CVE-2024-56334 (GCVE-0-2024-56334)
Vulnerability from cvelistv5 – Published: 2024-12-20 20:10 – Updated: 2024-12-24 16:32
VLAI
EPSS
VEX
Title
Command injection vulnerability in getWindowsIEEE8021x (SSID) function in systeminformation
Summary
systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
Severity
7.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-24 16:32 UTC
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://github.com/sebhildebrandt/systeminformati… | x_refsource_CONFIRM |
| https://github.com/sebhildebrandt/systeminformati… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| sebhildebrandt | systeminformation |
Affected:
< 5.23.7
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-56334",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-24T16:32:16.418664Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-24T16:32:35.731Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "systeminformation",
"vendor": "sebhildebrandt",
"versions": [
{
"status": "affected",
"version": "\u003c 5.23.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-20T20:10:12.578Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
},
{
"name": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41"
}
],
"source": {
"advisory": "GHSA-cvv5-9h9w-qp2m",
"discovery": "UNKNOWN"
},
"title": "Command injection vulnerability in getWindowsIEEE8021x (SSID) function in systeminformation"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2024-56334",
"datePublished": "2024-12-20T20:10:12.578Z",
"dateReserved": "2024-12-19T18:39:53.612Z",
"dateUpdated": "2024-12-24T16:32:35.731Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-56334",
"date": "2026-09-17",
"epss": "0.00704",
"percentile": "0.51678"
},
"fkie_nvd": {
"descriptions": [
{
"lang": "en",
"value": "systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
},
{
"lang": "es",
"value": "systeminformation es una librer\u00eda de informaci\u00f3n del sistema y del SO para node.js. En las versiones afectadas, los SSID no se desinfectan antes de que se pasen como par\u00e1metro a cmd.exe en la funci\u00f3n `getWindowsIEEE8021x`. Esto significa que el contenido malicioso en el SSID se puede ejecutar como comandos del SO. Esta vulnerabilidad puede permitir a un atacante, seg\u00fan c\u00f3mo se use el paquete, realizar una ejecuci\u00f3n de c\u00f3digo remoto o una escalada de privilegios locales. Este problema se ha solucionado en la versi\u00f3n 5.23.7 y se recomienda a todos los usuarios que actualicen. No se conocen workarounds para esta vulnerabilidad."
}
],
"id": "CVE-2024-56334",
"lastModified": "2024-12-24T17:15:09.760",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "security-advisories@github.com",
"type": "Secondary"
}
]
},
"published": "2024-12-20T21:15:10.080",
"references": [
{
"source": "security-advisories@github.com",
"url": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41"
},
{
"source": "security-advisories@github.com",
"url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
}
],
"sourceIdentifier": "security-advisories@github.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "security-advisories@github.com",
"type": "Secondary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "systeminformation",
"vendor": "sebhildebrandt",
"versions": [
{
"status": "affected",
"version": "\u003c 5.23.7"
}
]
}
],
"source": "security-advisories@github.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
},
{
"lang": "es",
"value": "systeminformation es una librer\u00eda de informaci\u00f3n del sistema y del SO para node.js. En las versiones afectadas, los SSID no se desinfectan antes de que se pasen como par\u00e1metro a cmd.exe en la funci\u00f3n `getWindowsIEEE8021x`. Esto significa que el contenido malicioso en el SSID se puede ejecutar como comandos del SO. Esta vulnerabilidad puede permitir a un atacante, seg\u00fan c\u00f3mo se use el paquete, realizar una ejecuci\u00f3n de c\u00f3digo remoto o una escalada de privilegios locales. Este problema se ha solucionado en la versi\u00f3n 5.23.7 y se recomienda a todos los usuarios que actualicen. No se conocen workarounds para esta vulnerabilidad."
}
],
"id": "CVE-2024-56334",
"lastModified": "2026-06-17T08:12:03.960",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "security-advisories@github.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-56334",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-24T16:32:16.418664Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-12-20T21:15:10.080",
"references": [
{
"source": "security-advisories@github.com",
"url": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41"
},
{
"source": "security-advisories@github.com",
"url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
}
],
"sourceIdentifier": "security-advisories@github.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "security-advisories@github.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"aggregate_severity": "Important",
"current_release_date": "2026-08-17T06:11:39+00:00",
"cve": "CVE-2024-56334",
"id": "CVE-2024-56334",
"initial_release_date": "2024-12-20T20:10:12.578000+00:00",
"product_status:fixed": "2",
"product_status:known_not_affected": "5",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "systeminformation: Command injection vulnerability in getWindowsIEEE8021x (SSID) function in systeminformation",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-56334.json",
"version": "3"
},
"suse_vex": {
"aggregate_severity": "important",
"current_release_date": "2025-02-16T03:54:31Z",
"cve": "CVE-2024-56334",
"id": "CVE-2024-56334",
"initial_release_date": "2024-12-27T00:16:45Z",
"source": "SUSE CSAF VEX",
"status": "interim",
"title": "SUSE CVE CVE-2024-56334",
"url": "https://ftp.suse.com/pub/projects/security/csaf-vex/cve-2024-56334.json",
"version": "5"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-56334",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-24T16:32:16.418664Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-24T16:32:30.447Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "systeminformation",
"vendor": "sebhildebrandt",
"versions": [
{
"status": "affected",
"version": "\u003c 5.23.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-20T20:10:12.578Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
},
{
"name": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41"
}
],
"source": {
"advisory": "GHSA-cvv5-9h9w-qp2m",
"discovery": "UNKNOWN"
},
"title": "Command injection vulnerability in getWindowsIEEE8021x (SSID) function in systeminformation"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2024-56334",
"datePublished": "2024-12-20T20:10:12.578Z",
"dateReserved": "2024-12-19T18:39:53.612Z",
"dateUpdated": "2024-12-24T16:32:35.731Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…