CVE-2023-39167 (GCVE-0-2023-39167)
Vulnerability from cvelistv5
Published
2023-12-07 14:05
Modified
2025-11-04 19:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-862 - Missing Authorization
Summary
In SENEC Storage Box V1,V2 and V3 an unauthenticated remote attacker can obtain the devices' logfiles that contain sensitive data.
References
| URL | Tags | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SENEC | Storage Box V1 |
Version: all (until 19.06.2023) |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:17:34.708Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2023/Nov/5"
},
{
"url": "http://seclists.org/fulldisclosure/2023/Nov/10"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Storage Box V1",
"vendor": "SENEC",
"versions": [
{
"status": "affected",
"version": "all (until 19.06.2023)"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Storage Box V2",
"vendor": "SENEC",
"versions": [
{
"status": "affected",
"version": "all (until 19.06.2023)"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Storage Box V3",
"vendor": "SENEC",
"versions": [
{
"status": "affected",
"version": "all (until 19.06.2023)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Ph0s[4]"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "R0ckE7"
}
],
"datePublic": "2023-12-07T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In\u0026nbsp;SENEC Storage Box V1,V2 and V3 an unauthenticated remote attacker can obtain the devices\u0027 logfiles that contain sensitive data."
}
],
"value": "In\u00a0SENEC Storage Box V1,V2 and V3 an unauthenticated remote attacker can obtain the devices\u0027 logfiles that contain sensitive data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862 Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T14:35:53.018Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://seclists.org/fulldisclosure/2023/Nov/5"
}
],
"source": {
"defect": [
"CERT@VDE#64567"
],
"discovery": "EXTERNAL"
},
"title": "SENEC: Storage Box V1,V2 and V3 affected by improper access control vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-39167",
"datePublished": "2023-12-07T14:05:01.746Z",
"dateReserved": "2023-07-25T14:06:01.343Z",
"dateUpdated": "2025-11-04T19:17:34.708Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2023-39167\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2023-12-07T14:15:07.467\",\"lastModified\":\"2025-11-04T20:16:35.447\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In\u00a0SENEC Storage Box V1,V2 and V3 an unauthenticated remote attacker can obtain the devices\u0027 logfiles that contain sensitive data.\"},{\"lang\":\"es\",\"value\":\"En SENEC Storage Box V1, V2 y V3, un atacante remoto no autenticado puede obtener los archivos de registro de los dispositivos que contienen datos confidenciales.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-862\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-862\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:enbw:senec_storage_box_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2023-06-19\",\"matchCriteriaId\":\"8C6796ED-84F3-47E8-BD21-5CEBC1DD62E0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:enbw:senec_storage_box:v1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1A73E447-D78F-420B-B256-1F157A6DA364\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:enbw:senec_storage_box_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2023-06-19\",\"matchCriteriaId\":\"8C6796ED-84F3-47E8-BD21-5CEBC1DD62E0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:enbw:senec_storage_box:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"300B219B-45CA-44C0-AC39-D94057FA8860\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:enbw:senec_storage_box_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2023-06-19\",\"matchCriteriaId\":\"8C6796ED-84F3-47E8-BD21-5CEBC1DD62E0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:enbw:senec_storage_box:v3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"449C542C-CAE3-42A9-BF45-EE6E828A4EBE\"}]}]}],\"references\":[{\"url\":\"https://seclists.org/fulldisclosure/2023/Nov/5\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Exploit\",\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"http://seclists.org/fulldisclosure/2023/Nov/10\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://seclists.org/fulldisclosure/2023/Nov/5\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Mailing List\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…