CVE-2022-24321 (GCVE-0-2022-24321)
Vulnerability from cvelistv5
Published
2022-02-09 22:05
Modified
2024-08-03 04:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
References
| URL | Tags | ||
|---|---|---|---|
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) |
Version: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:07:02.454Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-09T22:05:12",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-24321",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)",
"version": {
"version_data": [
{
"version_value": "ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-24321",
"datePublished": "2022-02-09T22:05:12",
"dateReserved": "2022-02-02T00:00:00",
"dateUpdated": "2024-08-03T04:07:02.454Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-24321\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-02-09T23:15:20.180\",\"lastModified\":\"2024-11-21T06:50:09.953\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)\"},{\"lang\":\"es\",\"value\":\"Una CWE-754: Se presenta una vulnerabilidad de Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales que podr\u00eda causar una denegaci\u00f3n de servicio contra el servidor Geo SCADA cuando se recibe una petici\u00f3n HTTP malformada. Producto afectado: ClearSCADA (todas las versiones), EcoStruxure Geo SCADA Expert 2019 (todas las versiones), EcoStruxure Geo SCADA Expert 2020 (todas las versiones)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:clearscada:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8117E9AF-97C7-4C10-BE59-5341D32667F4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"665F4C4F-CC00-4484-B6FD-5E77EDBCD242\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA51B4B8-FF75-4BAE-A62B-E4B618CC7B10\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…