GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-3264 (GCVE-0-2024-3264)

Vulnerability from cvelistv5 – Published: 2024-06-24 12:45 – Updated: 2026-06-03 14:16
VLAI
Title
Broken or Risky Cryptographic Algorithm in Mia Technology's Mia-Med Health Aplication
Summary
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation. This issue affects Mia-Med Health Aplication: before 1.0.14.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-26 16:49 UTC
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
References
Impacted products
Vendor Product Version CPE status
Mia Technology Inc. Mia-Med Health Aplication Affected: 0 , < 1.0.14 (custom)
guessed Create a notification for this product.
miateknoloji mia-med Affected: 0 , < 1.0.14 (custom)
    cpe:2.3:a:miateknoloji:mia-med:-:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:miateknoloji:mia-med:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mia-med",
            "vendor": "miateknoloji",
            "versions": [
              {
                "lessThan": "1.0.14",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3264",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T16:49:03.514353Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T18:56:37.905Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:05:08.373Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.usom.gov.tr/bildirim/tr-24-0765"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Mia-Med Health Aplication",
          "vendor": "Mia Technology Inc.",
          "versions": [
            {
              "lessThan": "1.0.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Mustafa An\u0131l YILDIRIM"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.\u003cp\u003eThis issue affects Mia-Med Health Aplication: before 1.0.14.\u003c/p\u003e"
            }
          ],
          "value": "Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.\n\nThis issue affects Mia-Med Health Aplication: before 1.0.14."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-475",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-475 Signature Spoofing by Improper Validation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327 Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-03T14:16:51.216Z",
        "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "shortName": "TR-CERT"
      },
      "references": [
        {
          "tags": [
            "government-resource",
            "broken-link"
          ],
          "url": "https://www.usom.gov.tr/bildirim/tr-24-0765"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0765"
        }
      ],
      "source": {
        "advisory": "TR-24-0765",
        "defect": [
          "TR-24-0765"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Broken or Risky Cryptographic Algorithm in Mia Technology\u0027s Mia-Med Health Aplication",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
    "assignerShortName": "TR-CERT",
    "cveId": "CVE-2024-3264",
    "datePublished": "2024-06-24T12:45:13.204Z",
    "dateReserved": "2024-04-03T12:54:07.773Z",
    "dateUpdated": "2026-06-03T14:16:51.216Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-3264",
      "date": "2026-09-17",
      "epss": "0.00209",
      "percentile": "0.11292"
    },
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.This issue affects Mia-Med Health Aplication: before 1.0.14.\"}, {\"lang\": \"es\", \"value\": \"Uso de una vulnerabilidad de algoritmo criptogr\\u00e1fico roto o riesgoso en Mia Technology Inc. Mia-Med Health Aplication permite la falsificaci\\u00f3n de firmas mediante una validaci\\u00f3n inadecuada. Este problema afecta a Mia-Med Health Aplication: antes de la versi\\u00f3n 1.0.14.\"}]",
      "id": "CVE-2024-3264",
      "lastModified": "2024-11-21T09:29:16.480",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"iletisim@usom.gov.tr\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 1.4}]}",
      "published": "2024-06-24T13:15:11.627",
      "references": "[{\"url\": \"https://www.usom.gov.tr/bildirim/tr-24-0765\", \"source\": \"iletisim@usom.gov.tr\"}, {\"url\": \"https://www.usom.gov.tr/bildirim/tr-24-0765\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "iletisim@usom.gov.tr",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": "[{\"source\": \"iletisim@usom.gov.tr\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-327\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-3264\",\"sourceIdentifier\":\"iletisim@usom.gov.tr\",\"published\":\"2024-06-24T13:15:11.627\",\"lastModified\":\"2026-06-17T07:43:38.780\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.\\n\\nThis issue affects Mia-Med Health Aplication: before 1.0.14.\"},{\"lang\":\"es\",\"value\":\"Uso de una vulnerabilidad de algoritmo criptogr\u00e1fico roto o riesgoso en Mia Technology Inc. Mia-Med Health Aplication permite la falsificaci\u00f3n de firmas mediante una validaci\u00f3n inadecuada. Este problema afecta a Mia-Med Health Aplication: antes de la versi\u00f3n 1.0.14.\"}],\"affected\":[{\"source\":\"iletisim@usom.gov.tr\",\"affectedData\":[{\"vendor\":\"Mia Technology Inc.\",\"product\":\"Mia-Med Health Aplication\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"1.0.14\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"affectedData\":[{\"vendor\":\"miateknoloji\",\"product\":\"mia-med\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:a:miateknoloji:mia-med:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"1.0.14\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"iletisim@usom.gov.tr\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2024-06-26T16:49:03.514353Z\",\"id\":\"CVE-2024-3264\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"yes\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"iletisim@usom.gov.tr\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]}],\"references\":[{\"url\":\"https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0765\",\"source\":\"iletisim@usom.gov.tr\"},{\"url\":\"https://www.usom.gov.tr/bildirim/tr-24-0765\",\"source\":\"iletisim@usom.gov.tr\"},{\"url\":\"https://www.usom.gov.tr/bildirim/tr-24-0765\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "redhat_vex": {
      "current_release_date": "2026-06-03T16:01:55+00:00",
      "cve": "CVE-2024-3264",
      "id": "CVE-2024-3264",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Broken or Risky Cryptographic Algorithm in Mia Technology\u0027s Mia-Med Health Aplication",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-3264.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.usom.gov.tr/bildirim/tr-24-0765\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T20:05:08.373Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-3264\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-06-26T16:49:03.514353Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:miateknoloji:mia-med:-:*:*:*:*:*:*:*\"], \"vendor\": \"miateknoloji\", \"product\": \"mia-med\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.0.14\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-26T18:56:34.106Z\"}}], \"cna\": {\"title\": \"Broken or Risky Cryptographic Algorithm in Mia Technology\u0027s Mia-Med Health Aplication\", \"source\": {\"defect\": [\"TR-24-0765\"], \"advisory\": \"TR-24-0765\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Mustafa An\\u0131l YILDIRIM\"}], \"impacts\": [{\"capecId\": \"CAPEC-475\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-475 Signature Spoofing by Improper Validation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Mia Technology Inc.\", \"product\": \"Mia-Med Health Aplication\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.0.14\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.usom.gov.tr/bildirim/tr-24-0765\", \"tags\": [\"government-resource\", \"broken-link\"]}, {\"url\": \"https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0765\", \"tags\": [\"government-resource\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.\\n\\nThis issue affects Mia-Med Health Aplication: before 1.0.14.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.\u003cp\u003eThis issue affects Mia-Med Health Aplication: before 1.0.14.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-327\", \"description\": \"CWE-327 Use of a Broken or Risky Cryptographic Algorithm\"}]}], \"providerMetadata\": {\"orgId\": \"ca940d4e-fea4-4aa2-9a58-591a58b1ce21\", \"shortName\": \"TR-CERT\", \"dateUpdated\": \"2026-06-03T14:16:51.216Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-3264\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-06-03T14:16:51.216Z\", \"dateReserved\": \"2024-04-03T12:54:07.773Z\", \"assignerOrgId\": \"ca940d4e-fea4-4aa2-9a58-591a58b1ce21\", \"datePublished\": \"2024-06-24T12:45:13.204Z\", \"assignerShortName\": \"TR-CERT\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…