Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-41661 (GCVE-0-2022-41661)
Vulnerability from cvelistv5
- CWE-125 - Out-of-bounds Read
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Siemens | JT2Go |
Version: All versions < V14.1.0.4 |
||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:49:43.627Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-41661", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-04-18T15:22:28.698190Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-21T13:46:57.615Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "JT2Go", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14.1.0.4" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V13.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.2.0.12" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V13.3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.3.0.7" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14.0.0.3" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14.1.0.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-13T08:16:51.110Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-41661", "datePublished": "2022-11-08T00:00:00.000Z", "dateReserved": "2022-09-27T00:00:00.000Z", "dateUpdated": "2025-04-21T13:46:57.615Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-41661\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-11-08T11:15:11.623\",\"lastModified\":\"2024-11-21T07:23:35.297\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones \u0026lt; V14.1.0.4), Teamcenter Visualization V13.2 (Todas las versiones \u0026lt; V13.2.0.12), Teamcenter Visualization V13.3 (Todas las versiones \u0026lt; V13.3.0. 7), Teamcenter Visualization V14.0 (todas las versiones \u0026lt; V14.0.0.3), Teamcenter Visualization V14.1 (todas las versiones \u0026lt; V14.1.0.4). Los productos afectados contienen una vulnerabilidad de lectura fuera de l\u00edmites al analizar un archivo CGM. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"14.1.0.4\",\"matchCriteriaId\":\"FD5EAF75-B0F4-4792-9833-085B9D830FCE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.3.0\",\"versionEndExcluding\":\"13.3.0.7\",\"matchCriteriaId\":\"FB99D790-4F55-48F2-902B-8739CAEC78EE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.0\",\"versionEndExcluding\":\"14.0.0.3\",\"matchCriteriaId\":\"0F811DB6-3650-4BCB-A538-AAECF63EA085\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.1\",\"versionEndExcluding\":\"14.1.0.4\",\"matchCriteriaId\":\"175648D0-81ED-4AC9-AF2D-4C9E93814C36\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T12:49:43.627Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-41661\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-18T15:22:28.698190Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-18T15:22:30.807Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"JT2Go\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V14.1.0.4\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V13.2\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V13.2.0.12\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V13.3\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V13.3.0.7\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V14.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V14.0.0.3\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V14.1\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V14.1.0.4\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-125\", \"description\": \"CWE-125: Out-of-bounds Read\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-06-13T08:16:51.110Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-41661\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-21T13:46:57.615Z\", \"dateReserved\": \"2022-09-27T00:00:00.000Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2022-11-08T00:00:00.000Z\", \"assignerShortName\": \"siemens\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
icsa-22-314-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Siemens Teamcenter Visualization and JT2Go are affected by multiple file parsing vulnerabilities that could be triggered when the application reads malicious TIF, CGM or PDF files. If a user is tricked to open a malicious TIF, CGM or PDF file with the affected products, this could lead the application to crash or potentially lead to arbitrary code execution.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-120378: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-120378.json" }, { "category": "self", "summary": "SSA-120378: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-120378.html" }, { "category": "self", "summary": "SSA-120378: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" }, { "category": "self", "summary": "SSA-120378: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-120378.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-22-314-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-314-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-314-09 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Teamcenter Visualization and JT2Go", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-314-09", "initial_release_date": "2022-11-08T00:00:00.000000Z", "revision_history": [ { "date": "2022-11-08T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2022-12-13T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for Teamcenter Visualization version line V13.3 for CVE-2022-39136" }, { "date": "2023-06-13T00:00:00.000000Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for Teamcenter Visualization version line V13.2" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "4", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "4" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV14.1.0.4", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.2.0.12", "product": { "name": "Teamcenter Visualization V13.2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.3.0.7", "product": { "name": "Teamcenter Visualization V13.3", "product_id": "CSAFPID-0003" } }, { "category": "product_version_range", "name": "\u003e=V13.3.0.7\u003cV13.3.0.8", "product": { "name": "Teamcenter Visualization V13.3", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.3" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.0.0.3", "product": { "name": "Teamcenter Visualization V14.0", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.0" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.1.0.4", "product": { "name": "Teamcenter Visualization V14.1", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.1" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-39136", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to fixed-length heap-based buffer while parsing specially crafted TIF files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.3.0.8 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-39136" }, { "cve": "CVE-2022-41660", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected products contain an out of bounds write vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41660" }, { "cve": "CVE-2022-41661", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41661" }, { "cve": "CVE-2022-41662", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41662" }, { "cve": "CVE-2022-41663", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41663" }, { "cve": "CVE-2022-41664", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41664" } ] }
ICSA-22-314-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Siemens Teamcenter Visualization and JT2Go are affected by multiple file parsing vulnerabilities that could be triggered when the application reads malicious TIF, CGM or PDF files. If a user is tricked to open a malicious TIF, CGM or PDF file with the affected products, this could lead the application to crash or potentially lead to arbitrary code execution.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-120378: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-120378.json" }, { "category": "self", "summary": "SSA-120378: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-120378.html" }, { "category": "self", "summary": "SSA-120378: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" }, { "category": "self", "summary": "SSA-120378: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-120378.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-22-314-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-314-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-314-09 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Teamcenter Visualization and JT2Go", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-314-09", "initial_release_date": "2022-11-08T00:00:00.000000Z", "revision_history": [ { "date": "2022-11-08T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2022-12-13T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for Teamcenter Visualization version line V13.3 for CVE-2022-39136" }, { "date": "2023-06-13T00:00:00.000000Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for Teamcenter Visualization version line V13.2" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "4", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "4" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV14.1.0.4", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.2.0.12", "product": { "name": "Teamcenter Visualization V13.2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.3.0.7", "product": { "name": "Teamcenter Visualization V13.3", "product_id": "CSAFPID-0003" } }, { "category": "product_version_range", "name": "\u003e=V13.3.0.7\u003cV13.3.0.8", "product": { "name": "Teamcenter Visualization V13.3", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.3" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.0.0.3", "product": { "name": "Teamcenter Visualization V14.0", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.0" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.1.0.4", "product": { "name": "Teamcenter Visualization V14.1", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.1" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-39136", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to fixed-length heap-based buffer while parsing specially crafted TIF files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.3.0.8 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-39136" }, { "cve": "CVE-2022-41660", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected products contain an out of bounds write vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41660" }, { "cve": "CVE-2022-41661", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41661" }, { "cve": "CVE-2022-41662", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41662" }, { "cve": "CVE-2022-41663", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41663" }, { "cve": "CVE-2022-41664", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted CGM, TIF or PDF files in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] }, { "category": "vendor_fix", "details": "Update to V13.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.7 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.0.0.3 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V14.1.0.4 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0006" ] } ], "title": "CVE-2022-41664" } ] }
gsd-2022-41661
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-41661", "id": "GSD-2022-41661" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-41661" ], "details": "A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GSD-2022-41661", "modified": "2023-12-13T01:19:33.171674Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-41661", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "JT2Go", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V14.1.0.4" } ] } }, { "product_name": "Teamcenter Visualization V13.2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V13.2.0.12" } ] } }, { "product_name": "Teamcenter Visualization V13.3", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V13.3.0.7" } ] } }, { "product_name": "Teamcenter Visualization V14.0", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V14.0.0.3" } ] } }, { "product_name": "Teamcenter Visualization V14.1", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V14.1.0.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "impact": { "cvss": [ { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-125", "lang": "eng", "value": "CWE-125: Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.1.0.4", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.3.0.7", "versionStartIncluding": "13.3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.0.0.3", "versionStartIncluding": "14.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.1.0.4", "versionStartIncluding": "14.1", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-41661" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-06-13T09:15Z", "publishedDate": "2022-11-08T11:15Z" } } }
CERTFR-2022-AVI-1001
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions antérieures à V2.50 | ||
Siemens | N/A | SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SINUMERIK MC toutes versions | ||
Siemens | N/A | SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0) toutes versions | ||
Siemens | N/A | SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SINUMERIK ONE toutes versions | ||
Siemens | N/A | SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | Parasolid versions antérieures à V34.0.254 | ||
Siemens | N/A | SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions antérieures à V2.50 | ||
Siemens | N/A | Teamcenter Visualization V14.0 versions antérieures à V14.0.0.3 | ||
Siemens | N/A | SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0) versions antérieures à V3.3.19 | ||
Siemens | N/A | Teamcenter Visualization V14.1 versions antérieures à V14.1.0.4 | ||
Siemens | N/A | SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0) toutes versions | ||
Siemens | N/A | SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIMATIC Drive Controller family toutes versions | ||
Siemens | N/A | SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | Teamcenter Visualization V13.3 versions antérieures à V13.3.0.7 | ||
Siemens | N/A | Parasolid versions antérieures à V35.0.184 | ||
Siemens | N/A | JT2Go versions antérieures à V14.1.0.4 | ||
Siemens | N/A | SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIMATIC S7-PLCSIM Advanced toutes versions | ||
Siemens | N/A | QMS Automotive toutes versions | ||
Siemens | N/A | SIMATIC PC Station versions antérieures à V2.1 | ||
Siemens | N/A | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | Parasolid versions antérieures à V34.1.244 | ||
Siemens | N/A | SIMATIC WinCC Runtime Advanced toutes versions | ||
Siemens | N/A | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) toutes versions | ||
Siemens | N/A | SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0) versions antérieures à V3.3.19 | ||
Siemens | N/A | RUGGEDCOM ROS toutes versions | ||
Siemens | N/A | SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0) toutes versions | ||
Siemens | N/A | SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0) versions antérieures à V3.2.19 | ||
Siemens | N/A | SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | SIMATIC S7-1500 Software Controller toutes versions | ||
Siemens | N/A | SINEC NMS versions antérieures à 1.0.3 | ||
Siemens | N/A | SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0) versions antérieures à V3.2.19 |
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions ant\u00e9rieures \u00e0 V2.50", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINUMERIK MC toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINUMERIK ONE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid versions ant\u00e9rieures \u00e0 V34.0.254", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions ant\u00e9rieures \u00e0 V2.50", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Visualization V14.0 versions ant\u00e9rieures \u00e0 V14.0.0.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0) versions ant\u00e9rieures \u00e0 V3.3.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Visualization V14.1 versions ant\u00e9rieures \u00e0 V14.1.0.4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC Drive Controller family toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Visualization V13.3 versions ant\u00e9rieures \u00e0 V13.3.0.7", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid versions ant\u00e9rieures \u00e0 V35.0.184", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "JT2Go versions ant\u00e9rieures \u00e0 V14.1.0.4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-PLCSIM Advanced toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "QMS Automotive toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC PC Station versions ant\u00e9rieures \u00e0 V2.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid versions ant\u00e9rieures \u00e0 V34.1.244", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC Runtime Advanced toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0) versions ant\u00e9rieures \u00e0 V3.3.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROS toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-1500 Software Controller toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC NMS versions ant\u00e9rieures \u00e0 1.0.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2022-37889", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37889" }, { "name": "CVE-2022-39157", "url": "https://www.cve.org/CVERecord?id=CVE-2022-39157" }, { "name": "CVE-2022-41664", "url": "https://www.cve.org/CVERecord?id=CVE-2022-41664" }, { "name": "CVE-2022-41662", "url": "https://www.cve.org/CVERecord?id=CVE-2022-41662" }, { "name": "CVE-2022-37891", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37891" }, { "name": "CVE-2022-41663", "url": "https://www.cve.org/CVERecord?id=CVE-2022-41663" }, { "name": "CVE-2022-37888", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37888" }, { "name": "CVE-2002-20001", "url": "https://www.cve.org/CVERecord?id=CVE-2002-20001" }, { "name": "CVE-2022-43397", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43397" }, { "name": "CVE-2022-43545", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43545" }, { "name": "CVE-2022-37893", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37893" }, { "name": "CVE-2022-37892", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37892" }, { "name": "CVE-2022-39158", "url": "https://www.cve.org/CVERecord?id=CVE-2022-39158" }, { "name": "CVE-2022-37890", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37890" }, { "name": "CVE-2022-43958", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43958" }, { "name": "CVE-2022-37895", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37895" }, { "name": "CVE-2022-37896", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37896" }, { "name": "CVE-2022-41661", "url": "https://www.cve.org/CVERecord?id=CVE-2022-41661" }, { "name": "CVE-2022-43398", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43398" }, { "name": "CVE-2022-39136", "url": "https://www.cve.org/CVERecord?id=CVE-2022-39136" }, { "name": "CVE-2022-30694", "url": "https://www.cve.org/CVERecord?id=CVE-2022-30694" }, { "name": "CVE-2021-42550", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42550" }, { "name": "CVE-2022-37886", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37886" }, { "name": "CVE-2022-38465", "url": "https://www.cve.org/CVERecord?id=CVE-2022-38465" }, { "name": "CVE-2022-37885", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37885" }, { "name": "CVE-2022-37887", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37887" }, { "name": "CVE-2022-37894", "url": "https://www.cve.org/CVERecord?id=CVE-2022-37894" }, { "name": "CVE-2022-43439", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43439" }, { "name": "CVE-2022-41660", "url": "https://www.cve.org/CVERecord?id=CVE-2022-41660" }, { "name": "CVE-2022-43546", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43546" } ], "initial_release_date": "2022-11-08T00:00:00", "last_revision_date": "2022-11-08T00:00:00", "links": [ { "title": "Bulletin de s\u00e9curit\u00e9 Siemens 478960 du 8 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-478960.html" }, { "title": "Bulletin de s\u00e9curit\u00e9 Siemens 568428 du 8 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-568428.html" }, { "title": "Bulletin de s\u00e9curit\u00e9 Siemens 853037 du 8 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-853037.html" }, { "title": "Bulletin de s\u00e9curit\u00e9 Siemens 120378 du 8 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-120378.html" }, { "title": "Bulletin de s\u00e9curit\u00e9 Siemens 587547 du 8 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-587547.html" }, { "title": "Bulletin de s\u00e9curit\u00e9 Siemens 506569 du 8 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-506569.html" }, { "title": "Bulletin de s\u00e9curit\u00e9 Siemens 570294 du 8 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-570294.html" }, { "title": "Bulletin de s\u00e9curit\u00e9 Siemens 787941 du 8 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-787941.html" }, { "title": "Bulletin de s\u00e9curit\u00e9 Siemens 371761 du 8 novembre 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-371761.html" } ], "reference": "CERTFR-2022-AVI-1001", "revisions": [ { "description": "Version initiale", "revision_date": "2022-11-08T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Injection de code indirecte \u00e0 distance (XSS)" }, { "description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens 853037 du 08 novembre 2022", "url": null } ] }
var-202211-0310
Vulnerability from variot
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process. Siemens' JT2Go and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202211-0310", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "jt2go", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.1.0.4" }, { "model": "teamcenter visualization", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.3.0.7" }, { "model": "teamcenter visualization", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "14.1" }, { "model": "teamcenter visualization", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.1.0.4" }, { "model": "teamcenter visualization", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "teamcenter visualization", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "13.3.0" }, { "model": "teamcenter visualization", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0.0.3" }, { "model": "teamcenter visualization", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "jt2go", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022821" }, { "db": "NVD", "id": "CVE-2022-41661" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.1.0.4", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.3.0.7", "versionStartIncluding": "13.3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.0.0.3", "versionStartIncluding": "14.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.1.0.4", "versionStartIncluding": "14.1", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-41661" } ] }, "cve": "CVE-2022-41661", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-41661", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-41661", "trust": 1.8, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2022-41661", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202211-2317", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022821" }, { "db": "NVD", "id": "CVE-2022-41661" }, { "db": "NVD", "id": "CVE-2022-41661" }, { "db": "CNNVD", "id": "CNNVD-202211-2317" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process. Siemens\u0027 JT2Go and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-41661" }, { "db": "JVNDB", "id": "JVNDB-2022-022821" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-41661", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-120378", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-22-314-09", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU93762879", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-022821", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202211-2317", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022821" }, { "db": "NVD", "id": "CVE-2022-41661" }, { "db": "CNNVD", "id": "CNNVD-202211-2317" } ] }, "id": "VAR-202211-0310", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.15799868 }, "last_update_date": "2023-12-18T10:58:13.445000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens JT2Go and Teamcenter Visualization Buffer error vulnerability fix", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=213371" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202211-2317" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-125", "trust": 1.0 }, { "problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022821" }, { "db": "NVD", "id": "CVE-2022-41661" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu93762879/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-41661" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-09" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-41661/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022821" }, { "db": "NVD", "id": "CVE-2022-41661" }, { "db": "CNNVD", "id": "CNNVD-202211-2317" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2022-022821" }, { "db": "NVD", "id": "CVE-2022-41661" }, { "db": "CNNVD", "id": "CNNVD-202211-2317" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-022821" }, { "date": "2022-11-08T11:15:11.623000", "db": "NVD", "id": "CVE-2022-41661" }, { "date": "2022-11-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202211-2317" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-21T01:47:00", "db": "JVNDB", "id": "JVNDB-2022-022821" }, { "date": "2023-06-13T09:15:15.097000", "db": "NVD", "id": "CVE-2022-41661" }, { "date": "2023-06-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202211-2317" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202211-2317" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds read vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022821" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202211-2317" } ], "trust": 0.6 } }
fkie_cve-2022-41661
Vulnerability from fkie_nvd
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
siemens | jt2go | * | |
siemens | teamcenter_visualization | * | |
siemens | teamcenter_visualization | * | |
siemens | teamcenter_visualization | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD5EAF75-B0F4-4792-9833-085B9D830FCE", "versionEndExcluding": "14.1.0.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "matchCriteriaId": "FB99D790-4F55-48F2-902B-8739CAEC78EE", "versionEndExcluding": "13.3.0.7", "versionStartIncluding": "13.3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F811DB6-3650-4BCB-A538-AAECF63EA085", "versionEndExcluding": "14.0.0.3", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "matchCriteriaId": "175648D0-81ED-4AC9-AF2D-4C9E93814C36", "versionEndExcluding": "14.1.0.4", "versionStartIncluding": "14.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones \u0026lt; V14.1.0.4), Teamcenter Visualization V13.2 (Todas las versiones \u0026lt; V13.2.0.12), Teamcenter Visualization V13.3 (Todas las versiones \u0026lt; V13.3.0. 7), Teamcenter Visualization V14.0 (todas las versiones \u0026lt; V14.0.0.3), Teamcenter Visualization V14.1 (todas las versiones \u0026lt; V14.1.0.4). Los productos afectados contienen una vulnerabilidad de lectura fuera de l\u00edmites al analizar un archivo CGM. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual." } ], "id": "CVE-2022-41661", "lastModified": "2024-11-21T07:23:35.297", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-11-08T11:15:11.623", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
ghsa-jj94-vrcq-56wm
Vulnerability from github
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.
{ "affected": [], "aliases": [ "CVE-2022-41661" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-11-08T11:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.4), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GHSA-jj94-vrcq-56wm", "modified": "2022-11-08T19:00:22Z", "published": "2022-11-08T12:00:18Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-41661" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
cnvd-2022-75551
Vulnerability from cnvd
厂商已发布了漏洞修复程序,请及时关注更新: https://cert-portal.siemens.com/productcert/html/ssa-120378.html
Name | ['Siemens Teamcenter Visualization <13.3.0.7', 'Siemens Teamcenter Visualization <14.0.0.3', 'Siemens Teamcenter Visualization <14.1.0.4', 'SIEMENS JT2Go <14.1.0.4'] |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2022-41661" } }, "description": "JT2Go\u662f\u4e00\u4e2a3D JT\u67e5\u770b\u5de5\u5177\uff0c\u5141\u8bb8\u7528\u6237\u67e5\u770bJT\u3001PDF\u3001Solid Edge\u3001PLM XML\u4ee5\u53ca\u53ef\u7528\u7684JT\u3001VFZ\u3001CGM\u548cTIF\u6570\u636e\u3002Teamcenter Visualization\u4f7f\u4f01\u4e1a\u80fd\u591f\u901a\u8fc7\u5168\u9762\u7684\u53ef\u89c6\u5316\u89e3\u51b3\u65b9\u6848\u7cfb\u5217\u589e\u5f3a\u5176\u4ea7\u54c1\u751f\u547d\u5468\u671f\u7ba1\u7406 (PLM) \u73af\u5883\u3002\u8be5\u8f6f\u4ef6\u4f7f\u4f01\u4e1a\u7528\u6237\u80fd\u591f\u5728\u5355\u4e00\u73af\u5883\u4e2d\u8bbf\u95ee\u6587\u6863\u30012D\u56fe\u7eb8\u548c3D\u6a21\u578b\u3002\n\nSiemens JT2Go and Teamcenter Visualization\u5b58\u5728\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002", "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-120378.html", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2022-75551", "openTime": "2022-11-09", "patchDescription": "JT2Go\u662f\u4e00\u4e2a3D JT\u67e5\u770b\u5de5\u5177\uff0c\u5141\u8bb8\u7528\u6237\u67e5\u770bJT\u3001PDF\u3001Solid Edge\u3001PLM XML\u4ee5\u53ca\u53ef\u7528\u7684JT\u3001VFZ\u3001CGM\u548cTIF\u6570\u636e\u3002Teamcenter Visualization\u4f7f\u4f01\u4e1a\u80fd\u591f\u901a\u8fc7\u5168\u9762\u7684\u53ef\u89c6\u5316\u89e3\u51b3\u65b9\u6848\u7cfb\u5217\u589e\u5f3a\u5176\u4ea7\u54c1\u751f\u547d\u5468\u671f\u7ba1\u7406 (PLM) \u73af\u5883\u3002\u8be5\u8f6f\u4ef6\u4f7f\u4f01\u4e1a\u7528\u6237\u80fd\u591f\u5728\u5355\u4e00\u73af\u5883\u4e2d\u8bbf\u95ee\u6587\u6863\u30012D\u56fe\u7eb8\u548c3D\u6a21\u578b\u3002\r\n\r\nSiemens JT2Go and Teamcenter Visualization\u5b58\u5728\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens JT2Go and Teamcenter Visualization\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff08CNVD-2022-75551\uff09\u7684\u8865\u4e01", "products": { "product": [ "Siemens Teamcenter Visualization \u003c13.3.0.7", "Siemens Teamcenter Visualization \u003c14.0.0.3", "Siemens Teamcenter Visualization \u003c14.1.0.4", "SIEMENS JT2Go \u003c14.1.0.4" ] }, "referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-120378.html", "serverity": "\u9ad8", "submitTime": "2022-11-09", "title": "Siemens JT2Go and Teamcenter Visualization\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff08CNVD-2022-75551\uff09" }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.