cve-2024-23141
Vulnerability from cvelistv5
Published
2024-06-25 01:22
Modified
2024-08-01 22:59
Severity ?
EPSS score ?
Summary
A maliciously crafted MODEL file, when parsed in libodxdll through Autodesk applications, can cause a double free. This vulnerability, along with other vulnerabilities, can lead to code execution in the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Autodesk | Autodesk applications |
Version: 2024 |
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:autodesk:autocad:2024:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "autocad", "vendor": "autodesk", "versions": [ { "status": "affected", "version": "2024" } ] }, { "cpes": [ "cpe:2.3:a:autodesk:advance_steel:2024:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "advance_steel", "vendor": "autodesk", "versions": [ { "status": "affected", "version": "2024" } ] }, { "cpes": [ "cpe:2.3:a:autodesk:civil_3d:2024:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "civil_3d", "vendor": "autodesk", "versions": [ { "status": "affected", "version": "2024" } ] }, { "cpes": [ "cpe:2.3:a:autodesk:autocad_architecture:2024:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "autocad_architecture", "vendor": "autodesk", "versions": [ { "status": "affected", "version": "2024" } ] }, { "cpes": [ "cpe:2.3:a:autodesk:autocad_electrical:2024:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "autocad_electrical", "vendor": "autodesk", "versions": [ { "status": "affected", "version": "2024" } ] }, { "cpes": [ "cpe:2.3:a:autodesk:autocad_map_3d:2024:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "autocad_map_3d", "vendor": "autodesk", "versions": [ { "status": "affected", "version": "2024" } ] }, { "cpes": [ "cpe:2.3:a:autodesk:autocad_mechanical:2024:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "autocad_mechanical", "vendor": "autodesk", "versions": [ { "status": "affected", "version": "2024" } ] }, { "cpes": [ "cpe:2.3:a:autodesk:autocad_mep:2024:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "autocad_mep", "vendor": "autodesk", "versions": [ { "status": "affected", "version": "2024" } ] }, { "cpes": [ "cpe:2.3:a:autodesk:autocad_plant_3d:2024:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "autocad_plant_3d", "vendor": "autodesk", "versions": [ { "status": "affected", "version": "2024" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-23141", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-25T13:49:27.556946Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-25T13:49:33.135Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T22:59:31.764Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0009" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autodesk applications", "vendor": "Autodesk", "versions": [ { "status": "affected", "version": "2024" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA maliciously crafted MODEL file, when parsed in libodxdll through Autodesk applications, can cause a double free. This vulnerability, along with other vulnerabilities, can lead to code execution in the current process.\u003c/span\u003e\u003cbr\u003e" } ], "value": "A maliciously crafted MODEL file, when parsed in libodxdll through Autodesk applications, can cause a double free. This vulnerability, along with other vulnerabilities, can lead to code execution in the current process." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-415", "description": "CWE-415 Double Free", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-25T01:22:38.407Z", "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601", "shortName": "autodesk" }, "references": [ { "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0009" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601", "assignerShortName": "autodesk", "cveId": "CVE-2024-23141", "datePublished": "2024-06-25T01:22:38.407Z", "dateReserved": "2024-01-11T21:51:08.013Z", "dateUpdated": "2024-08-01T22:59:31.764Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-23141\",\"sourceIdentifier\":\"psirt@autodesk.com\",\"published\":\"2024-06-25T02:15:11.030\",\"lastModified\":\"2024-11-21T08:57:02.740\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A maliciously crafted MODEL file, when parsed in libodxdll through Autodesk applications, can cause a double free. This vulnerability, along with other vulnerabilities, can lead to code execution in the current process.\"},{\"lang\":\"es\",\"value\":\"Un archivo MODEL creado con fines malintencionados, cuando se analiza en libodxdll a trav\u00e9s de aplicaciones de Autodesk, puede provocar una doble liberaci\u00f3n. Esta vulnerabilidad, junto con otras vulnerabilidades, puede provocar la ejecuci\u00f3n de c\u00f3digo en el proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt@autodesk.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-415\"}]}],\"references\":[{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0009\",\"source\":\"psirt@autodesk.com\"},{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0009\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.