cve-2024-2486
Vulnerability from cvelistv5
Published
2024-03-15 08:00
Modified
2024-08-01 19:11
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.
References
Impacted products
Vendor Product Version
Tenda AC18 Version: 15.03.05.05
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-2486",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-03-15T19:13:56.363699Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-07-05T17:22:19.417Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T19:11:53.562Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  name: "VDB-256893 | Tenda AC18 QuickIndex formQuickIndex stack-based overflow",
                  tags: [
                     "vdb-entry",
                     "technical-description",
                     "x_transferred",
                  ],
                  url: "https://vuldb.com/?id.256893",
               },
               {
                  name: "VDB-256893 | CTI Indicators (IOB, IOC, IOA)",
                  tags: [
                     "signature",
                     "permissions-required",
                     "x_transferred",
                  ],
                  url: "https://vuldb.com/?ctiid.256893",
               },
               {
                  tags: [
                     "exploit",
                     "x_transferred",
                  ],
                  url: "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "AC18",
               vendor: "Tenda",
               versions: [
                  {
                     status: "affected",
                     version: "15.03.05.05",
                  },
               ],
            },
         ],
         credits: [
            {
               lang: "en",
               type: "reporter",
               value: "yhryhryhr (VulDB User)",
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.",
            },
            {
               lang: "de",
               value: "Es wurde eine Schwachstelle in Tenda AC18 15.03.05.05 ausgemacht. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formQuickIndex der Datei /goform/QuickIndex. Durch Beeinflussen des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 8.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV3_0: {
                  baseScore: 8.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            },
            {
               cvssV2_0: {
                  baseScore: 9,
                  vectorString: "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                  version: "2.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-121",
                     description: "CWE-121 Stack-based Buffer Overflow",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-03-15T08:00:06.524Z",
            orgId: "1af790b2-7ee1-4545-860a-a788eba489b5",
            shortName: "VulDB",
         },
         references: [
            {
               name: "VDB-256893 | Tenda AC18 QuickIndex formQuickIndex stack-based overflow",
               tags: [
                  "vdb-entry",
                  "technical-description",
               ],
               url: "https://vuldb.com/?id.256893",
            },
            {
               name: "VDB-256893 | CTI Indicators (IOB, IOC, IOA)",
               tags: [
                  "signature",
                  "permissions-required",
               ],
               url: "https://vuldb.com/?ctiid.256893",
            },
            {
               tags: [
                  "exploit",
               ],
               url: "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md",
            },
         ],
         timeline: [
            {
               lang: "en",
               time: "2024-03-15T00:00:00.000Z",
               value: "Advisory disclosed",
            },
            {
               lang: "en",
               time: "2024-03-15T01:00:00.000Z",
               value: "VulDB entry created",
            },
            {
               lang: "en",
               time: "2024-03-15T01:47:36.000Z",
               value: "VulDB entry last update",
            },
         ],
         title: "Tenda AC18 QuickIndex formQuickIndex stack-based overflow",
      },
   },
   cveMetadata: {
      assignerOrgId: "1af790b2-7ee1-4545-860a-a788eba489b5",
      assignerShortName: "VulDB",
      cveId: "CVE-2024-2486",
      datePublished: "2024-03-15T08:00:06.524Z",
      dateReserved: "2024-03-15T00:42:32.950Z",
      dateUpdated: "2024-08-01T19:11:53.562Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      nvd: "{\"cve\":{\"id\":\"CVE-2024-2486\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2024-03-15T08:15:07.160\",\"lastModified\":\"2025-01-14T15:00:51.100\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.\"},{\"lang\":\"es\",\"value\":\"Se encontró una vulnerabilidad en Tenda AC18 15.03.05.05. Ha sido clasificada como crítica. Esto afecta a la función formQuickIndex del archivo /goform/QuickIndex. La manipulación del argumento PPPOEPassword provoca un desbordamiento de búfer en la región stack de la memoria. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al público y puede utilizarse. A esta vulnerabilidad se le asignó el identificador VDB-256893.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D5CB727-FC6B-4212-A61E-2888A0DADFB0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF9F8AF9-F921-4348-922B-EE5E6037E7AC\"}]}]}],\"references\":[{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\",\"Vendor Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.256893\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.256893\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\",\"Vendor Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.256893\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.256893\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}",
      vulnrichment: {
         containers: "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vuldb.com/?id.256893\", \"name\": \"VDB-256893 | Tenda AC18 QuickIndex formQuickIndex stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?ctiid.256893\", \"name\": \"VDB-256893 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\", \"x_transferred\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md\", \"tags\": [\"exploit\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T19:11:53.562Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-2486\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-03-15T19:13:56.363699Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-05T15:20:41.958Z\"}}], \"cna\": {\"title\": \"Tenda AC18 QuickIndex formQuickIndex stack-based overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"yhryhryhr (VulDB User)\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\"}}], \"affected\": [{\"vendor\": \"Tenda\", \"product\": \"AC18\", \"versions\": [{\"status\": \"affected\", \"version\": \"15.03.05.05\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-03-15T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2024-03-15T01:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2024-03-15T01:47:36.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.256893\", \"name\": \"VDB-256893 | Tenda AC18 QuickIndex formQuickIndex stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.256893\", \"name\": \"VDB-256893 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md\", \"tags\": [\"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.\"}, {\"lang\": \"de\", \"value\": \"Es wurde eine Schwachstelle in Tenda AC18 15.03.05.05 ausgemacht. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formQuickIndex der Datei /goform/QuickIndex. Durch Beeinflussen des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \\u00fcber das Netzwerk erfolgen. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2024-03-15T08:00:06.524Z\"}}}",
         cveMetadata: "{\"cveId\": \"CVE-2024-2486\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T19:11:53.562Z\", \"dateReserved\": \"2024-03-15T00:42:32.950Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2024-03-15T08:00:06.524Z\", \"assignerShortName\": \"VulDB\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.