Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2021-22804 (GCVE-0-2021-22804)
Vulnerability from cvelistv5
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory
URL | Tags | ||
---|---|---|---|
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior) |
Version: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior) |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.504Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-11T17:40:37", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22804", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)", "version": { "version_data": [ { "version_value": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22804", "datePublished": "2022-02-11T17:40:37", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.504Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-22804\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-02-11T18:15:09.400\",\"lastModified\":\"2024-11-21T05:50:42.197\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)\"},{\"lang\":\"es\",\"value\":\"Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n Inapropiada de un Nombre de Ruta a un Directorio Restringido que podr\u00eda causar la divulgaci\u00f3n de archivos arbitrarios que son le\u00eddos en el contexto del usuario que ejecuta IGSS, debido a una falta de comprobaci\u00f3n de los datos suministrados por el usuario en los mensajes de red. Producto afectado: Interactive Graphical SCADA System Data Collector (dc.exe) (versiones V15.0.0.21243 y anteriores)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_collector:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0.0.21243\",\"matchCriteriaId\":\"43B54FDD-0C25-407A-837F-10F321D3F8A1\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
icsa-21-285-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Vyacheslav Moskvin" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to gain code execution, read/delete files, and create arbitrary files.", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities, Critical Manufacturing, Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-285-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-285-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-285-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-285-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Schneider Electric IGSS", "tracking": { "current_release_date": "2021-10-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-285-03", "initial_release_date": "2021-10-12T00:00:00.000000Z", "revision_history": [ { "date": "2021-10-12T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-285-03 Schneider Electric IGSS" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 15.0.0.21243", "product": { "name": "IGSS Data Collector (dc.exe): v15.0.0.21243 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "IGSS Data Collector (dc.exe)" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-22802", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to remote code execution, due to missing length check on user supplied data, when a constructed message is received on the network.CVE-2021-22802 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22802" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends users update to Version 15.0.0.21244 of the IGSS DC module. Please note, dc.exe includes fixes for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or at the IGSS update link.", "product_ids": [ "CSAFPID-0001" ], "url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP" }, { "category": "mitigation", "details": "Users should employ appropriate patching methodologies. Schneider Electric strongly recommends the use of backups as well as an evaluation of the impact of these patches in a test and development environment or an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center if you need assistance removing a patch.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/work/support/contacts.jsp" }, { "category": "mitigation", "details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Only accept incoming connections from machines, which names have been added as a station in the IGSS System Configuration module by setting the registry key called \u201cMatchWinName\u201d to 1 under: \u201cHKEY_CURRENT_USER\\SOFTWARE\\SchneiderElectric\\IGSS32\\V15.00.00\\DC_HKLM\\\u201d", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow the general security recommendation below and verify devices are isolated on a private network and firewalls are configured with strict boundaries for devices that require remote access.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information see Schneider Electric\u0027s security notification: SEVD-2021-285-03", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22803", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "summary", "text": "By sending constructed messages on the network, an attacker could write arbitrary files to folders in context of the DC module that could lead to remote code execution.CVE-2021-22803 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22803" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends users update to Version 15.0.0.21244 of the IGSS DC module. Please note, dc.exe includes fixes for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or at the IGSS update link.", "product_ids": [ "CSAFPID-0001" ], "url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP" }, { "category": "mitigation", "details": "Users should employ appropriate patching methodologies. Schneider Electric strongly recommends the use of backups as well as an evaluation of the impact of these patches in a test and development environment or an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center if you need assistance removing a patch.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/work/support/contacts.jsp" }, { "category": "mitigation", "details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Only accept incoming connections from machines, which names have been added as a station in the IGSS System Configuration module by setting the registry key called \u201cMatchWinName\u201d to 1 under: \u201cHKEY_CURRENT_USER\\SOFTWARE\\SchneiderElectric\\IGSS32\\V15.00.00\\DC_HKLM\\\u201d", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow the general security recommendation below and verify devices are isolated on a private network and firewalls are configured with strict boundaries for devices that require remote access.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information see Schneider Electric\u0027s security notification: SEVD-2021-285-03", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22804", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "An issue exists that could allow disclosure and read access of arbitrary files in the context of the user running IGSS, due to missing validation of user supplied data in network messages.CVE-2021-22804 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22804" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends users update to Version 15.0.0.21244 of the IGSS DC module. Please note, dc.exe includes fixes for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or at the IGSS update link.", "product_ids": [ "CSAFPID-0001" ], "url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP" }, { "category": "mitigation", "details": "Users should employ appropriate patching methodologies. Schneider Electric strongly recommends the use of backups as well as an evaluation of the impact of these patches in a test and development environment or an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center if you need assistance removing a patch.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/work/support/contacts.jsp" }, { "category": "mitigation", "details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Only accept incoming connections from machines, which names have been added as a station in the IGSS System Configuration module by setting the registry key called \u201cMatchWinName\u201d to 1 under: \u201cHKEY_CURRENT_USER\\SOFTWARE\\SchneiderElectric\\IGSS32\\V15.00.00\\DC_HKLM\\\u201d", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow the general security recommendation below and verify devices are isolated on a private network and firewalls are configured with strict boundaries for devices that require remote access.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information see Schneider Electric\u0027s security notification: SEVD-2021-285-03", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22805", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "An issue exists that could allow disclosure and read access of arbitrary files in the context of the user running IGSS, due to missing validation of user supplied data in network messages.CVE-2021-22805 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22805" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends users update to Version 15.0.0.21244 of the IGSS DC module. Please note, dc.exe includes fixes for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or at the IGSS update link.", "product_ids": [ "CSAFPID-0001" ], "url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP" }, { "category": "mitigation", "details": "Users should employ appropriate patching methodologies. Schneider Electric strongly recommends the use of backups as well as an evaluation of the impact of these patches in a test and development environment or an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center if you need assistance removing a patch.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/work/support/contacts.jsp" }, { "category": "mitigation", "details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Only accept incoming connections from machines, which names have been added as a station in the IGSS System Configuration module by setting the registry key called \u201cMatchWinName\u201d to 1 under: \u201cHKEY_CURRENT_USER\\SOFTWARE\\SchneiderElectric\\IGSS32\\V15.00.00\\DC_HKLM\\\u201d", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow the general security recommendation below and verify devices are isolated on a private network and firewalls are configured with strict boundaries for devices that require remote access.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information see Schneider Electric\u0027s security notification: SEVD-2021-285-03", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ICSA-21-285-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Vyacheslav Moskvin" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to gain code execution, read/delete files, and create arbitrary files.", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities, Critical Manufacturing, Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-285-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-285-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-285-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-285-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Schneider Electric IGSS", "tracking": { "current_release_date": "2021-10-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-285-03", "initial_release_date": "2021-10-12T00:00:00.000000Z", "revision_history": [ { "date": "2021-10-12T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-285-03 Schneider Electric IGSS" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 15.0.0.21243", "product": { "name": "IGSS Data Collector (dc.exe): v15.0.0.21243 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "IGSS Data Collector (dc.exe)" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-22802", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to remote code execution, due to missing length check on user supplied data, when a constructed message is received on the network.CVE-2021-22802 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22802" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends users update to Version 15.0.0.21244 of the IGSS DC module. Please note, dc.exe includes fixes for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or at the IGSS update link.", "product_ids": [ "CSAFPID-0001" ], "url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP" }, { "category": "mitigation", "details": "Users should employ appropriate patching methodologies. Schneider Electric strongly recommends the use of backups as well as an evaluation of the impact of these patches in a test and development environment or an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center if you need assistance removing a patch.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/work/support/contacts.jsp" }, { "category": "mitigation", "details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Only accept incoming connections from machines, which names have been added as a station in the IGSS System Configuration module by setting the registry key called \u201cMatchWinName\u201d to 1 under: \u201cHKEY_CURRENT_USER\\SOFTWARE\\SchneiderElectric\\IGSS32\\V15.00.00\\DC_HKLM\\\u201d", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow the general security recommendation below and verify devices are isolated on a private network and firewalls are configured with strict boundaries for devices that require remote access.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information see Schneider Electric\u0027s security notification: SEVD-2021-285-03", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22803", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "summary", "text": "By sending constructed messages on the network, an attacker could write arbitrary files to folders in context of the DC module that could lead to remote code execution.CVE-2021-22803 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22803" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends users update to Version 15.0.0.21244 of the IGSS DC module. Please note, dc.exe includes fixes for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or at the IGSS update link.", "product_ids": [ "CSAFPID-0001" ], "url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP" }, { "category": "mitigation", "details": "Users should employ appropriate patching methodologies. Schneider Electric strongly recommends the use of backups as well as an evaluation of the impact of these patches in a test and development environment or an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center if you need assistance removing a patch.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/work/support/contacts.jsp" }, { "category": "mitigation", "details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Only accept incoming connections from machines, which names have been added as a station in the IGSS System Configuration module by setting the registry key called \u201cMatchWinName\u201d to 1 under: \u201cHKEY_CURRENT_USER\\SOFTWARE\\SchneiderElectric\\IGSS32\\V15.00.00\\DC_HKLM\\\u201d", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow the general security recommendation below and verify devices are isolated on a private network and firewalls are configured with strict boundaries for devices that require remote access.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information see Schneider Electric\u0027s security notification: SEVD-2021-285-03", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22804", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "An issue exists that could allow disclosure and read access of arbitrary files in the context of the user running IGSS, due to missing validation of user supplied data in network messages.CVE-2021-22804 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22804" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends users update to Version 15.0.0.21244 of the IGSS DC module. Please note, dc.exe includes fixes for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or at the IGSS update link.", "product_ids": [ "CSAFPID-0001" ], "url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP" }, { "category": "mitigation", "details": "Users should employ appropriate patching methodologies. Schneider Electric strongly recommends the use of backups as well as an evaluation of the impact of these patches in a test and development environment or an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center if you need assistance removing a patch.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/work/support/contacts.jsp" }, { "category": "mitigation", "details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Only accept incoming connections from machines, which names have been added as a station in the IGSS System Configuration module by setting the registry key called \u201cMatchWinName\u201d to 1 under: \u201cHKEY_CURRENT_USER\\SOFTWARE\\SchneiderElectric\\IGSS32\\V15.00.00\\DC_HKLM\\\u201d", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow the general security recommendation below and verify devices are isolated on a private network and firewalls are configured with strict boundaries for devices that require remote access.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information see Schneider Electric\u0027s security notification: SEVD-2021-285-03", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22805", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "An issue exists that could allow disclosure and read access of arbitrary files in the context of the user running IGSS, due to missing validation of user supplied data in network messages.CVE-2021-22805 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22805" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Schneider Electric recommends users update to Version 15.0.0.21244 of the IGSS DC module. Please note, dc.exe includes fixes for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or at the IGSS update link.", "product_ids": [ "CSAFPID-0001" ], "url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP" }, { "category": "mitigation", "details": "Users should employ appropriate patching methodologies. Schneider Electric strongly recommends the use of backups as well as an evaluation of the impact of these patches in a test and development environment or an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center if you need assistance removing a patch.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/work/support/contacts.jsp" }, { "category": "mitigation", "details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Only accept incoming connections from machines, which names have been added as a station in the IGSS System Configuration module by setting the registry key called \u201cMatchWinName\u201d to 1 under: \u201cHKEY_CURRENT_USER\\SOFTWARE\\SchneiderElectric\\IGSS32\\V15.00.00\\DC_HKLM\\\u201d", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow the general security recommendation below and verify devices are isolated on a private network and firewalls are configured with strict boundaries for devices that require remote access.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information see Schneider Electric\u0027s security notification: SEVD-2021-285-03", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ghsa-v99q-86vr-vhgp
Vulnerability from github
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
{ "affected": [], "aliases": [ "CVE-2021-22804" ], "database_specific": { "cwe_ids": [ "CWE-22" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-02-11T18:15:00Z", "severity": "HIGH" }, "details": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)", "id": "GHSA-v99q-86vr-vhgp", "modified": "2022-02-19T00:01:51Z", "published": "2022-02-12T00:00:44Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22804" }, { "type": "WEB", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "schema_version": "1.4.0", "severity": [] }
fkie_cve-2021-22804
Vulnerability from fkie_nvd
URL | Tags | ||
---|---|---|---|
cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03 | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03 | Patch, Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | interactive_graphical_scada_system_data_collector | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_collector:*:*:*:*:*:*:*:*", "matchCriteriaId": "43B54FDD-0C25-407A-837F-10F321D3F8A1", "versionEndIncluding": "15.0.0.21243", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)" }, { "lang": "es", "value": "Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n Inapropiada de un Nombre de Ruta a un Directorio Restringido que podr\u00eda causar la divulgaci\u00f3n de archivos arbitrarios que son le\u00eddos en el contexto del usuario que ejecuta IGSS, debido a una falta de comprobaci\u00f3n de los datos suministrados por el usuario en los mensajes de red. Producto afectado: Interactive Graphical SCADA System Data Collector (dc.exe) (versiones V15.0.0.21243 y anteriores)" } ], "id": "CVE-2021-22804", "lastModified": "2024-11-21T05:50:42.197", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-11T18:15:09.400", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
cnvd-2022-13074
Vulnerability from cnvd
厂商已发布了漏洞修复程序,请及时关注更新: https://us-cert.cisa.gov/ics/advisories/icsa-21-285-03
Name | Schneider Electric Interactive Graphical SCADA System <=15.0.0.21243 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2021-22804", "cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2021-22804" } }, "description": "Schneider Electric Interactive Graphical SCADA System (IGSS)\u662f\u7528\u4e8e\u76d1\u6d4b\u548c\u63a7\u5236\u5de5\u4e1a\u8fc7\u7a0b\u7684\u5148\u8fdb\u7684SCADA\u7cfb\u7edf\u3002\n\nSchneider Electric Interactive Graphical SCADA System\u5b58\u5728\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u8bfb\u53d6\u4efb\u610f\u6587\u4ef6\u3002", "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://us-cert.cisa.gov/ics/advisories/icsa-21-285-03", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2022-13074", "openTime": "2022-02-22", "patchDescription": "Schneider Electric Interactive Graphical SCADA System (IGSS)\u662f\u7528\u4e8e\u76d1\u6d4b\u548c\u63a7\u5236\u5de5\u4e1a\u8fc7\u7a0b\u7684\u5148\u8fdb\u7684SCADA\u7cfb\u7edf\u3002\r\n\r\nSchneider Electric Interactive Graphical SCADA System\u5b58\u5728\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u8bfb\u53d6\u4efb\u610f\u6587\u4ef6\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Schneider Electric Interactive Graphical SCADA System\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff08CNVD-2022-13074\uff09\u7684\u8865\u4e01", "products": { "product": "Schneider Electric Interactive Graphical SCADA System \u003c=15.0.0.21243" }, "referenceLink": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-03", "serverity": "\u4e2d", "submitTime": "2021-10-13", "title": "Schneider Electric Interactive Graphical SCADA System\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff08CNVD-2022-13074\uff09" }
CERTFR-2021-AVI-772
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
N/A | N/A | IGSS Data Collector (dc.exe) versions antérieures à V15.0.0.21244 | ||
N/A | N/A | fellerLYnk versions antérieures à V2.6.2 | ||
N/A | N/A | micrologiciel TM5CSLC100FS version antérieures v2.57 | ||
N/A | N/A | Conext Advisor 2 Gateway | ||
N/A | N/A | spaceLYnk versions antérieures à V2.6.2 | ||
N/A | N/A | micrologiciel TM5NS31 versions antérieures à 2.79 | ||
N/A | N/A | Conext Advisor 2 Cloud | ||
N/A | N/A | Wiser for KNX versions antérieures à V2.6.2 | ||
N/A | N/A | Modicon M218 logic controller versions antérieures à 5.1.0.8 | ||
N/A | N/A | micrologiciel TM5NEIP1 versions antérieures à 3.12 | ||
N/A | N/A | ConneXium Network Manager | ||
N/A | N/A | Conext Control V2 Gateway | ||
N/A | N/A | micrologiciel TM5CSLC200FS version antérieures v2.57 |
Title | Publication Time | Tags | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "IGSS Data Collector (dc.exe) versions ant\u00e9rieures \u00e0 V15.0.0.21244", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "fellerLYnk versions ant\u00e9rieures \u00e0 V2.6.2", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "micrologiciel TM5CSLC100FS version ant\u00e9rieures v2.57", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Conext Advisor 2 Gateway", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "spaceLYnk versions ant\u00e9rieures \u00e0 V2.6.2", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "micrologiciel TM5NS31 versions ant\u00e9rieures \u00e0 2.79", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Conext Advisor 2 Cloud", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Wiser for KNX versions ant\u00e9rieures \u00e0 V2.6.2", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon M218 logic controller versions ant\u00e9rieures \u00e0 5.1.0.8", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "micrologiciel TM5NEIP1 versions ant\u00e9rieures \u00e0 3.12", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "ConneXium Network Manager", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Conext Control V2 Gateway", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "micrologiciel TM5CSLC200FS version ant\u00e9rieures v2.57", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2020-17438", "url": "https://www.cve.org/CVERecord?id=CVE-2020-17438" }, { "name": "CVE-2019-0685", "url": "https://www.cve.org/CVERecord?id=CVE-2019-0685" }, { "name": "CVE-2020-1472", "url": "https://www.cve.org/CVERecord?id=CVE-2020-1472" }, { "name": "CVE-2020-0601", "url": "https://www.cve.org/CVERecord?id=CVE-2020-0601" }, { "name": "CVE-2019-11135", "url": "https://www.cve.org/CVERecord?id=CVE-2019-11135" }, { "name": "CVE-2019-0803", "url": "https://www.cve.org/CVERecord?id=CVE-2019-0803" }, { "name": "CVE-2021-22801", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22801" }, { "name": "CVE-2020-0609", "url": "https://www.cve.org/CVERecord?id=CVE-2020-0609" }, { "name": "CVE-2021-22802", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22802" }, { "name": "CVE-2019-0859", "url": "https://www.cve.org/CVERecord?id=CVE-2019-0859" }, { "name": "CVE-2020-13987", "url": "https://www.cve.org/CVERecord?id=CVE-2020-13987" }, { "name": "CVE-2020-1020", "url": "https://www.cve.org/CVERecord?id=CVE-2020-1020" }, { "name": "CVE-2020-0610", "url": "https://www.cve.org/CVERecord?id=CVE-2020-0610" }, { "name": "CVE-2020-0938", "url": "https://www.cve.org/CVERecord?id=CVE-2020-0938" }, { "name": "CVE-2020-1350", "url": "https://www.cve.org/CVERecord?id=CVE-2020-1350" }, { "name": "CVE-2021-22800", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22800" }, { "name": "CVE-2021-22804", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22804" }, { "name": "CVE-2020-0796", "url": "https://www.cve.org/CVERecord?id=CVE-2020-0796" }, { "name": "CVE-2021-22803", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22803" }, { "name": "CVE-2021-22806", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22806" }, { "name": "CVE-2019-1040", "url": "https://www.cve.org/CVERecord?id=CVE-2019-1040" }, { "name": "CVE-2021-22805", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22805" } ], "initial_release_date": "2021-10-12T00:00:00", "last_revision_date": "2021-10-12T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-772", "revisions": [ { "description": "Version initiale", "revision_date": "2021-10-12T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-285-04 du 12 octobre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-04" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-285-03 du 12 octobre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-285-02 du 12 octobre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-02" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-285-05 du 12 octobre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-05" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-285-01 du 12 octobre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-285-06 du 12 octobre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-06" } ] }
gsd-2021-22804
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-22804", "description": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)", "id": "GSD-2021-22804" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-22804" ], "details": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)", "id": "GSD-2021-22804", "modified": "2023-12-13T01:23:24.152593Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22804", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)", "version": { "version_data": [ { "version_value": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_collector:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0.0.21243", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22804" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-22" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-02-18T15:16Z", "publishedDate": "2022-02-11T18:15Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.