CVE-2022-43958 (GCVE-0-2022-43958)
Vulnerability from cvelistv5
- CWE-256 - Plaintext Storage of a Password
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | QMS Automotive |
Version: All versions < V12.39 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:47:04.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43958",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:22:05.948524Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:46:20.800Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "QMS Automotive",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V12.39"
}
]
},
{
"defaultStatus": "unknown",
"product": "QMS Automotive",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V12.39"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39), QMS Automotive (All versions \u003c V12.39). User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256: Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:32:02.019Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43958",
"datePublished": "2022-11-08T00:00:00.000Z",
"dateReserved": "2022-10-27T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:46:20.800Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-43958\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-11-08T11:15:12.193\",\"lastModified\":\"2024-11-21T07:27:24.770\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39), QMS Automotive (All versions \u003c V12.39). User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en QMS Automotive (todas las versiones \u0026lt; V12.39), QMS Automotive (todas las versiones \u0026lt; V12.39). Las credenciales de usuario se almacenan en texto plano en la base de datos sin ning\u00fan mecanismo de hash. Esto podr\u00eda permitir a un atacante obtener acceso a las credenciales y suplantar a otros usuarios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L\",\"baseScore\":7.6,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.1,\"impactScore\":5.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-256\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:qms_automotive:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"495D38E5-5C7F-43C2-997F-D2226C7D0A2C\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T13:47:04.389Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-43958\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-18T15:22:05.948524Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-18T15:22:09.273Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.6, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"QMS Automotive\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V12.39\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"QMS Automotive\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V12.39\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39), QMS Automotive (All versions \u003c V12.39). User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-256\", \"description\": \"CWE-256: Plaintext Storage of a Password\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-09-12T09:32:02.019Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-43958\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-21T13:46:20.800Z\", \"dateReserved\": \"2022-10-27T00:00:00.000Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2022-11-08T00:00:00.000Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
gsd-2022-43958
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2022-43958",
"id": "GSD-2022-43958"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-43958"
],
"details": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39), QMS Automotive (All versions \u003c V12.39). User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.",
"id": "GSD-2022-43958",
"modified": "2023-12-13T01:19:32.323842Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-43958",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QMS Automotive",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V12.39"
},
{
"version_affected": "=",
"version_value": "All versions \u003c V12.39"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39), QMS Automotive (All versions \u003c V12.39). User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-256",
"lang": "eng",
"value": "CWE-256: Plaintext Storage of a Password"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:qms_automotive:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-43958"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39), QMS Automotive (All versions \u003c V12.39). User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-256"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf",
"refsource": "MISC",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf",
"refsource": "MISC",
"tags": [],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 5.5
}
},
"lastModifiedDate": "2023-09-12T10:15Z",
"publishedDate": "2022-11-08T11:15Z"
}
}
}
ICSA-22-314-06
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "QMS Automotive contains a vulnerability that stores user credentials in plantext within the user database. This could allow an attacker to read credentials from memory. \n\nSiemens has released an update for QMS Automotive and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-587547: Unencrypted Storage of User Credentials in QMS Automotive - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-587547.json"
},
{
"category": "self",
"summary": "SSA-587547: Unencrypted Storage of User Credentials in QMS Automotive - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-587547.html"
},
{
"category": "self",
"summary": "SSA-587547: Unencrypted Storage of User Credentials in QMS Automotive - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf"
},
{
"category": "self",
"summary": "SSA-587547: Unencrypted Storage of User Credentials in QMS Automotive - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-587547.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-314-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-314-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-314-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens QMS Automotive",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-314-06",
"initial_release_date": "2022-11-08T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-11-08T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-09-12T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for QMS Automotive and updated CWE information of CVE-2022-43958"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "3",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.39",
"product": {
"name": "QMS Automotive",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "QMS Automotive"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-43958",
"cwe": {
"id": "CWE-256",
"name": "Plaintext Storage of a Password"
},
"notes": [
{
"category": "summary",
"text": "User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Enable encryption for user passwords. See user manual under \u2018Administration\u2019 for further details",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-43958"
}
]
}
icsa-23-257-03
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "QMS Automotive before V12.39 contains multiple vulnerabilities that could allow an attacker to perform malicious code injection, information disclosure or lead to a denial of service condition. \n\nSiemens has released an update for QMS Automotive and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-147266.json"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-147266.html"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-147266.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-257-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-257-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-257-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-257-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemans QMS Automotive",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-257-03",
"initial_release_date": "2023-09-12T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-09-12T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.39",
"product": {
"name": "QMS Automotive",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "QMS Automotive"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-43958",
"cwe": {
"id": "CWE-256",
"name": "Plaintext Storage of a Password"
},
"notes": [
{
"category": "summary",
"text": "User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-43958"
},
{
"cve": "CVE-2023-40724",
"cwe": {
"id": "CWE-316",
"name": "Cleartext Storage of Sensitive Information in Memory"
},
"notes": [
{
"category": "summary",
"text": "User credentials are found in memory as plaintext. An attacker could perform a memory dump, and get access to credentials, and use it for impersonation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40724"
},
{
"cve": "CVE-2023-40725",
"cwe": {
"id": "CWE-209",
"name": "Generation of Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application returns inconsistent error messages in response to invalid user credentials during login session. This allows an attacker to enumerate usernames, and identify valid usernames.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.0,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40725"
},
{
"cve": "CVE-2023-40726",
"cwe": {
"id": "CWE-550",
"name": "Server-generated Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application server responds with sensitive information about the server. This could allow an attacker to directly access the database.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40726"
},
{
"cve": "CVE-2023-40727",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application uses weak outdated application signing mechanism. This could allow an attacker to tamper the application code.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40727"
},
{
"cve": "CVE-2023-40728",
"cwe": {
"id": "CWE-922",
"name": "Insecure Storage of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application stores sensitive application data in an external insecure storage. This could allow an attacker to alter content, leading to arbitrary code execution or denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40728"
},
{
"cve": "CVE-2023-40729",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application lacks security control to prevent unencrypted communication without HTTPS. An attacker who managed to gain machine-in-the-middle position could manipulate, or steal confidential information.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40729"
},
{
"cve": "CVE-2023-40730",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application lacks sufficient authorization checks. This could allow an attacker to access confidential information, perform administrative functions, or lead to a denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40730"
},
{
"cve": "CVE-2023-40731",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "summary",
"text": "The affected application allows users to upload arbitrary file types. This could allow an attacker to upload malicious files, that could potentially lead to code tampering.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40731"
},
{
"cve": "CVE-2023-40732",
"cwe": {
"id": "CWE-613",
"name": "Insufficient Session Expiration"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40732"
}
]
}
icsa-22-314-06
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "QMS Automotive contains a vulnerability that stores user credentials in plantext within the user database. This could allow an attacker to read credentials from memory. \n\nSiemens has released an update for QMS Automotive and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-587547: Unencrypted Storage of User Credentials in QMS Automotive - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-587547.json"
},
{
"category": "self",
"summary": "SSA-587547: Unencrypted Storage of User Credentials in QMS Automotive - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-587547.html"
},
{
"category": "self",
"summary": "SSA-587547: Unencrypted Storage of User Credentials in QMS Automotive - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf"
},
{
"category": "self",
"summary": "SSA-587547: Unencrypted Storage of User Credentials in QMS Automotive - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-587547.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-314-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-314-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-314-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens QMS Automotive",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-314-06",
"initial_release_date": "2022-11-08T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-11-08T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-09-12T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for QMS Automotive and updated CWE information of CVE-2022-43958"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "3",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.39",
"product": {
"name": "QMS Automotive",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "QMS Automotive"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-43958",
"cwe": {
"id": "CWE-256",
"name": "Plaintext Storage of a Password"
},
"notes": [
{
"category": "summary",
"text": "User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Enable encryption for user passwords. See user manual under \u2018Administration\u2019 for further details",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-43958"
}
]
}
ICSA-23-257-03
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "QMS Automotive before V12.39 contains multiple vulnerabilities that could allow an attacker to perform malicious code injection, information disclosure or lead to a denial of service condition. \n\nSiemens has released an update for QMS Automotive and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-147266.json"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-147266.html"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-147266.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-257-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-257-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-257-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-257-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemans QMS Automotive",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-257-03",
"initial_release_date": "2023-09-12T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-09-12T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.39",
"product": {
"name": "QMS Automotive",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "QMS Automotive"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-43958",
"cwe": {
"id": "CWE-256",
"name": "Plaintext Storage of a Password"
},
"notes": [
{
"category": "summary",
"text": "User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-43958"
},
{
"cve": "CVE-2023-40724",
"cwe": {
"id": "CWE-316",
"name": "Cleartext Storage of Sensitive Information in Memory"
},
"notes": [
{
"category": "summary",
"text": "User credentials are found in memory as plaintext. An attacker could perform a memory dump, and get access to credentials, and use it for impersonation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40724"
},
{
"cve": "CVE-2023-40725",
"cwe": {
"id": "CWE-209",
"name": "Generation of Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application returns inconsistent error messages in response to invalid user credentials during login session. This allows an attacker to enumerate usernames, and identify valid usernames.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.0,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40725"
},
{
"cve": "CVE-2023-40726",
"cwe": {
"id": "CWE-550",
"name": "Server-generated Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application server responds with sensitive information about the server. This could allow an attacker to directly access the database.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40726"
},
{
"cve": "CVE-2023-40727",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application uses weak outdated application signing mechanism. This could allow an attacker to tamper the application code.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40727"
},
{
"cve": "CVE-2023-40728",
"cwe": {
"id": "CWE-922",
"name": "Insecure Storage of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application stores sensitive application data in an external insecure storage. This could allow an attacker to alter content, leading to arbitrary code execution or denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40728"
},
{
"cve": "CVE-2023-40729",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application lacks security control to prevent unencrypted communication without HTTPS. An attacker who managed to gain machine-in-the-middle position could manipulate, or steal confidential information.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40729"
},
{
"cve": "CVE-2023-40730",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application lacks sufficient authorization checks. This could allow an attacker to access confidential information, perform administrative functions, or lead to a denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40730"
},
{
"cve": "CVE-2023-40731",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "summary",
"text": "The affected application allows users to upload arbitrary file types. This could allow an attacker to upload malicious files, that could potentially lead to code tampering.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40731"
},
{
"cve": "CVE-2023-40732",
"cwe": {
"id": "CWE-613",
"name": "Insufficient Session Expiration"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40732"
}
]
}
CERTFR-2022-AVI-1001
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions antérieures à V2.50 | ||
| Siemens | N/A | SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SINUMERIK MC toutes versions | ||
| Siemens | N/A | SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0) toutes versions | ||
| Siemens | N/A | SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SINUMERIK ONE toutes versions | ||
| Siemens | N/A | SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | Parasolid versions antérieures à V34.0.254 | ||
| Siemens | N/A | SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions antérieures à V2.50 | ||
| Siemens | N/A | Teamcenter Visualization V14.0 versions antérieures à V14.0.0.3 | ||
| Siemens | N/A | SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0) versions antérieures à V3.3.19 | ||
| Siemens | N/A | Teamcenter Visualization V14.1 versions antérieures à V14.1.0.4 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0) toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC Drive Controller family toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | Teamcenter Visualization V13.3 versions antérieures à V13.3.0.7 | ||
| Siemens | N/A | Parasolid versions antérieures à V35.0.184 | ||
| Siemens | N/A | JT2Go versions antérieures à V14.1.0.4 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-PLCSIM Advanced toutes versions | ||
| Siemens | N/A | QMS Automotive toutes versions | ||
| Siemens | N/A | SIMATIC PC Station versions antérieures à V2.1 | ||
| Siemens | N/A | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | Parasolid versions antérieures à V34.1.244 | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0) versions antérieures à V3.3.19 | ||
| Siemens | N/A | RUGGEDCOM ROS toutes versions | ||
| Siemens | N/A | SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0) toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller toutes versions | ||
| Siemens | N/A | SINEC NMS versions antérieures à 1.0.3 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0) versions antérieures à V3.2.19 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions ant\u00e9rieures \u00e0 V2.50",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK MC toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK ONE toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions ant\u00e9rieures \u00e0 V34.0.254",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions ant\u00e9rieures \u00e0 V2.50",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization V14.0 versions ant\u00e9rieures \u00e0 V14.0.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0) versions ant\u00e9rieures \u00e0 V3.3.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization V14.1 versions ant\u00e9rieures \u00e0 V14.1.0.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Drive Controller family toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization V13.3 versions ant\u00e9rieures \u00e0 V13.3.0.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions ant\u00e9rieures \u00e0 V35.0.184",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 V14.1.0.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PLCSIM Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "QMS Automotive toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PC Station versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions ant\u00e9rieures \u00e0 V34.1.244",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0) versions ant\u00e9rieures \u00e0 V3.3.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC NMS versions ant\u00e9rieures \u00e0 1.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-37889",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37889"
},
{
"name": "CVE-2022-39157",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39157"
},
{
"name": "CVE-2022-41664",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41664"
},
{
"name": "CVE-2022-41662",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41662"
},
{
"name": "CVE-2022-37891",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37891"
},
{
"name": "CVE-2022-41663",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41663"
},
{
"name": "CVE-2022-37888",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37888"
},
{
"name": "CVE-2002-20001",
"url": "https://www.cve.org/CVERecord?id=CVE-2002-20001"
},
{
"name": "CVE-2022-43397",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43397"
},
{
"name": "CVE-2022-43545",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43545"
},
{
"name": "CVE-2022-37893",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37893"
},
{
"name": "CVE-2022-37892",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37892"
},
{
"name": "CVE-2022-39158",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39158"
},
{
"name": "CVE-2022-37890",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37890"
},
{
"name": "CVE-2022-43958",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43958"
},
{
"name": "CVE-2022-37895",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37895"
},
{
"name": "CVE-2022-37896",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37896"
},
{
"name": "CVE-2022-41661",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41661"
},
{
"name": "CVE-2022-43398",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43398"
},
{
"name": "CVE-2022-39136",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39136"
},
{
"name": "CVE-2022-30694",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30694"
},
{
"name": "CVE-2021-42550",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42550"
},
{
"name": "CVE-2022-37886",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37886"
},
{
"name": "CVE-2022-38465",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-38465"
},
{
"name": "CVE-2022-37885",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37885"
},
{
"name": "CVE-2022-37887",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37887"
},
{
"name": "CVE-2022-37894",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37894"
},
{
"name": "CVE-2022-43439",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43439"
},
{
"name": "CVE-2022-41660",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41660"
},
{
"name": "CVE-2022-43546",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43546"
}
],
"initial_release_date": "2022-11-08T00:00:00",
"last_revision_date": "2022-11-08T00:00:00",
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 478960 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-478960.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 568428 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-568428.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 853037 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-853037.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 120378 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-120378.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 587547 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-587547.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 506569 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-506569.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 570294 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-570294.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 787941 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-787941.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 371761 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-371761.html"
}
],
"reference": "CERTFR-2022-AVI-1001",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-11-08T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 853037 du 08 novembre 2022",
"url": null
}
]
}
CERTFR-2023-AVI-0733
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMIT Simulation Platform toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Teamcenter Visualization versions 14.1.x antérieures à 14.1.0.11 | ||
| Siemens | N/A | PSS(R)ODMS V13.0 toutes versions | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller V2 versions antérieures à 21.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Parasolid versions 36.0.x antérieures à 36.0.142 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Teamcenter Visualization versions 14.2.x antérieures à 14.2.0.6 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Parasolid versions 35.0.x antérieures à 35.0.253 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Parasolid versions 34.1.x antérieures à 34.1.258 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | PSS(R)CAPE versions 14.x antérieures à 14.2023-08-23 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | PSS(R)ODMS versions 13.1.x antérieures à 13.1.12.1 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Teamcenter Visualization versions 14.3.x antérieures à 14.3.0.1 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) versions antérieures à 2.2 | ||
| Siemens | N/A | Teamcenter Visualization versions 13.3.x antérieures à 13.3.0.12 | ||
| Siemens | N/A | RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | PSS(R)E versions 34.x antérieures à 34.9.6 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) versions antérieures à 2.2 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC WinCC OA versions 3.19.x antérieures à 3.19 P006 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | PSS(R)CAPE versions 15.x antérieures à 15.0.22 | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) versions antérieures à 21.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Parasolid versions 35.1.x antérieures à 35.1.184 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | PSS(R)E V35 toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | JT2Go versions antérieures à 14.3.0.1 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | QMS Automotive versions antérieures à 12.39 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0) versions antérieures à 3.0.3 |
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMIT Simulation Platform toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 14.1.x ant\u00e9rieures \u00e0 14.1.0.11",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)ODMS V13.0 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller V2 versions ant\u00e9rieures \u00e0 21.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions 36.0.x ant\u00e9rieures \u00e0 36.0.142",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 14.2.x ant\u00e9rieures \u00e0 14.2.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions 35.0.x ant\u00e9rieures \u00e0 35.0.253",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions 34.1.x ant\u00e9rieures \u00e0 34.1.258",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)CAPE versions 14.x ant\u00e9rieures \u00e0 14.2023-08-23",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)ODMS versions 13.1.x ant\u00e9rieures \u00e0 13.1.12.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 14.3.x ant\u00e9rieures \u00e0 14.3.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) versions ant\u00e9rieures \u00e0 2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 13.3.x ant\u00e9rieures \u00e0 13.3.0.12",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)E versions 34.x ant\u00e9rieures \u00e0 34.9.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) versions ant\u00e9rieures \u00e0 2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA versions 3.19.x ant\u00e9rieures \u00e0 3.19 P006",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)CAPE versions 15.x ant\u00e9rieures \u00e0 15.0.22",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) versions ant\u00e9rieures \u00e0 21.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions 35.1.x ant\u00e9rieures \u00e0 35.1.184",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)E V35 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 14.3.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "QMS Automotive versions ant\u00e9rieures \u00e0 12.39",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-40728",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40728"
},
{
"name": "CVE-2022-35894",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35894"
},
{
"name": "CVE-2022-32953",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32953"
},
{
"name": "CVE-2023-40724",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40724"
},
{
"name": "CVE-2023-27373",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27373"
},
{
"name": "CVE-2023-3935",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3935"
},
{
"name": "CVE-2023-38072",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38072"
},
{
"name": "CVE-2023-38075",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38075"
},
{
"name": "CVE-2022-30283",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30283"
},
{
"name": "CVE-2023-38073",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38073"
},
{
"name": "CVE-2023-40730",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40730"
},
{
"name": "CVE-2023-24932",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24932"
},
{
"name": "CVE-2023-40732",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40732"
},
{
"name": "CVE-2022-32475",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32475"
},
{
"name": "CVE-2022-29275",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29275"
},
{
"name": "CVE-2022-35893",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35893"
},
{
"name": "CVE-2022-32954",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32954"
},
{
"name": "CVE-2023-40725",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40725"
},
{
"name": "CVE-2021-38578",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-38578"
},
{
"name": "CVE-2022-32469",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32469"
},
{
"name": "CVE-2022-43958",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43958"
},
{
"name": "CVE-2023-41033",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-41033"
},
{
"name": "CVE-2022-27405",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27405"
},
{
"name": "CVE-2022-40982",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40982"
},
{
"name": "CVE-2023-38071",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38071"
},
{
"name": "CVE-2022-35895",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35895"
},
{
"name": "CVE-2023-40726",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40726"
},
{
"name": "CVE-2022-24350",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24350"
},
{
"name": "CVE-2023-38070",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38070"
},
{
"name": "CVE-2022-32470",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32470"
},
{
"name": "CVE-2023-38074",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38074"
},
{
"name": "CVE-2022-35896",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35896"
},
{
"name": "CVE-2022-36338",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36338"
},
{
"name": "CVE-2017-5715",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5715"
},
{
"name": "CVE-2023-28831",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28831"
},
{
"name": "CVE-2022-32477",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32477"
},
{
"name": "CVE-2023-40727",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40727"
},
{
"name": "CVE-2022-32471",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32471"
},
{
"name": "CVE-2023-40731",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40731"
},
{
"name": "CVE-2023-31041",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-31041"
},
{
"name": "CVE-2023-40729",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40729"
},
{
"name": "CVE-2022-30772",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30772"
},
{
"name": "CVE-2023-38076",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38076"
},
{
"name": "CVE-2023-41032",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-41032"
},
{
"name": "CVE-2022-24351",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24351"
}
],
"initial_release_date": "2023-09-12T00:00:00",
"last_revision_date": "2023-09-12T00:00:00",
"links": [],
"reference": "CERTFR-2023-AVI-0733",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-09-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eles produits Siemens\u003c/span\u003e. Certaines d\u0027entre elles\npermettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire\n\u00e0 distance, un d\u00e9ni de service \u00e0 distance et une \u00e9l\u00e9vation de\nprivil\u00e8ges.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-278349 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-981975.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-147266 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-147266.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-240541 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-957369.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-957369 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-240541.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-190839 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-190839.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-981975 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-711309.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-711309 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-278349.html"
}
]
}
ssa-147266
Vulnerability from csaf_siemens
Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "QMS Automotive before V12.39 contains multiple vulnerabilities that could allow an attacker to perform malicious code injection, information disclosure or lead to a denial of service condition. \n\nSiemens has released an update for QMS Automotive and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-147266.html"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-147266.json"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-147266.txt"
}
],
"title": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39",
"tracking": {
"current_release_date": "2023-09-12T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-147266",
"initial_release_date": "2023-09-12T00:00:00Z",
"revision_history": [
{
"date": "2023-09-12T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV12.39",
"product": {
"name": "QMS Automotive",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "QMS Automotive"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-43958",
"cwe": {
"id": "CWE-256",
"name": "Plaintext Storage of a Password"
},
"notes": [
{
"category": "summary",
"text": "User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-43958"
},
{
"cve": "CVE-2023-40724",
"cwe": {
"id": "CWE-316",
"name": "Cleartext Storage of Sensitive Information in Memory"
},
"notes": [
{
"category": "summary",
"text": "User credentials are found in memory as plaintext. An attacker could perform a memory dump, and get access to credentials, and use it for impersonation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-40724"
},
{
"cve": "CVE-2023-40725",
"cwe": {
"id": "CWE-209",
"name": "Generation of Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application returns inconsistent error messages in response to invalid user credentials during login session. This allows an attacker to enumerate usernames, and identify valid usernames.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.0,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-40725"
},
{
"cve": "CVE-2023-40726",
"cwe": {
"id": "CWE-550",
"name": "Server-generated Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application server responds with sensitive information about the server. This could allow an attacker to directly access the database.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-40726"
},
{
"cve": "CVE-2023-40727",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application uses weak outdated application signing mechanism. This could allow an attacker to tamper the application code.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-40727"
},
{
"cve": "CVE-2023-40728",
"cwe": {
"id": "CWE-922",
"name": "Insecure Storage of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application stores sensitive application data in an external insecure storage. This could allow an attacker to alter content, leading to arbitrary code execution or denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-40728"
},
{
"cve": "CVE-2023-40729",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application lacks security control to prevent unencrypted communication without HTTPS. An attacker who managed to gain machine-in-the-middle position could manipulate, or steal confidential information.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-40729"
},
{
"cve": "CVE-2023-40730",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application lacks sufficient authorization checks. This could allow an attacker to access confidential information, perform administrative functions, or lead to a denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-40730"
},
{
"cve": "CVE-2023-40731",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "summary",
"text": "The affected application allows users to upload arbitrary file types. This could allow an attacker to upload malicious files, that could potentially lead to code tampering.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-40731"
},
{
"cve": "CVE-2023-40732",
"cwe": {
"id": "CWE-613",
"name": "Insufficient Session Expiration"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-40732"
}
]
}
fkie_cve-2022-43958
Vulnerability from fkie_nvd
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf | ||
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf | Mitigation, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | qms_automotive | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:qms_automotive:*:*:*:*:*:*:*:*",
"matchCriteriaId": "495D38E5-5C7F-43C2-997F-D2226C7D0A2C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39), QMS Automotive (All versions \u003c V12.39). User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en QMS Automotive (todas las versiones \u0026lt; V12.39), QMS Automotive (todas las versiones \u0026lt; V12.39). Las credenciales de usuario se almacenan en texto plano en la base de datos sin ning\u00fan mecanismo de hash. Esto podr\u00eda permitir a un atacante obtener acceso a las credenciales y suplantar a otros usuarios."
}
],
"id": "CVE-2022-43958",
"lastModified": "2024-11-21T07:27:24.770",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 5.5,
"source": "productcert@siemens.com",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
},
"published": "2022-11-08T11:15:12.193",
"references": [
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-256"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
ghsa-jqv9-xxr8-r2p9
Vulnerability from github
A vulnerability has been identified in QMS Automotive (All versions). User credentials are stored in plaintext in the database. This could allow an attacker to gain access to credentials and impersonate other users.
{
"affected": [],
"aliases": [
"CVE-2022-43958"
],
"database_specific": {
"cwe_ids": [
"CWE-312"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-11-08T11:15:00Z",
"severity": "CRITICAL"
},
"details": "A vulnerability has been identified in QMS Automotive (All versions). User credentials are stored in plaintext in the database. This could allow an attacker to gain access to credentials and impersonate other users.",
"id": "GHSA-jqv9-xxr8-r2p9",
"modified": "2022-11-09T19:02:22Z",
"published": "2022-11-08T12:00:17Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-43958"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-587547.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"type": "CVSS_V3"
}
]
}
cnvd-2022-75537
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-587547.html
| Name | Siemens QMS Automotive |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2022-43958"
}
},
"description": "QMS Automotive\u63d0\u4f9b\u4e86\u7b80\u5316\u751f\u4ea7\u548cERP\u64cd\u4f5c\u6240\u9700\u7684\u7a0b\u5e8f\u3001\u6d41\u7a0b\u3001\u7ed3\u6784\u548c\u8d44\u6e90\uff0c\u540c\u65f6\u6709\u6548\u5730\u7ba1\u7406\u8d28\u91cf\u95ee\u9898\u3002\n\nSiemens QMS Automotive\u5b58\u5728\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u8bbf\u95ee\u51ed\u636e\u5e76\u5192\u5145\u5176\u4ed6\u7528\u6237\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a \r\nhttps://cert-portal.siemens.com/productcert/html/ssa-587547.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2022-75537",
"openTime": "2022-11-09",
"patchDescription": "QMS Automotive\u63d0\u4f9b\u4e86\u7b80\u5316\u751f\u4ea7\u548cERP\u64cd\u4f5c\u6240\u9700\u7684\u7a0b\u5e8f\u3001\u6d41\u7a0b\u3001\u7ed3\u6784\u548c\u8d44\u6e90\uff0c\u540c\u65f6\u6709\u6548\u5730\u7ba1\u7406\u8d28\u91cf\u95ee\u9898\u3002\r\n\r\nSiemens QMS Automotive\u5b58\u5728\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u8bbf\u95ee\u51ed\u636e\u5e76\u5192\u5145\u5176\u4ed6\u7528\u6237\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens QMS Automotive\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Siemens QMS Automotive"
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-587547.html",
"serverity": "\u9ad8",
"submitTime": "2022-11-09",
"title": "Siemens QMS Automotive\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.