CVE-2024-2895 (GCVE-0-2024-2895)
Vulnerability from cvelistv5 – Published: 2024-03-26 17:31 – Updated: 2024-08-01 19:25
VLAI
EPSS
VEX
Title
Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-05 19:51 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257938 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257938 | signaturepermissions-required |
| https://vuldb.com/?submit.300358 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Tenda | AC7 |
Affected:
15.03.06.44
|
guessed | |
| tenda | ac7_firmware |
Affected:
15.03.06.44
cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2895",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-05T19:51:36.570635Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T19:52:13.147Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:42.160Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257938 | Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257938"
},
{
"name": "VDB-257938 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257938"
},
{
"name": "Submit #300358 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.300358"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC7 15.03.06.44 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formWifiWpsOOB der Datei /goform/WifiWpsOOB. Durch Beeinflussen des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-26T17:31:04.304Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257938 | Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257938"
},
{
"name": "VDB-257938 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257938"
},
{
"name": "Submit #300358 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.300358"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-26T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-26T10:30:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2895",
"datePublished": "2024-03-26T17:31:04.304Z",
"dateReserved": "2024-03-26T09:25:44.223Z",
"dateUpdated": "2024-08-01T19:25:42.160Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-2895",
"date": "2026-09-18",
"epss": "0.01683",
"percentile": "0.75919"
},
"fkie_nvd": {
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Ha sido declarada cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n formWifiWpsOOB del archivo /goform/WifiWpsOOB. La manipulaci\u00f3n del \u00edndice de argumentos conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257938 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"id": "CVE-2024-2895",
"lastModified": "2024-11-21T09:10:46.743",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
},
"published": "2024-03-26T18:15:10.893",
"references": [
{
"source": "cna@vuldb.com",
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?ctiid.257938"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?id.257938"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?submit.300358"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://vuldb.com/?ctiid.257938"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://vuldb.com/?id.257938"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://vuldb.com/?submit.300358"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"source": "cna@vuldb.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Ha sido declarada cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n formWifiWpsOOB del archivo /goform/WifiWpsOOB. La manipulaci\u00f3n del \u00edndice de argumentos conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257938 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"id": "CVE-2024-2895",
"lastModified": "2026-06-17T07:25:46.413",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-2895",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-05T19:51:36.570635Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-03-26T18:15:10.893",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
},
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.257938"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.257938"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.300358"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.257938"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.257938"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.300358"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T22:09:28+00:00",
"cve": "CVE-2024-2895",
"id": "CVE-2024-2895",
"initial_release_date": "2024-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-2895.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:42.160Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257938 | Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257938"
},
{
"name": "VDB-257938 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257938"
},
{
"name": "Submit #300358 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.300358"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2895",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-05T19:51:36.570635Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T19:52:08.563Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC7 15.03.06.44 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formWifiWpsOOB der Datei /goform/WifiWpsOOB. Durch Beeinflussen des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-26T17:31:04.304Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257938 | Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257938"
},
{
"name": "VDB-257938 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257938"
},
{
"name": "Submit #300358 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.300358"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-26T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-26T10:30:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2895",
"datePublished": "2024-03-26T17:31:04.304Z",
"dateReserved": "2024-03-26T09:25:44.223Z",
"dateUpdated": "2024-08-01T19:25:42.160Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…