cve-2020-27008
Vulnerability from cvelistv5
Published
2021-02-09 15:38
Modified
2024-08-04 16:03
Severity ?
Summary
A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PLT files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12209)
Impacted products
Vendor Product Version
Siemens Teamcenter Visualization Version: All versions < V13.1.0.1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:03:23.179Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-235/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.0.1"
            }
          ]
        },
        {
          "product": "Teamcenter Visualization",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.0.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PLT files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12209)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-19T13:51:25",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-235/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-27008",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT2Go",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.0.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter Visualization",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.0.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PLT files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12209)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-235/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-235/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27008",
    "datePublished": "2021-02-09T15:38:20",
    "dateReserved": "2020-10-12T00:00:00",
    "dateUpdated": "2024-08-04T16:03:23.179Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-27008\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-02-09T17:15:14.483\",\"lastModified\":\"2024-11-21T05:20:40.377\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PLT files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12209)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.1.0.1), Teamcenter Visualization (Todas las versiones anteriores a V13.1.0.1).\u0026#xa0;Las aplicaciones afectadas carecen de una comprobaci\u00f3n apropiada de los datos suministrados por el usuario al analizar archivos PLT.\u0026#xa0;Esto podr\u00eda resultar en un acceso a la memoria m\u00e1s all\u00e1 del final de un b\u00fafer asignado.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad para acceder a los datos en el contexto del proceso actual.\u0026#xa0;(ZDI?CAN-12209)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.1.0.1\",\"matchCriteriaId\":\"4FB80DF8-5E85-4072-8999-02EDA895A112\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.1.0.1\",\"matchCriteriaId\":\"0EB3193F-54C0-4678-A22D-A98D2134F9E7\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-235/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-235/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.