Summary
A post-auth read-only SQL injection vulnerability allows users to read non-sensitive configuration database contents in the User Portal of Sophos Firewall releases older than version 19.5 GA.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Sophos | Sophos Firewall |
Version: unspecified < 19.5 GA Version: unspecified < 19.0 MR2 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T01:20:57.113Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.sophos.com/en-us/security-advisories/sophos-sa-20221201-sfos-19-5-0" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Sophos Firewall", "vendor": "Sophos", "versions": [ { "lessThan": "19.5 GA", "status": "affected", "version": "unspecified", "versionType": "custom" }, { "lessThan": "19.0 MR2", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A post-auth read-only SQL injection vulnerability allows users to read non-sensitive configuration database contents in the User Portal of Sophos Firewall releases older than version 19.5 GA." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-05T00:00:00", "orgId": "526a354d-e866-4174-ae7d-bac848e5c4c5", "shortName": "Sophos" }, "references": [ { "url": "https://www.sophos.com/en-us/security-advisories/sophos-sa-20221201-sfos-19-5-0" } ] } }, "cveMetadata": { "assignerOrgId": "526a354d-e866-4174-ae7d-bac848e5c4c5", "assignerShortName": "Sophos", "cveId": "CVE-2022-3711", "datePublished": "2022-12-01T00:00:00", "dateReserved": "2022-10-27T00:00:00", "dateUpdated": "2024-08-03T01:20:57.113Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-3711\",\"sourceIdentifier\":\"security-alert@sophos.com\",\"published\":\"2022-12-01T18:15:10.503\",\"lastModified\":\"2024-11-21T07:20:05.413\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A post-auth read-only SQL injection vulnerability allows users to read non-sensitive configuration database contents in the User Portal of Sophos Firewall releases older than version 19.5 GA.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de inyecci\u00f3n SQL de solo lectura posterior a la autenticaci\u00f3n permite a los usuarios leer contenidos de bases de datos de configuraci\u00f3n no confidenciales en el Portal de usuario de versiones de Sophos Firewall anteriores a la versi\u00f3n 19.5 GA.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-alert@sophos.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sophos:xg_firewall_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"19.0\",\"matchCriteriaId\":\"6847B871-B1A5-440F-8B11-93B77D9D13CC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sophos:xg_firewall:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9628D079-44BD-479E-BE63-9BEF824B4E4B\"}]}]}],\"references\":[{\"url\":\"https://www.sophos.com/en-us/security-advisories/sophos-sa-20221201-sfos-19-5-0\",\"source\":\"security-alert@sophos.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.sophos.com/en-us/security-advisories/sophos-sa-20221201-sfos-19-5-0\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.