cve-2023-1145
Vulnerability from cvelistv5
Published
2023-03-27 14:56
Modified
2024-08-02 05:32
Severity ?
EPSS score ?
Summary
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Delta Electronics | InfraSuite Device Master |
Version: 0 < 1.0.5 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:32:46.465Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "InfraSuite Device Master", "vendor": "Delta Electronics", "versions": [ { "lessThan": "1.0.5", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Piotr Bazydlo (@chudypd) of Trend Micro and Anonymous working with Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA." } ], "datePublic": "2023-03-21T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e" } ], "value": "\n\n\n\n\n\n\nDelta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.\n\n\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-27T14:57:19.579Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users uninstall old versions of InfraSuite Device Master and reinstall the updated version 1.0.5 \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.5(x64).exe\"\u003eusing the installer\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\n\n\u003cbr\u003e" } ], "value": "\n\n\nDelta Electronics recommends users uninstall old versions of InfraSuite Device Master and reinstall the updated version 1.0.5 using the installer https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.5(x64).exe .\n\n\n\n\n" } ], "source": { "advisory": "ICSA-23-080-02", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-1145", "datePublished": "2023-03-27T14:56:30.287Z", "dateReserved": "2023-03-01T23:26:44.830Z", "dateUpdated": "2024-08-02T05:32:46.465Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-1145\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2023-03-27T15:15:08.277\",\"lastModified\":\"2024-11-21T07:38:32.750\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\n\\n\\n\\n\\n\\n\\nDelta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.\\n\\n\\n\\n\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-502\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-502\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.5\",\"matchCriteriaId\":\"CCCA3760-38A4-4DBF-98D3-1A6799317836\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.