilityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"format\": \"CVSS\", \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"problemTypes\": [{\"descriptions\": [{\"cweId\": \"CWE-522\", \"description\": \"CWE-522 Insufficiently Protected Credentials\", \"lang\": \"en\", \"type\": \"CWE\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2025-01-30T17:37:30.249Z\"}, \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1721.html\"}], \"solutions\": [{\"lang\": \"en\", \"supportingMedia\": [{\"base64\": false, \"type\": \"text/html\", \"value\": \"Corrected in:\u003cbr\u003e\u003cbr\u003e\\n\\n\u003cp\u003eV11, V12, and V13 (patch available)\u003c/p\u003e\u003cp\u003eV15.00.01 and later\u003c/p\u003e\\n\\n\u003cbr\u003e\"}], \"value\": \"Corrected in:\\n\\n\\n\\nV11, V12, and V13 (patch available)\\n\\nV15.00.01 and later\"}], \"source\": {\"advisory\": \"SD1721\", \"discovery\": \"INTERNAL\"}, \"title\": \"Rockwell Automation FactoryTalk\\u00ae AssetCentre Data Exposure Vulnerability\", \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}}, \"adp\": [{\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-0498\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-30T19:52:41.177477Z\"}}}], \"providerMetadata\": {\"shortName\": \"CISA-ADP\", \"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"dateUpdated\": \"2025-02-12T19:44:34.165Z\"}, \"title\": \"CISA ADP Vulnrichment\"}]}",
"cveMetadata": "{\"cveId\": \"CVE-2025-0498\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"Rockwell\", \"dateReserved\": \"2025-01-15T15:46:08.098Z\", \"datePublished\": \"2025-01-30T17:36:12.542Z\", \"dateUpdated\": \"2025-01-30T17:37:30.249Z\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…