cve-2024-45470
Vulnerability from cvelistv5
Published
2024-10-08 08:40
Modified
2024-12-10 13:53
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
   containers: {
      adp: [
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "tecnomatix_plant_simulation",
                  vendor: "siemens",
                  versions: [
                     {
                        lessThan: "2302.0016",
                        status: "affected",
                        version: "2302.0",
                        versionType: "custom",
                     },
                     {
                        lessThan: "2404.0005",
                        status: "affected",
                        version: "2404.0",
                        versionType: "custom",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-45470",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-10-08T17:58:46.110148Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-10-08T17:59:39.102Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.2",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.2.0.14",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.3",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.3.0.12",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2312",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2312.0008",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2302",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2302.0016",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2404",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2404.0005",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-787",
                     description: "CWE-787: Out-of-bounds Write",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-12-10T13:53:41.482Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-583523.html",
            },
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-645131.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2024-45470",
      datePublished: "2024-10-08T08:40:30.348Z",
      dateReserved: "2024-08-29T11:28:48.106Z",
      dateUpdated: "2024-12-10T13:53:41.482Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      nvd: "{\"cve\":{\"id\":\"CVE-2024-45470\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-10-08T09:15:13.973\",\"lastModified\":\"2024-12-10T14:30:42.990\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\\r\\nThis could allow an attacker to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2302 (todas las versiones anteriores a V2302.0016) y Tecnomatix Plant Simulation V2404 (todas las versiones anteriores a V2404.0005). Las aplicaciones afectadas contienen una vulnerabilidad de escritura fuera de los límites al analizar un archivo WRL especialmente manipulado. Esto podría permitir que un atacante ejecute código en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"PASSIVE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"HIGH\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2302.0016\",\"matchCriteriaId\":\"00AE6AA5-618F-4494-B8D6-2AC25A5DC2F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2303.0000\",\"versionEndExcluding\":\"2404.0005\",\"matchCriteriaId\":\"E84CE123-587E-480C-A6C8-AF7B4AE3ACF2\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-583523.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-645131.html\",\"source\":\"productcert@siemens.com\"}]}}",
      vulnrichment: {
         containers: "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-45470\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-08T17:58:46.110148Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"tecnomatix_plant_simulation\", \"versions\": [{\"status\": \"affected\", \"version\": \"2302.0\", \"lessThan\": \"2302.0016\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"2404.0\", \"lessThan\": \"2404.0005\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-08T17:59:31.454Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V14.2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V14.2.0.14\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V14.3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V14.3.0.12\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V2312\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2312.0008\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Tecnomatix Plant Simulation V2302\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2302.0016\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Tecnomatix Plant Simulation V2404\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2404.0005\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-583523.html\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-645131.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\\r\\nThis could allow an attacker to execute code in the context of the current process.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-787\", \"description\": \"CWE-787: Out-of-bounds Write\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-12-10T13:53:41.482Z\"}}}",
         cveMetadata: "{\"cveId\": \"CVE-2024-45470\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-12-10T13:53:41.482Z\", \"dateReserved\": \"2024-08-29T11:28:48.106Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2024-10-08T08:40:30.348Z\", \"assignerShortName\": \"siemens\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.