cve-2024-20482
Vulnerability from cvelistv5
Published
2024-10-23 17:52
Modified
2024-10-26 03:55
Summary
A vulnerability in the web-based management interface of Cisco Secure Firewall Management Center (FMC) Software, formerly Firepower Management Center Software, could allow an authenticated, remote attacker to elevate privileges on an affected device. To exploit this vulnerability, an attacker must have a valid account on the device that is configured with a custom read-only role. This vulnerability is due to insufficient validation of role permissions in part of the web-based management interface. An attacker could exploit this vulnerability by performing a write operation on the affected part of the web-based management interface. A successful exploit could allow the attacker to modify certain parts of the configuration.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-20482",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-25T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-26T03:55:29.925Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Firepower Management Center",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "7.2.0"
            },
            {
              "status": "affected",
              "version": "7.2.1"
            },
            {
              "status": "affected",
              "version": "7.2.2"
            },
            {
              "status": "affected",
              "version": "7.2.0.1"
            },
            {
              "status": "affected",
              "version": "7.2.3"
            },
            {
              "status": "affected",
              "version": "7.2.3.1"
            },
            {
              "status": "affected",
              "version": "7.2.4"
            },
            {
              "status": "affected",
              "version": "7.2.4.1"
            },
            {
              "status": "affected",
              "version": "7.2.5"
            },
            {
              "status": "affected",
              "version": "7.2.5.1"
            },
            {
              "status": "affected",
              "version": "7.2.6"
            },
            {
              "status": "affected",
              "version": "7.2.7"
            },
            {
              "status": "affected",
              "version": "7.2.5.2"
            },
            {
              "status": "affected",
              "version": "7.2.8"
            },
            {
              "status": "affected",
              "version": "7.2.8.1"
            },
            {
              "status": "affected",
              "version": "7.3.0"
            },
            {
              "status": "affected",
              "version": "7.3.1"
            },
            {
              "status": "affected",
              "version": "7.3.1.1"
            },
            {
              "status": "affected",
              "version": "7.3.1.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based management interface of Cisco Secure Firewall Management Center (FMC) Software, formerly Firepower Management Center Software, could allow an authenticated, remote attacker to elevate privileges on an affected device. To exploit this vulnerability, an attacker must have a valid account on the device that is configured with a custom read-only role.\r\n\r This vulnerability is due to insufficient validation of role permissions in part of the web-based management interface. An attacker could exploit this vulnerability by performing a write operation on the affected part of the web-based management interface. A successful exploit could allow the attacker to modify certain parts of the configuration."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "cvssV3_1"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "Incorrect Authorization",
              "lang": "en",
              "type": "cwe"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T17:52:08.555Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "cisco-sa-fmc-priv-esc-CMQ4S6m7",
          "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-priv-esc-CMQ4S6m7"
        }
      ],
      "source": {
        "advisory": "cisco-sa-fmc-priv-esc-CMQ4S6m7",
        "defects": [
          "CSCwj41973"
        ],
        "discovery": "INTERNAL"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2024-20482",
    "datePublished": "2024-10-23T17:52:08.555Z",
    "dateReserved": "2023-11-08T15:08:07.684Z",
    "dateUpdated": "2024-10-26T03:55:29.925Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-20482\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2024-10-23T18:15:12.063\",\"lastModified\":\"2024-11-01T19:49:21.493\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of Cisco Secure Firewall Management Center (FMC) Software, formerly Firepower Management Center Software, could allow an authenticated, remote attacker to elevate privileges on an affected device. To exploit this vulnerability, an attacker must have a valid account on the device that is configured with a custom read-only role.\\r\\n\\r This vulnerability is due to insufficient validation of role permissions in part of the web-based management interface. An attacker could exploit this vulnerability by performing a write operation on the affected part of the web-based management interface. A successful exploit could allow the attacker to modify certain parts of the configuration.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de administraci\u00f3n basada en web del software Cisco Secure Firewall Management Center (FMC), anteriormente Firepower Management Center Software, podr\u00eda permitir que un atacante remoto autenticado eleve los privilegios en un dispositivo afectado. Para aprovechar esta vulnerabilidad, un atacante debe tener una cuenta v\u00e1lida en el dispositivo que est\u00e9 configurada con un rol de solo lectura personalizado. Esta vulnerabilidad se debe a una validaci\u00f3n insuficiente de los permisos de rol en parte de la interfaz de administraci\u00f3n basada en web. Un atacante podr\u00eda aprovechar esta vulnerabilidad al realizar una operaci\u00f3n de escritura en la parte afectada de la interfaz de administraci\u00f3n basada en web. Una explotaci\u00f3n exitosa podr\u00eda permitir al atacante modificar ciertas partes de la configuraci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FB5ACB9E-86AF-4EC1-9F36-A202429CD0F4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.0.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AD1E4527-AAE2-4DA9-AFDA-6375839F7843\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2F0AF047-EAE9-4C77-BCEF-5CB26F84C742\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2ED03874-4071-4382-8A46-8B3A59E601FF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF84E043-DF3C-4A95-8FDA-B0FDCD795377\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B9498087-9642-4A86-B3EE-1513C55A86E2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"36C229AB-2851-48D4-815A-63AAB4462A24\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.4.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DA4BCFC-8237-4F5C-9863-523EE7D8619B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07693A92-7D84-45A1-ACD6-D83AE41D504B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.5.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2C78050A-A5FB-427B-BF0D-0353B240A4FF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.5.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85E76AE7-12AC-4419-AE66-43730B173B4E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D803EC9-26EE-4799-A435-C782C92739CF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.7:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6EEF87CD-2335-4886-A65C-4E33775AEC52\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.8:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"953EB81A-1B53-4A57-9F59-D4A7D37E657E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.2.8.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1CB534BC-3E4D-4484-AFD0-69524B1F07F9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5D401072-6709-4921-8918-720F28D61E24\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C0EA3467-4205-4C41-AF24-689330F7396B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.3.1.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9BE94E38-5F29-4AE1-8129-7F7582C2CC75\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:7.3.1.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FEF603AD-D69B-4DD8-A7F4-6BEFD355EF29\"}]}]}],\"references\":[{\"url\":\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-priv-esc-CMQ4S6m7\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.