Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-27653 (GCVE-0-2022-27653)
Vulnerability from cvelistv5
- CWE-787 - Out-of-bounds Write
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | Simcenter Femap |
Version: All versions < V2022.2 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.986Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-10T09:47:03",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-27653",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Simcenter Femap",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-27653",
"datePublished": "2022-05-10T09:47:03",
"dateReserved": "2022-03-22T00:00:00",
"dateUpdated": "2024-08-03T05:32:59.986Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-27653\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-05-20T13:15:15.127\",\"lastModified\":\"2024-11-21T06:56:06.487\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Simcenter Femap (All versions \u003c V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Simcenter Femap (Todas las versiones anteriores a V2022.2). La aplicaci\u00f3n afectada contiene una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analiza archivos .NEU especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15594)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.2\",\"matchCriteriaId\":\"5F2873F9-42DB-4AA4-9697-58C21927B750\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
}
}
CERTFR-2022-AVI-435
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- SICAM P850 versions antérieures à 3.00
- Simcenter Femap versions antérieures à 2022.2
- SIMATIC NET PC Software versions 14.x antérieures à 14 SP1 Update 14
- SIMATIC NET PC Software versions 17.x antérieures à 17 SP1
- SIMATIC Process Historian OPC UA Server versions antérieures à 2020 SP1
- SIMATIC WinCC versions 7.5.x antérieures à V7.5 SP2 Update 8
- SIMATIC CP 442-1 RNA versions antérieures à 1.5.18
- SIMATIC CP 443-1 RNA versions antérieures à 1.5.18
- JT2Go versions antérieures à 13.3.0.3
- Teamcenter Visualization versions 13.3.x antérieures à 13.3.0.3
- Teamcenter Visualization versions 14.0.x antérieures à 14.0.0.1
- Desigo DXR2 versions antérieures à 01.21.142.5-22
- Desigo PXC3 versions antérieures à 01.21.142.4-18
- Desigo PXC4 versions antérieures à 02.20.142.10-10884
- Desigo PXC5 versions antérieures à 02.20.142.10-10884
- RUGGEDCOM RM1224 LTE(4G) EU et RM1224 LTE(4G) NAM versions antérieures à 7.1
- SCALANCE M804PB, M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2), M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2), M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2), M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2), M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), M874-2 (6GK5874-2AA00-2AA2), M874-3 (6GK5874-3AA00-2AA2), M876-3 (EVDO) (6GK5876-3AA02-2BA2), M876-3 (ROK) (6GK5876-3AA02-2EA2), M876-4 (EU) (6GK5876-4AA00-2BA2), M876-4 (NAM) (6GK5876-4AA00-2DA2), MUM856-1 (EU) (6GK5856-2EA00-3DA1), MUM856-1 (RoW) (6GK5856-2EA00-3AA1) et S615 (6GK5615-0AA00-2AA2) versions antérieures à 7.1
- SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) versions antérieures à 3.0.22
- SIMATIC RTU3010C (6NH3112-0BA00-0XX0), RTU3030C (6NH3112-3BA00-0XX0), RTU3031C (6NH3112-3BB00-0XX0) et RTU3041C (6NH3112-4BB00-0XX0) versions antérieures à 5.0.14
- SIPLUS NET CP 1543-1 versions antérieures à 3.0.22
- OpenV2G versions antérieures à 0.9.5
- Teamcenter versions 12.4.x antérieures à 12.4.0.13
- Teamcenter versions 13.0.x antérieures à 13.0.0.9
- Teamcenter versions 13.2.x antérieures à 13.2.0.8
- Teamcenter versions 13.3.x antérieures à 13.3.0.3
- SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0), RF610R ETSI (6GT2811-6BC10-0AA0), RF610R FCC (6GT2811-6BC10-1AA0), RF615R CMIIT (6GT2811-6CC10-2AA0), RF615R ETSI (6GT2811-6CC10-0AA0), RF615R FCC (6GT2811-6CC10-1AA0), RF650R ARIB (6GT2811-6AB20-4AA0), RF650R CMIIT (6GT2811-6AB20-2AA0), RF650R ETSI (6GT2811-6AB20-0AA0), RF650R FCC (6GT2811-6AB20-1AA0), RF680R ARIB (6GT2811-6AA10-4AA0), RF680R CMIIT (6GT2811-6AA10-2AA0), RF680R ETSI (6GT2811-6AA10-0AA0), RF680R FCC (6GT2811-6AA10-1AA0), RF685R ARIB (6GT2811-6CA10-4AA0), RF685R CMIIT (6GT2811-6CA10-2AA0), RF685R ETSI (6GT2811-6CA10-0AA0) et RF685R FCC (6GT2811-6CA10-1AA0) versions 3.0.x antérieures à 4.0
- SIMATIC RF166C (6GT2002-0EE20), RF185C (6GT2002-0JE10), RF186C (6GT2002-0JE20), RF186CI (6GT2002-0JE50), RF188C (6GT2002-0JE40) et RF188CI (6GT2002-0JE60) versions 1.1.x antérieures à 1.3.2
- SIMATIC RF360R (6GT2801-5BA30) versions antérieures à 2.0
En fonction de la vulnérabilité, l'éditeur ne prévoit pas de correctif de sécurité pour les produits suivants :
- SITOP Manager toutes versions
- TeleControl Server Basic versions 3.x
- SIMATIC NET PC Software versions 15.x
- SIMATIC NET PC Software versions 16.x
- SIMATIC WinCC versions 16.x
- SIMATIC WinCC versions 17.x
- SIMATIC WinCC Runtime Professional toutes versions
- SIMATIC WinCC Unified Scada Runtime toutes versions
- SIMATIC PCS 7 versions 9.0.x et antérieures
- SIMATIC PCS 7 versions 9.1.x
- LOGO! CMR family toutes versions
- SIMATIC CP 1545-1 (6GK7545-1GX00-0XE0) toutes versions
- Teamcenter versions 13.1.x
- Teamcenter versions 14.0.x
Se référer aux mesures de contournement listées dans les avis de l'éditeur.
| Vendor | Product | Description |
|---|
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cul\u003e \u003cli\u003eSICAM P850 versions ant\u00e9rieures \u00e0 3.00\u003c/li\u003e \u003cli\u003eSimcenter Femap versions ant\u00e9rieures \u00e0 2022.2\u003c/li\u003e \u003cli\u003eSIMATIC NET PC Software versions 14.x ant\u00e9rieures \u00e0 14 SP1 Update 14\u003c/li\u003e \u003cli\u003eSIMATIC NET PC Software versions 17.x ant\u00e9rieures \u00e0 17 SP1\u003c/li\u003e \u003cli\u003eSIMATIC Process Historian OPC UA Server versions ant\u00e9rieures \u00e0 2020 SP1\u003c/li\u003e \u003cli\u003eSIMATIC WinCC versions 7.5.x ant\u00e9rieures \u00e0 V7.5 SP2 Update 8\u003c/li\u003e \u003cli\u003eSIMATIC CP 442-1 RNA versions ant\u00e9rieures \u00e0 1.5.18\u003c/li\u003e \u003cli\u003eSIMATIC CP 443-1 RNA versions ant\u00e9rieures \u00e0 1.5.18\u003c/li\u003e \u003cli\u003eJT2Go versions ant\u00e9rieures \u00e0 13.3.0.3\u003c/li\u003e \u003cli\u003eTeamcenter Visualization versions 13.3.x ant\u00e9rieures \u00e0 13.3.0.3\u003c/li\u003e \u003cli\u003eTeamcenter Visualization versions 14.0.x ant\u00e9rieures \u00e0 14.0.0.1\u003c/li\u003e \u003cli\u003eDesigo DXR2 versions ant\u00e9rieures \u00e0 01.21.142.5-22\u003c/li\u003e \u003cli\u003eDesigo PXC3 versions ant\u00e9rieures \u00e0 01.21.142.4-18\u003c/li\u003e \u003cli\u003eDesigo PXC4 versions ant\u00e9rieures \u00e0 02.20.142.10-10884\u003c/li\u003e \u003cli\u003eDesigo PXC5 versions ant\u00e9rieures \u00e0 02.20.142.10-10884\u003c/li\u003e \u003cli\u003eRUGGEDCOM RM1224 LTE(4G) EU et RM1224 LTE(4G) NAM versions ant\u00e9rieures \u00e0 7.1\u003c/li\u003e \u003cli\u003eSCALANCE M804PB, M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2), M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2), M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2), M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2), M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), M874-2 (6GK5874-2AA00-2AA2), M874-3 (6GK5874-3AA00-2AA2), M876-3 (EVDO) (6GK5876-3AA02-2BA2), M876-3 (ROK) (6GK5876-3AA02-2EA2), M876-4 (EU) (6GK5876-4AA00-2BA2), M876-4 (NAM) (6GK5876-4AA00-2DA2), MUM856-1 (EU) (6GK5856-2EA00-3DA1), MUM856-1 (RoW) (6GK5856-2EA00-3AA1) et S615 (6GK5615-0AA00-2AA2) versions ant\u00e9rieures \u00e0 7.1\u003c/li\u003e \u003cli\u003eSIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) versions ant\u00e9rieures \u00e0 3.0.22\u003c/li\u003e \u003cli\u003eSIMATIC RTU3010C (6NH3112-0BA00-0XX0), RTU3030C (6NH3112-3BA00-0XX0), RTU3031C (6NH3112-3BB00-0XX0) et RTU3041C (6NH3112-4BB00-0XX0) versions ant\u00e9rieures \u00e0 5.0.14\u003c/li\u003e \u003cli\u003eSIPLUS NET CP 1543-1 versions ant\u00e9rieures \u00e0 3.0.22\u003c/li\u003e \u003cli\u003eOpenV2G versions ant\u00e9rieures \u00e0 0.9.5\u003c/li\u003e \u003cli\u003eTeamcenter versions 12.4.x ant\u00e9rieures \u00e0 12.4.0.13\u003c/li\u003e \u003cli\u003eTeamcenter versions 13.0.x ant\u00e9rieures \u00e0 13.0.0.9\u003c/li\u003e \u003cli\u003eTeamcenter versions 13.2.x ant\u00e9rieures \u00e0 13.2.0.8\u003c/li\u003e \u003cli\u003eTeamcenter versions 13.3.x ant\u00e9rieures \u00e0 13.3.0.3\u003c/li\u003e \u003cli\u003eSIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0), RF610R ETSI (6GT2811-6BC10-0AA0), RF610R FCC (6GT2811-6BC10-1AA0), RF615R CMIIT (6GT2811-6CC10-2AA0), RF615R ETSI (6GT2811-6CC10-0AA0), RF615R FCC (6GT2811-6CC10-1AA0), RF650R ARIB (6GT2811-6AB20-4AA0), RF650R CMIIT (6GT2811-6AB20-2AA0), RF650R ETSI (6GT2811-6AB20-0AA0), RF650R FCC (6GT2811-6AB20-1AA0), RF680R ARIB (6GT2811-6AA10-4AA0), RF680R CMIIT (6GT2811-6AA10-2AA0), RF680R ETSI (6GT2811-6AA10-0AA0), RF680R FCC (6GT2811-6AA10-1AA0), RF685R ARIB (6GT2811-6CA10-4AA0), RF685R CMIIT (6GT2811-6CA10-2AA0), RF685R ETSI (6GT2811-6CA10-0AA0) et RF685R FCC (6GT2811-6CA10-1AA0) versions 3.0.x ant\u00e9rieures \u00e0 4.0\u003c/li\u003e \u003cli\u003eSIMATIC RF166C (6GT2002-0EE20), RF185C (6GT2002-0JE10), RF186C (6GT2002-0JE20), RF186CI (6GT2002-0JE50), RF188C (6GT2002-0JE40) et RF188CI (6GT2002-0JE60) versions 1.1.x ant\u00e9rieures \u00e0 1.3.2\u003c/li\u003e \u003cli\u003eSIMATIC RF360R (6GT2801-5BA30) versions ant\u00e9rieures \u00e0 2.0\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eEn fonction de la vuln\u00e9rabilit\u00e9, l\u0027\u00e9diteur ne pr\u00e9voit pas de correctif de s\u00e9curit\u00e9 pour les produits suivants :\u003c/p\u003e \u003cul\u003e \u003cli\u003eSITOP Manager toutes versions\u003c/li\u003e \u003cli\u003eTeleControl Server Basic versions 3.x\u003c/li\u003e \u003cli\u003eSIMATIC NET PC Software versions 15.x\u003c/li\u003e \u003cli\u003eSIMATIC NET PC Software versions 16.x\u003c/li\u003e \u003cli\u003eSIMATIC WinCC versions 16.x\u003c/li\u003e \u003cli\u003eSIMATIC WinCC versions 17.x\u003c/li\u003e \u003cli\u003eSIMATIC WinCC Runtime Professional toutes versions\u003c/li\u003e \u003cli\u003eSIMATIC WinCC Unified Scada Runtime toutes versions\u003c/li\u003e \u003cli\u003eSIMATIC PCS 7 versions 9.0.x et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eSIMATIC PCS 7 versions 9.1.x\u003c/li\u003e \u003cli\u003eLOGO! CMR family toutes versions\u003c/li\u003e \u003cli\u003eSIMATIC CP 1545-1 (6GK7545-1GX00-0XE0) toutes versions\u003c/li\u003e \u003cli\u003eTeamcenter versions 13.1.x\u003c/li\u003e \u003cli\u003eTeamcenter versions 14.0.x\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eSe r\u00e9f\u00e9rer aux mesures de contournement list\u00e9es dans les avis de l\u0027\u00e9diteur.\u003c/p\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-27653",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27653"
},
{
"name": "CVE-2022-24043",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24043"
},
{
"name": "CVE-2022-29879",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29879"
},
{
"name": "CVE-2022-24044",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24044"
},
{
"name": "CVE-2022-24041",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24041"
},
{
"name": "CVE-2022-27242",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27242"
},
{
"name": "CVE-2021-22901",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22901"
},
{
"name": "CVE-2022-24290",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24290"
},
{
"name": "CVE-2022-29880",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29880"
},
{
"name": "CVE-2022-24045",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24045"
},
{
"name": "CVE-2022-29882",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29882"
},
{
"name": "CVE-2022-24039",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24039"
},
{
"name": "CVE-2022-24042",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24042"
},
{
"name": "CVE-2021-22924",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22924"
},
{
"name": "CVE-2022-29033",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29033"
},
{
"name": "CVE-2022-24040",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24040"
},
{
"name": "CVE-2022-24287",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24287"
},
{
"name": "CVE-2021-41545",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41545"
},
{
"name": "CVE-2022-29873",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29873"
},
{
"name": "CVE-2022-29801",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29801"
},
{
"name": "CVE-2021-40142",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40142"
},
{
"name": "CVE-2022-29874",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29874"
},
{
"name": "CVE-2022-27640",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27640"
},
{
"name": "CVE-2022-29876",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29876"
},
{
"name": "CVE-2022-29877",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29877"
},
{
"name": "CVE-2021-45117",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-45117"
},
{
"name": "CVE-2022-29029",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29029"
},
{
"name": "CVE-2022-29881",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29881"
},
{
"name": "CVE-2022-29032",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29032"
},
{
"name": "CVE-2022-29872",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29872"
},
{
"name": "CVE-2022-29878",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29878"
},
{
"name": "CVE-2021-31340",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31340"
},
{
"name": "CVE-2022-29031",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29031"
},
{
"name": "CVE-2022-29030",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29030"
},
{
"name": "CVE-2022-29028",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29028"
},
{
"name": "CVE-2022-29883",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29883"
}
],
"initial_release_date": "2022-05-10T00:00:00",
"last_revision_date": "2022-05-10T00:00:00",
"links": [],
"reference": "CERTFR-2022-AVI-435",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-05-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-736385 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-736385.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-732250 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-732250.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-321292 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-321292.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-787292 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-787292.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-162616 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-162616.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-553086 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-553086.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-480937 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-480937.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-626968 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-626968.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-363107 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-363107.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-789162 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-789162.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-165073 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-165073.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-662649 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-662649.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-285795 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-285795.html"
}
]
}
ssa-162616
Vulnerability from csaf_siemens
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
}
],
"category": "Siemens Security Advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens Simcenter Femap versions before V2022.2 are affected by an out of bounds write vulnerability that could be triggered when the application reads files in .NEU format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process.\n\nSiemens recommends to update to the latest version line of Simcenter Femap and to avoid opening of untrusted files from unknown sources.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
},
{
"category": "self",
"summary": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-162616.txt"
},
{
"category": "self",
"summary": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-162616.json"
}
],
"title": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2",
"tracking": {
"current_release_date": "2022-05-10T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-162616",
"initial_release_date": "2022-05-10T00:00:00Z",
"revision_history": [
{
"date": "2022-05-10T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V2022.2",
"product": {
"name": "Simcenter Femap",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Simcenter Femap"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-27653",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"references": [
{
"summary": "CVE-2022-27653 - Simcenter Femap",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2022-27653 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-27653.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2022.2 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "mitigation",
"details": "Do not open untrusted .NEU files in Simcenter Femap",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-27653"
}
]
}
gsd-2022-27653
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2022-27653",
"description": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)",
"id": "GSD-2022-27653"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-27653"
],
"details": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)",
"id": "GSD-2022-27653",
"modified": "2023-12-13T01:19:41.287619Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-27653",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Simcenter Femap",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2022.2",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-27653"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-06-01T18:11Z",
"publishedDate": "2022-05-20T13:15Z"
}
}
}
ghsa-c3x6-px6w-wrxq
Vulnerability from github
A vulnerability has been identified in Simcenter Femap (All versions < V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)
{
"affected": [],
"aliases": [
"CVE-2022-27653"
],
"database_specific": {
"cwe_ids": [
"CWE-787"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-05-20T13:15:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)",
"id": "GHSA-c3x6-px6w-wrxq",
"modified": "2022-06-02T00:00:23Z",
"published": "2022-05-21T00:01:03Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-27653"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
fkie_cve-2022-27653
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf | Mitigation, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | simcenter_femap | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5F2873F9-42DB-4AA4-9697-58C21927B750",
"versionEndExcluding": "2022.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Simcenter Femap (Todas las versiones anteriores a V2022.2). La aplicaci\u00f3n afectada contiene una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analiza archivos .NEU especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15594)"
}
],
"id": "CVE-2022-27653",
"lastModified": "2024-11-21T06:56:06.487",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-05-20T13:15:15.127",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
icsa-22-132-14
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
},
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens Simcenter Femap versions before V2022.2 are affected by an out of bounds write vulnerability that could be triggered when the application reads files in .NEU format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process.\n\nSiemens recommends to update to the latest version line of Simcenter Femap and to avoid opening of untrusted files from unknown sources.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-162616.json"
},
{
"category": "self",
"summary": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-162616.txt"
},
{
"category": "self",
"summary": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-132-14 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-132-14.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-132-14 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-14"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Simcenter Femap",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-132-14",
"initial_release_date": "2022-05-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-05-10T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2022.2",
"product": {
"name": "Simcenter Femap",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Simcenter Femap"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-27653",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "CVE-2022-27653 - Simcenter Femap",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2022-27653 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-27653.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2022.2 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "mitigation",
"details": "Do not open untrusted .NEU files in Simcenter Femap",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-27653"
}
]
}
ICSA-22-132-14
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
},
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens Simcenter Femap versions before V2022.2 are affected by an out of bounds write vulnerability that could be triggered when the application reads files in .NEU format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process.\n\nSiemens recommends to update to the latest version line of Simcenter Femap and to avoid opening of untrusted files from unknown sources.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-162616.json"
},
{
"category": "self",
"summary": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-162616.txt"
},
{
"category": "self",
"summary": "SSA-162616: File Parsing Vulnerabilities in Simcenter Femap before V2022.2 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162616.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-132-14 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-132-14.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-132-14 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-14"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Simcenter Femap",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-132-14",
"initial_release_date": "2022-05-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-05-10T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2022.2",
"product": {
"name": "Simcenter Femap",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Simcenter Femap"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-27653",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "CVE-2022-27653 - Simcenter Femap",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2022-27653 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-27653.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2022.2 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "mitigation",
"details": "Do not open untrusted .NEU files in Simcenter Femap",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-27653"
}
]
}
cnvd-2022-36399
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-162616.html
| Name | Siemens Simcenter Femap < V2022.2 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2022-27653"
}
},
"description": "Siemens Simcenter Femap\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u5de5\u7a0b\u5b66\u4eff\u771f\u5e94\u7528\u7a0b\u5e8f\u3002\u7528\u4e8e\u521b\u5efa\u3001\u7f16\u8f91\u548c\u5bfc\u5165/\u91cd\u7528\u590d\u6742\u4ea7\u54c1\u6216\u7cfb\u7edf\u57fa\u4e8e\u7f51\u683c\u7684\u6709\u9650\u5143\u5206\u6790\u6a21\u578b\u3002\n\nSiemens Simcenter Femap\u5b58\u5728\u6587\u4ef6\u89e3\u6790\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-162616.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2022-36399",
"openTime": "2022-05-11",
"patchDescription": "Siemens Simcenter Femap\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u5de5\u7a0b\u5b66\u4eff\u771f\u5e94\u7528\u7a0b\u5e8f\u3002\u7528\u4e8e\u521b\u5efa\u3001\u7f16\u8f91\u548c\u5bfc\u5165/\u91cd\u7528\u590d\u6742\u4ea7\u54c1\u6216\u7cfb\u7edf\u57fa\u4e8e\u7f51\u683c\u7684\u6709\u9650\u5143\u5206\u6790\u6a21\u578b\u3002\r\n\r\nSiemens Simcenter Femap\u5b58\u5728\u6587\u4ef6\u89e3\u6790\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens Simcenter Femap\u6587\u4ef6\u89e3\u6790\u6f0f\u6d1e\uff08CNVD-2022-36399\uff09\u7684\u8865\u4e01",
"products": {
"product": "Siemens Simcenter Femap \u003c V2022.2"
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-162616.html",
"serverity": "\u9ad8",
"submitTime": "2022-05-11",
"title": "Siemens Simcenter Femap\u6587\u4ef6\u89e3\u6790\u6f0f\u6d1e\uff08CNVD-2022-36399\uff09"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.