{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.990Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CodeMeter", "vendor": "n/a", "versions": [ { "status": "affected", "version": "All versions prior to 6.90, including Version 6.90 or newer only if CodeMeter Runtime is running as server." } ] } ], "descriptions": [ { "lang": "en", "value": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-326", "description": "INADEQUATE ENCRYPTION STRENGTH CWE-326", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-09-16T19:42:12", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-14517", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CodeMeter", "version": { "version_data": [ { "version_value": "All versions prior to 6.90, including Version 6.90 or newer only if CodeMeter Runtime is running as server." } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "INADEQUATE ENCRYPTION STRENGTH CWE-326" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-14517", "datePublished": "2020-09-16T19:42:12", "dateReserved": "2020-06-19T00:00:00", "dateUpdated": "2024-08-04T12:46:34.990Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-14517\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-09-16T20:15:13.647\",\"lastModified\":\"2024-11-21T05:03:26.437\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.\"},{\"lang\":\"es\",\"value\":\"El cifrado del protocolo se puede romper f\u00e1cilmente para CodeMeter (todas las versiones anteriores a 6.90 est\u00e1n afectadas, incluyendo la versi\u00f3n 6.90 o m\u00e1s reciente solo si CodeMeter Runtime es ejecutado como servidor) y el servidor acepta conexiones externas, lo que puede permitir a un atacante comunicarse de forma remota con la API de CodeMeter\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-326\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.90\",\"matchCriteriaId\":\"04ECF3CE-FA64-4B81-B769-84844ED87CF7\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
ICSA-20-203-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Sharon Brizinov", "Tal Keren" ], "organization": "Claroty", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to alter and forge a license file, cause a denial-of-service condition, potentially attain remote code execution, read heap data, and prevent normal operation of third-party software dependent on the CodeMeter.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-20-203-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-203-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-20-203-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-203-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Wibu-Systems CodeMeter (Update F)", "tracking": { "current_release_date": "2022-03-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-20-203-01", "initial_release_date": "2020-08-20T00:00:00.000000Z", "revision_history": [ { "date": "2020-08-20T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-20-203-01P WIBU SYSTEMS AG CodeMeter (Update A) " }, { "date": "2020-09-08T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update A)" }, { "date": "2020-09-17T00:00:00.000000Z", "legacy_version": "B", "number": "3", "summary": "ICSA-20-203-01 Wibu-Systems AG CodeMeter (Update B)" }, { "date": "2020-10-01T00:00:00.000000Z", "legacy_version": "C", "number": "4", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update C)" }, { "date": "2020-10-15T00:00:00.000000Z", "legacy_version": "D", "number": "5", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update D)" }, { "date": "2020-12-03T00:00:00.000000Z", "legacy_version": "E", "number": "6", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update E)" }, { "date": "2021-02-11T00:00:00.000000Z", "legacy_version": "F", "number": "7", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update F)" }, { "date": "2022-03-10T00:00:00.000000Z", "legacy_version": "G", "number": "8", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update G)" } ], "status": "final", "version": "8" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 7.10a", "product": { "name": "CodeMeter: All versions prior to 7.10a are affected by CVE-2020-14509 and CVE-2020-14519", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "CodeMeter" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 6.90", "product": { "name": "CodeMeter: All versions prior to 6.90 are affected by CVE-2020-14515 when using CmActLicense update files with CmActLicense Firm Code", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "CodeMeter" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 7.10a", "product": { "name": "CodeMeter: All versions prior to 7.10a are affected by CVE-2020-14517", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "CodeMeter" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 7.10", "product": { "name": "CodeMeter: All versions prior to 7.10 are affected by CVE-2020-16233", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "CodeMeter" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 6.81", "product": { "name": "CodeMeter: All versions prior to 6.81 are affected by CVE-2020-14513", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "CodeMeter" } ], "category": "vendor", "name": "Wibu-Systems AG" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-14509", "cwe": { "id": "CWE-805", "name": "Buffer Access with Incorrect Length Value" }, "notes": [ { "category": "summary", "text": "Multiple memory corruption vulnerabilities exist where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities.CVE-2020-14509 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14509" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 10.0, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-14517", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "summary", "text": "Protocol encryption can be easily broken and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.CVE-2020-14517 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14517" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 9.4, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-14519", "cwe": { "id": "CWE-346", "name": "Origin Validation Error" }, "notes": [ { "category": "summary", "text": "This vulnerability allows an attacker to use the internal WebSockets API via a specifically crafted Java Script payload, which may allow alteration or creation of license files when combined with CVE-2020-14515.CVE-2020-14519 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14519" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-14513", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "CodeMeter and the software using it may crash while processing a specifically crafted license file due to unverified length fields.CVE-2020-14513 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14513" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-14515", "cwe": { "id": "CWE-347", "name": "Improper Verification of Cryptographic Signature" }, "notes": [ { "category": "summary", "text": "There is an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected.CVE-2020-14515 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14515" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-16233", "cwe": { "id": "CWE-404", "name": "Improper Resource Shutdown or Release" }, "notes": [ { "category": "summary", "text": "An attacker could send a specially crafted packet that could have the server send back packets containing data from the heap.CVE-2020-16233 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-16233" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] } ] }
icsa-20-203-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Sharon Brizinov", "Tal Keren" ], "organization": "Claroty", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to alter and forge a license file, cause a denial-of-service condition, potentially attain remote code execution, read heap data, and prevent normal operation of third-party software dependent on the CodeMeter.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-20-203-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-203-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-20-203-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-203-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Wibu-Systems CodeMeter (Update F)", "tracking": { "current_release_date": "2022-03-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-20-203-01", "initial_release_date": "2020-08-20T00:00:00.000000Z", "revision_history": [ { "date": "2020-08-20T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-20-203-01P WIBU SYSTEMS AG CodeMeter (Update A) " }, { "date": "2020-09-08T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update A)" }, { "date": "2020-09-17T00:00:00.000000Z", "legacy_version": "B", "number": "3", "summary": "ICSA-20-203-01 Wibu-Systems AG CodeMeter (Update B)" }, { "date": "2020-10-01T00:00:00.000000Z", "legacy_version": "C", "number": "4", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update C)" }, { "date": "2020-10-15T00:00:00.000000Z", "legacy_version": "D", "number": "5", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update D)" }, { "date": "2020-12-03T00:00:00.000000Z", "legacy_version": "E", "number": "6", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update E)" }, { "date": "2021-02-11T00:00:00.000000Z", "legacy_version": "F", "number": "7", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update F)" }, { "date": "2022-03-10T00:00:00.000000Z", "legacy_version": "G", "number": "8", "summary": "ICSA-20-203-01 Wibu-Systems CodeMeter (Update G)" } ], "status": "final", "version": "8" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 7.10a", "product": { "name": "CodeMeter: All versions prior to 7.10a are affected by CVE-2020-14509 and CVE-2020-14519", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "CodeMeter" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 6.90", "product": { "name": "CodeMeter: All versions prior to 6.90 are affected by CVE-2020-14515 when using CmActLicense update files with CmActLicense Firm Code", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "CodeMeter" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 7.10a", "product": { "name": "CodeMeter: All versions prior to 7.10a are affected by CVE-2020-14517", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "CodeMeter" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 7.10", "product": { "name": "CodeMeter: All versions prior to 7.10 are affected by CVE-2020-16233", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "CodeMeter" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 6.81", "product": { "name": "CodeMeter: All versions prior to 6.81 are affected by CVE-2020-14513", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "CodeMeter" } ], "category": "vendor", "name": "Wibu-Systems AG" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-14509", "cwe": { "id": "CWE-805", "name": "Buffer Access with Incorrect Length Value" }, "notes": [ { "category": "summary", "text": "Multiple memory corruption vulnerabilities exist where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities.CVE-2020-14509 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14509" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 10.0, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-14517", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "summary", "text": "Protocol encryption can be easily broken and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.CVE-2020-14517 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14517" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 9.4, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-14519", "cwe": { "id": "CWE-346", "name": "Origin Validation Error" }, "notes": [ { "category": "summary", "text": "This vulnerability allows an attacker to use the internal WebSockets API via a specifically crafted Java Script payload, which may allow alteration or creation of license files when combined with CVE-2020-14515.CVE-2020-14519 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14519" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-14513", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "CodeMeter and the software using it may crash while processing a specifically crafted license file due to unverified length fields.CVE-2020-14513 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14513" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-14515", "cwe": { "id": "CWE-347", "name": "Improper Verification of Cryptographic Signature" }, "notes": [ { "category": "summary", "text": "There is an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected.CVE-2020-14515 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-14515" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2020-16233", "cwe": { "id": "CWE-404", "name": "Improper Resource Shutdown or Release" }, "notes": [ { "category": "summary", "text": "An attacker could send a specially crafted packet that could have the server send back packets containing data from the heap.CVE-2020-16233 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-16233" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Wibu-Systems recommends the following:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information please see Wibu-Systems \u0027 security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" }, { "category": "vendor_fix", "details": "For more information on products dependent on the affected CodeMeter see the following vendor security advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-041" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] } ] }
cnvd-2020-51242
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-455843.pdf
Name | ['Siemens Information Server <=2019 SP1', 'Siemens SIMATIC WinCC OA 3.17', 'Siemens SINEC INS', 'Siemens SPPA-S2000 (S7) 3.04', 'Siemens SPPA-S2000 (S7) 3.06', 'Siemens SPPA-T3000 R8.2 SP2', 'Siemens SPPA-S3000 3.05', 'Siemens SPPA-S3000 3.04'] |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2020-14517" } }, "description": "Siemens SIMATIC WinCC OA\uff08Open Architecture\uff09\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u5957SCADA\u7cfb\u7edf\uff0c\u4e5f\u662fHMI\u7cfb\u5217\u7684\u4e00\u4e2a\u7ec4\u6210\u90e8\u5206\u3002\u8be5\u7cfb\u7edf\u4e3b\u8981\u9002\u7528\u4e8e\u8f68\u9053\u4ea4\u901a\u3001\u697c\u5b87\u81ea\u52a8\u5316\u548c\u516c\u5171\u7535\u529b\u4f9b\u5e94\u7b49\u884c\u4e1a\u3002Information Server\u7528\u4e8e\u62a5\u544a\u548c\u53ef\u89c6\u5316\u5b58\u50a8\u5728Process Historian\u4e2d\u7684\u8fc7\u7a0b\u6570\u636e\u3002SINEC INS\u662f\u57fa\u4e8eWeb\u7684\u5e94\u7528\u7a0b\u5e8f\uff0c\u5c06\u5404\u79cd\u7f51\u7edc\u670d\u52a1\u7ec4\u5408\u5728\u4e00\u4e2a\u5de5\u5177\u4e2d\u3002SPPA-S2000\u6a21\u62df\u6838DCS\u7cfb\u7edfSPPA-T2000\u7684\u81ea\u52a8\u5316\u7ec4\u4ef6\uff08S7\uff09\u3002SPPA-S3000\u6a21\u62dfDCS\u7cfb\u7edfSPPA-T3000\u7684\u81ea\u52a8\u5316\u7ec4\u4ef6\u3002SPPA-T3000\u662f\u4e00\u79cd\u5206\u5e03\u5f0f\u63a7\u5236\u7cfb\u7edf\uff0c\u4e3b\u8981\u7528\u4e8e\u5316\u77f3\u548c\u5927\u578b\u53ef\u518d\u751f\u80fd\u6e90\u53d1\u7535\u5382\u3002\n\n\u591a\u6b3eSiemens\u4ea7\u54c1\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u4e0eCodeMeter API\u8fdb\u884c\u8fdc\u7a0b\u901a\u4fe1\u3002", "formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-455843.pdf", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2020-51242", "openTime": "2020-09-10", "patchDescription": "Siemens SIMATIC WinCC OA\uff08Open Architecture\uff09\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u5957SCADA\u7cfb\u7edf\uff0c\u4e5f\u662fHMI\u7cfb\u5217\u7684\u4e00\u4e2a\u7ec4\u6210\u90e8\u5206\u3002\u8be5\u7cfb\u7edf\u4e3b\u8981\u9002\u7528\u4e8e\u8f68\u9053\u4ea4\u901a\u3001\u697c\u5b87\u81ea\u52a8\u5316\u548c\u516c\u5171\u7535\u529b\u4f9b\u5e94\u7b49\u884c\u4e1a\u3002Information Server\u7528\u4e8e\u62a5\u544a\u548c\u53ef\u89c6\u5316\u5b58\u50a8\u5728Process Historian\u4e2d\u7684\u8fc7\u7a0b\u6570\u636e\u3002SINEC INS\u662f\u57fa\u4e8eWeb\u7684\u5e94\u7528\u7a0b\u5e8f\uff0c\u5c06\u5404\u79cd\u7f51\u7edc\u670d\u52a1\u7ec4\u5408\u5728\u4e00\u4e2a\u5de5\u5177\u4e2d\u3002SPPA-S2000\u6a21\u62df\u6838DCS\u7cfb\u7edfSPPA-T2000\u7684\u81ea\u52a8\u5316\u7ec4\u4ef6\uff08S7\uff09\u3002SPPA-S3000\u6a21\u62dfDCS\u7cfb\u7edfSPPA-T3000\u7684\u81ea\u52a8\u5316\u7ec4\u4ef6\u3002SPPA-T3000\u662f\u4e00\u79cd\u5206\u5e03\u5f0f\u63a7\u5236\u7cfb\u7edf\uff0c\u4e3b\u8981\u7528\u4e8e\u5316\u77f3\u548c\u5927\u578b\u53ef\u518d\u751f\u80fd\u6e90\u53d1\u7535\u5382\u3002\r\n\r\n\u591a\u6b3eSiemens\u4ea7\u54c1\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u4e0eCodeMeter API\u8fdb\u884c\u8fdc\u7a0b\u901a\u4fe1\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "\u591a\u6b3eSiemens\u4ea7\u54c1\u52a0\u5bc6\u5f3a\u5ea6\u4e0d\u8db3\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": [ "Siemens Information Server \u003c=2019 SP1", "Siemens SIMATIC WinCC OA 3.17", "Siemens SINEC INS", "Siemens SPPA-S2000 (S7) 3.04", "Siemens SPPA-S2000 (S7) 3.06", "Siemens SPPA-T3000 R8.2 SP2", "Siemens SPPA-S3000 3.05", "Siemens SPPA-S3000 3.04" ] }, "referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-455843.pdf", "serverity": "\u9ad8", "submitTime": "2020-09-09", "title": "\u591a\u6b3eSiemens\u4ea7\u54c1\u52a0\u5bc6\u5f3a\u5ea6\u4e0d\u8db3\u6f0f\u6d1e" }
fkie_cve-2020-14517
Vulnerability from fkie_nvd
URL | Tags | ||
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01 | Third Party Advisory, US Government Resource |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*", "matchCriteriaId": "04ECF3CE-FA64-4B81-B769-84844ED87CF7", "versionEndExcluding": "6.90", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API." }, { "lang": "es", "value": "El cifrado del protocolo se puede romper f\u00e1cilmente para CodeMeter (todas las versiones anteriores a 6.90 est\u00e1n afectadas, incluyendo la versi\u00f3n 6.90 o m\u00e1s reciente solo si CodeMeter Runtime es ejecutado como servidor) y el servidor acepta conexiones externas, lo que puede permitir a un atacante comunicarse de forma remota con la API de CodeMeter" } ], "id": "CVE-2020-14517", "lastModified": "2024-11-21T05:03:26.437", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-09-16T20:15:13.647", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-326" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-327" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CERTFR-2020-AVI-550
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un contournement de la politique de sécurité et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | SPPA-S2000 (S7) | ||
Siemens | N/A | SINEMA Remote Connect | ||
Siemens | N/A | SIMATIC HMI United Comfort Panels | ||
Siemens | N/A | Polarion Subversion Webclient | ||
Siemens | N/A | Siveillance Video Client toutes versions sans le dernier correctif de sécurité | ||
Siemens | N/A | Process Historian | ||
Siemens | N/A | SIMATIC, SIMOTION et SINUMERIK (voir le site du constructeur pour les versions vulnérables, cf. section Documentation) | ||
Siemens | N/A | SIMATIC WinCC OA | ||
Siemens | N/A | SIMATIC HMI Basic Panels 2nd Generation versions antérieures à 14 | ||
Siemens | N/A | SPPA-T3000 | ||
Siemens | N/A | SPPA-S3000 | ||
Siemens | N/A | SIMATIC S7-300 CPU family | ||
Siemens | N/A | License Management Utility (LMU) versions antérieures à 2.4 | ||
Siemens | N/A | SIMATIC RTLS Locating Manager versions antérieures à V2.10.2 | ||
Siemens | N/A | SIMATIC PCS neo | ||
Siemens | N/A | Spectrum Power 4 versions antérieures à 4.70 SP8 | ||
Siemens | N/A | Information Server | ||
Siemens | N/A | SIMATIC HMI Comfort Panels | ||
Siemens | N/A | SINEC INS | ||
Siemens | N/A | SIMATIC HMI Mobile Panels | ||
Siemens | N/A | SIMIT Simulation Platform | ||
Siemens | N/A | SIMATIC S7-400 CPU family |
Title | Publication Time | Tags | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "SPPA-S2000 (S7)", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEMA Remote Connect", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC HMI United Comfort Panels", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Polarion Subversion Webclient", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Video Client toutes versions sans le dernier correctif de s\u00e9curit\u00e9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Process Historian", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC, SIMOTION et SINUMERIK (voir le site du constructeur pour les versions vuln\u00e9rables, cf. section Documentation)", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC OA", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC HMI Basic Panels 2nd Generation versions ant\u00e9rieures \u00e0 14", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SPPA-T3000", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SPPA-S3000", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU family", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "License Management Utility (LMU) versions ant\u00e9rieures \u00e0 2.4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC RTLS Locating Manager versions ant\u00e9rieures \u00e0 V2.10.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC PCS neo", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Spectrum Power 4 versions ant\u00e9rieures \u00e0 4.70 SP8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Information Server", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC HMI Comfort Panels", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC INS", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC HMI Mobile Panels", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMIT Simulation Platform", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-400 CPU family", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2020-15788", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15788" }, { "name": "CVE-2020-14515", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14515" }, { "name": "CVE-2020-14513", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14513" }, { "name": "CVE-2020-10050", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10050" }, { "name": "CVE-2020-10056", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10056" }, { "name": "CVE-2020-15791", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15791" }, { "name": "CVE-2020-15786", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15786" }, { "name": "CVE-2020-15785", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15785" }, { "name": "CVE-2020-14517", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14517" }, { "name": "CVE-2020-14519", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14519" }, { "name": "CVE-2020-15790", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15790" }, { "name": "CVE-2020-15789", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15789" }, { "name": "CVE-2020-10049", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10049" }, { "name": "CVE-2020-15787", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15787" }, { "name": "CVE-2020-14509", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14509" }, { "name": "CVE-2020-10051", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10051" }, { "name": "CVE-2020-15784", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15784" }, { "name": "CVE-2020-16233", "url": "https://www.cve.org/CVERecord?id=CVE-2020-16233" }, { "name": "CVE-2020-0543", "url": "https://www.cve.org/CVERecord?id=CVE-2020-0543" } ], "initial_release_date": "2020-09-08T00:00:00", "last_revision_date": "2022-02-18T00:00:00", "links": [], "reference": "CERTFR-2020-AVI-550", "revisions": [ { "description": "Version initiale", "revision_date": "2020-09-08T00:00:00.000000" }, { "description": "Ajout du lien vers les produits Siemens Energy (https://cert-portal.siemens.com/productcert/html/ssa-455844.html)", "revision_date": "2022-02-18T00:00:00.000000" } ], "risks": [ { "description": "Injection de code indirecte \u00e0 distance (XSS)" }, { "description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un contournement de la\npolitique de s\u00e9curit\u00e9 et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-568969 du 08 septembre 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-455844 du 17 f\u00e9vrier 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-455844.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-455843 du 08 septembre 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-455843.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-251935 du 08 septembre 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-436520 du 08 septembre 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436520.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-381684 du 08 septembre 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381684.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-770698 du 08 septembre 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-770698.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-709003 du 08 septembre 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-709003.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-542525 du 08 septembre 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-534763 du 08 septembre 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-534763.pdf" } ] }
CERTFR-2020-AVI-643
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service, un contournement de la politique de sécurité, une atteinte à l'intégrité des données, une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Schneider Electric | N/A | Acti9 Smartlink SI D et SI B 002.004.002 et versions antérieures | ||
Schneider Electric | N/A | Acti9 PowerTag Link / Link HD 001.008.007 et versions antérieures | ||
Schneider Electric | N/A | Modicon Momentum Ethernet MDI | ||
Schneider Electric | N/A | IFE Gateway toutes versions | ||
Schneider Electric | N/A | Wiser Energy IP module par Schneider Electric (EER31800) toutes versions | ||
Schneider Electric | N/A | TeSys T LTMR08EBD Motor Controller toutes versions | ||
Schneider Electric | N/A | Acti9 Smartlink EL B 1.2.1 et versions antérieures | ||
Schneider Electric | N/A | Modicon Quantum Co-processors ref. 140CPU6 | ||
Schneider Electric | N/A | Premium processors avec Ethernet COPRO intégré (TSXP574634, TSXP575634, TSXP576634) versions antérieures à 6.1 | ||
Schneider Electric | N/A | Gateway Connector par Elko (EKO01827) toutes versions | ||
Schneider Electric | N/A | Network Management Card 3 (NMC3) SmartSlot (modèles AP9640/AP9640J, AP9641/AP9641J) AOS 1.3.0.6 et versions antérieures | ||
Schneider Electric | N/A | Premium communication modules TSXETY4103 versions antérieures à 6.2, TSXETY5103 versions antérieures à 6.4 | ||
Schneider Electric | N/A | Embedded NMC1 (Battery Management System, AP9921X, Rack Automatic Transfer Switches, AP77XX, AP9320, AP9340, AP9361, NetBotz NBRK0200, NetworkAir, InRow) AOS 3.9.2 et version antérieures | ||
Schneider Electric | Modicon M340 | Modicon M340 CPU ref. BMXP34 | ||
Schneider Electric | N/A | ACE850 Sepam communication interface toutes versions | ||
Schneider Electric | N/A | Embedded NMC1 (Metered/Switched Rack PDUs with embedded NMC1, AP78XX, AP79XX) AOS 3.9.2 et versions antérieures | ||
Schneider Electric | N/A | EcoStruxure Building SmartX IP MP et IP RP Controllers toutes versions | ||
Schneider Electric | N/A | Wiser Energy 1.5.0 et versions antérieures | ||
Schneider Electric | N/A | Embedded NMC2 (2G Metered/Switched Rack PDUs with embedded NMC2, AP84XX, AP86XX, AP88XX, AP89XX) | ||
Schneider Electric | N/A | EcoStruxure Machine Expert (précédemment SoMachine et SoMachine Motion) toutes versions | ||
Schneider Electric | N/A | XUPH001 OsSense communication module toutes versions | ||
Schneider Electric | N/A | XGCS850C201 OsiSense RFID compact smart antenna toutes versions | ||
Schneider Electric | N/A | PowerLogic EGX300 Ethernet Gateway toutes versions | ||
Schneider Electric | N/A | Centrale de mesure PowerLogic PM5000 series toutes versions | ||
Schneider Electric | N/A | M340 Communication Ethernet modules BMX NOE 0100 (H) versions antérieures à 3.3, BMX NOE 0110 (H) versions antérieures à 6.5, BMX NOC 0401 versions antérieures à 2.10 | ||
Schneider Electric | Modicon M340 | Modicon M340 Ethernet communication Modules ref. BMXNOC, BMXNOE, BMXNOR | ||
Schneider Electric | N/A | EcoStruxure™Power Monitoring Expert versions 7.x, 8.x et 9.0 | ||
Schneider Electric | N/A | SCADAPack 32 RTUsAll versions 2.24 et versions antérieures | ||
Schneider Electric | N/A | ATV630/650/660/680/6A0/6B0 Altivar Process Drives 2.6IE31 et versions antérieures | ||
Schneider Electric | N/A | ATV340E Altivar Machine Drives 3.1IE23 et versions antérieures | ||
Schneider Electric | N/A | M340 CPUs (BMX P34x) micologiciel versions antérieures à 3.20 | ||
Schneider Electric | N/A | EcoStruxure™Power SCADA Operation with Advanced Reporting and Dashboards Module version 9.0 | ||
Schneider Electric | N/A | Embedded NMC2 (Battery Manager, AP9922, Rack Automatic Transfer Switches, AP44XX, NetBotz NBRK0250) AOS 6.8.8 et version antérieures | ||
Schneider Electric | N/A | Power Manager versions 1.1, 1.2 et 1.3 | ||
Schneider Electric | N/A | AOS 6.8.8 et versions antérieures | ||
Schneider Electric | N/A | ATV930/950/960/980/9A0/9B0 Altivar Process Drives 3.1IE24 et versions antérieures | ||
Schneider Electric | N/A | Acti9 Smartlink IP, Acti9 Smartlink EL B et EL D, Acti9 Smartlink SI B et SI D toutes versions | ||
Schneider Electric | N/A | Smart-UPS et Symmetra UPS Network Management Card 1 (NMC1) SmartSlot (modèles AP9617 (fin de support Nov 2011), AP9619 (fin de support Sep 2012), AP9618 (fin de support Jan 2017), Audio/Video Network Management Enabled products (S20BLK, G50NETB2, G50NETB-20A2)) AOS 3.9.2 et versions antérieures | ||
Schneider Electric | N/A | Modicon Quantum Ethernet communication modules ref.140NOE et 140NOC | ||
Schneider Electric | N/A | eIFE Ethernet Interface pour disjoncteurs MasterPact MTZ drawout toutes versions | ||
Schneider Electric | N/A | EGX150/Link150 Ethernet Gateway toutes versions | ||
Schneider Electric | N/A | EcoStruxure™Energy Expert version 2.0 | ||
Schneider Electric | N/A | Modicon Premium Co-processors ref. TSXP et TSXH | ||
Schneider Electric | N/A | Quantum communication modules 140NOE771x1 versions antérieures à 7.1, 140NOC78x00 versions antérieures à 1.74, 140NOC77101 versions antérieures à 1.08 | ||
Schneider Electric | N/A | Wiser Link 1.5.0 et versions antérieures | ||
Schneider Electric | N/A | Modicon M241 et M251 Logic Controller micrologiciel versions antérieures à 5.0.8.4 | ||
Schneider Electric | N/A | Modicon Premium Ethernet communication modules ref. TSXETY | ||
Schneider Electric | N/A | Andover Continuum controller (NetController 1 (NC1) = modèle CX9900, NetController 2 (NC2) = modèle CX9680, ACX2 = modèles ACX5720 et ACX5740, séries CX9200, séries CX9400, CX9924, CX9702, séries BCX4040, séries BCX9640) toutes versions | ||
Schneider Electric | N/A | IFE Ethernet Interface pour ComPact, PowerPact, et disjoncteurs MasterPact toutes versions | ||
Schneider Electric | N/A | Acti9 PowerTag Link C et Link HD toutes versions | ||
Schneider Electric | N/A | EcoStruxure Machine SCADA Expert toutes versions | ||
Schneider Electric | N/A | Wiser Energy IP module par Clipsal (EER72600) toutes versions | ||
Schneider Electric | N/A | Quantum processors avec Ethernet COPRO intégré 140CPU65xxxxx versions antérieures à 6.1 | ||
Schneider Electric | N/A | ZBRCETH Modbus TCP communication module for ZBRN1 Harmony Hub 02.03 et versions antérieures | ||
Schneider Electric | N/A | ATV6000 Medium Voltage AltivarProcess Drives 1.1IE02 et versions antérieures | ||
Schneider Electric | N/A | StruxureWare™ PowerSCADA Expert with Advanced Reporting and Dashboards Module versions 8.x | ||
Schneider Electric | N/A | E+PLC400, E+PLC100 et E+PLC_Setup toutes versions | ||
Schneider Electric | N/A | TM3BC bus coupler module EIP, SL et CANOpen toutes versions | ||
Schneider Electric | N/A | VW3A3720, VW3A3721 Altivar ProcessCommunication Modules 1.15IE18 et versions antérieures |
Title | Publication Time | Tags | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Acti9 Smartlink SI D et SI B 002.004.002 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Acti9 PowerTag Link / Link HD 001.008.007 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Modicon Momentum Ethernet MDI", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "IFE Gateway toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Wiser Energy IP module par Schneider Electric (EER31800) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "TeSys T LTMR08EBD Motor Controller toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Acti9 Smartlink EL B 1.2.1 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Modicon Quantum Co-processors ref. 140CPU6", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Premium processors avec Ethernet COPRO int\u00e9gr\u00e9 (TSXP574634, TSXP575634, TSXP576634) versions ant\u00e9rieures \u00e0 6.1", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Gateway Connector par Elko (EKO01827) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Network Management Card 3 (NMC3) SmartSlot (mod\u00e8les AP9640/AP9640J, AP9641/AP9641J) AOS 1.3.0.6 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Premium communication modules TSXETY4103 versions ant\u00e9rieures \u00e0 6.2, TSXETY5103 versions ant\u00e9rieures \u00e0 6.4", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Embedded NMC1 (Battery Management System, AP9921X, Rack Automatic Transfer Switches, AP77XX, AP9320, AP9340, AP9361, NetBotz NBRK0200, NetworkAir, InRow) AOS 3.9.2 et version ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Modicon M340 CPU ref. BMXP34", "product": { "name": "Modicon M340", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "ACE850 Sepam communication interface toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Embedded NMC1 (Metered/Switched Rack PDUs with embedded NMC1, AP78XX, AP79XX) AOS 3.9.2 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure Building SmartX IP MP et IP RP Controllers toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Wiser Energy 1.5.0 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Embedded NMC2 (2G Metered/Switched Rack PDUs with embedded NMC2, AP84XX, AP86XX, AP88XX, AP89XX)", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure Machine Expert (pr\u00e9c\u00e9demment SoMachine et SoMachine Motion) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "XUPH001 OsSense communication module toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "XGCS850C201 OsiSense RFID compact smart antenna toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "PowerLogic EGX300 Ethernet Gateway toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Centrale de mesure PowerLogic PM5000 series toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "M340 Communication Ethernet modules BMX NOE 0100 (H) versions ant\u00e9rieures \u00e0 3.3, BMX NOE 0110 (H) versions ant\u00e9rieures \u00e0 6.5, BMX NOC 0401 versions ant\u00e9rieures \u00e0 2.10", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Modicon M340 Ethernet communication Modules ref. BMXNOC, BMXNOE, BMXNOR", "product": { "name": "Modicon M340", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure\u2122Power Monitoring Expert versions 7.x, 8.x et 9.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "SCADAPack 32 RTUsAll versions 2.24 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "ATV630/650/660/680/6A0/6B0 Altivar Process Drives 2.6IE31 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "ATV340E Altivar Machine Drives 3.1IE23 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "M340 CPUs (BMX P34x) micologiciel versions ant\u00e9rieures \u00e0 3.20", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure\u2122Power SCADA Operation with Advanced Reporting and Dashboards Module version 9.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Embedded NMC2 (Battery Manager, AP9922, Rack Automatic Transfer Switches, AP44XX, NetBotz NBRK0250) AOS 6.8.8 et version ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Power Manager versions 1.1, 1.2 et 1.3", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "AOS 6.8.8 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "ATV930/950/960/980/9A0/9B0 Altivar Process Drives 3.1IE24 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Acti9 Smartlink IP, Acti9 Smartlink EL B et EL D, Acti9 Smartlink SI B et SI D toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Smart-UPS et Symmetra UPS Network Management Card 1 (NMC1) SmartSlot (mod\u00e8les AP9617 (fin de support Nov 2011), AP9619 (fin de support Sep 2012), AP9618 (fin de support Jan 2017), Audio/Video Network Management Enabled products (S20BLK, G50NETB2, G50NETB-20A2)) AOS 3.9.2 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Modicon Quantum Ethernet communication modules ref.140NOE et 140NOC", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "eIFE Ethernet Interface pour disjoncteurs MasterPact MTZ drawout toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EGX150/Link150 Ethernet Gateway toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure\u2122Energy Expert version 2.0", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Modicon Premium Co-processors ref. TSXP et TSXH", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Quantum communication modules 140NOE771x1 versions ant\u00e9rieures \u00e0 7.1, 140NOC78x00 versions ant\u00e9rieures \u00e0 1.74, 140NOC77101 versions ant\u00e9rieures \u00e0 1.08", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Wiser Link 1.5.0 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Modicon M241 et M251 Logic Controller micrologiciel versions ant\u00e9rieures \u00e0 5.0.8.4", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Modicon Premium Ethernet communication modules ref. TSXETY", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Andover Continuum controller (NetController 1 (NC1) = mod\u00e8le CX9900, NetController 2 (NC2) = mod\u00e8le CX9680, ACX2 = mod\u00e8les ACX5720 et ACX5740, s\u00e9ries CX9200, s\u00e9ries CX9400, CX9924, CX9702, s\u00e9ries BCX4040, s\u00e9ries BCX9640) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "IFE Ethernet Interface pour ComPact, PowerPact, et disjoncteurs MasterPact toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Acti9 PowerTag Link C et Link HD toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure Machine SCADA Expert toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Wiser Energy IP module par Clipsal (EER72600) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Quantum processors avec Ethernet COPRO int\u00e9gr\u00e9 140CPU65xxxxx versions ant\u00e9rieures \u00e0 6.1", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "ZBRCETH Modbus TCP communication module for ZBRN1 Harmony Hub 02.03 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "ATV6000 Medium Voltage AltivarProcess Drives 1.1IE02 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "StruxureWare\u2122 PowerSCADA Expert with Advanced Reporting and Dashboards Module versions 8.x", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "E+PLC400, E+PLC100 et E+PLC_Setup toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "TM3BC bus coupler module EIP, SL et CANOpen toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "VW3A3720, VW3A3721 Altivar ProcessCommunication Modules 1.15IE18 et versions ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2020-7547", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7547" }, { "name": "CVE-2020-14515", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14515" }, { "name": "CVE-2020-14513", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14513" }, { "name": "CVE-2020-7548", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7548" }, { "name": "CVE-2020-7545", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7545" }, { "name": "CVE-2017-6028", "url": "https://www.cve.org/CVERecord?id=CVE-2017-6028" }, { "name": "CVE-2020-14517", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14517" }, { "name": "CVE-2020-14519", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14519" }, { "name": "CVE-2020-7546", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7546" }, { "name": "CVE-2020-14509", "url": "https://www.cve.org/CVERecord?id=CVE-2020-14509" }, { "name": "CVE-2020-16233", "url": "https://www.cve.org/CVERecord?id=CVE-2020-16233" }, { "name": "CVE-2020-7533", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7533" }, { "name": "CVE-2020-11898", "url": "https://www.cve.org/CVERecord?id=CVE-2020-11898" }, { "name": "CVE-2020-11896", "url": "https://www.cve.org/CVERecord?id=CVE-2020-11896" } ], "initial_release_date": "2020-10-14T00:00:00", "last_revision_date": "2020-10-14T00:00:00", "links": [], "reference": "CERTFR-2020-AVI-643", "revisions": [ { "description": "Version initiale", "revision_date": "2020-10-14T00:00:00.000000" } ], "risks": [ { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "D\u00e9ni de service" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Elles permettent \u00e0 un attaquant de provoquer une\nex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service, un\ncontournement de la politique de s\u00e9curit\u00e9, une atteinte \u00e0 l\u0027int\u00e9grit\u00e9\ndes donn\u00e9es, une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-287-02 du 10 octobre 2020", "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-02/" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2017-075-03 du 10 octobre 2020", "url": "https://www.se.com/ww/en/download/document/SEVD-2017-075-03/" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-287-03 du 10 octobre 2020", "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-287-04 du 10 octobre 2020", "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-287-01 du 10 octobre 2020", "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-01/" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-175-01 du 10 octobre 2020", "url": "https://www.se.com/ww/en/download/document/SEVD-2020-175-01/" } ] }
ghsa-hqvx-g6jw-22pw
Vulnerability from github
Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.
{ "affected": [], "aliases": [ "CVE-2020-14517" ], "database_specific": { "cwe_ids": [ "CWE-327" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2020-09-16T20:15:00Z", "severity": "CRITICAL" }, "details": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.", "id": "GHSA-hqvx-g6jw-22pw", "modified": "2022-05-24T17:28:24Z", "published": "2022-05-24T17:28:24Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-14517" }, { "type": "WEB", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" } ], "schema_version": "1.4.0", "severity": [] }
var-202009-1544
Vulnerability from variot
Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API. CodeMeter Contains a cryptographic vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SIMATIC WinCC OA (Open Architecture) is a set of SCADA system of Siemens (Siemens), Germany, and it is also an integral part of HMI series. The system is mainly suitable for industries such as rail transit, building automation and public power supply. Information Server is used to report and visualize the process data stored in the Process Historian. SINEC INS is a web-based application that combines various network services in one tool. SPPA-S2000 simulates the automation component (S7) of the nuclear DCS system SPPA-T2000. SPPA-S3000 simulates the automation components of DCS system SPPA-T3000. SPPA-T3000 is a distributed control system, mainly used in fossil and large renewable energy power plants.
Many Siemens products have security vulnerabilities. Attackers can use the vulnerability to communicate with CodeMeter API remotely
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202009-1544", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "codemeter", "scope": "lt", "trust": 1.0, "vendor": "wibu", "version": "6.90" }, { "model": "codemeter", "scope": null, "trust": 0.8, "vendor": "wibu", "version": null }, { "model": "codemeter", "scope": "eq", "trust": 0.8, "vendor": "wibu", "version": null }, { "model": "codemeter", "scope": "eq", "trust": 0.8, "vendor": "wibu", "version": "6.90" }, { "model": "information server sp1", "scope": "lte", "trust": 0.6, "vendor": "siemens", "version": "\u003c=2019" }, { "model": "simatic wincc oa", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.17" }, { "model": "sinec ins", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sppa-s2000", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.04" }, { "model": "sppa-s2000", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.06" }, { "model": "sppa-t3000 r8.2 sp2", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sppa-s3000", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.05" }, { "model": "sppa-s3000", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "3.04" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "NVD", "id": "CVE-2020-14517" } ] }, "cve": "CVE-2020-14517", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2020-14517", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.7, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2020-51242", "impactScore": 9.5, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2020-14517", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-14517", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-14517", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2020-14517", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2020-51242", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202009-489", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "CNNVD", "id": "CNNVD-202009-489" }, { "db": "NVD", "id": "CVE-2020-14517" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API. CodeMeter Contains a cryptographic vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SIMATIC WinCC OA (Open Architecture) is a set of SCADA system of Siemens (Siemens), Germany, and it is also an integral part of HMI series. The system is mainly suitable for industries such as rail transit, building automation and public power supply. Information Server is used to report and visualize the process data stored in the Process Historian. SINEC INS is a web-based application that combines various network services in one tool. SPPA-S2000 simulates the automation component (S7) of the nuclear DCS system SPPA-T2000. SPPA-S3000 simulates the automation components of DCS system SPPA-T3000. SPPA-T3000 is a distributed control system, mainly used in fossil and large renewable energy power plants. \n\r\n\r\nMany Siemens products have security vulnerabilities. Attackers can use the vulnerability to communicate with CodeMeter API remotely", "sources": [ { "db": "NVD", "id": "CVE-2020-14517" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "CNVD", "id": "CNVD-2020-51242" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14517", "trust": 3.8 }, { "db": "ICS CERT", "id": "ICSA-20-203-01", "trust": 2.4 }, { "db": "JVN", "id": "JVNVU90770748", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU94568336", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-011222", "trust": 0.8 }, { "db": "SIEMENS", "id": "SSA-455843", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2020-51242", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.3076.2", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.3076.3", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.3076", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022021806", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202009-489", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "CNNVD", "id": "CNNVD-202009-489" }, { "db": "NVD", "id": "CVE-2020-14517" } ] }, "id": "VAR-202009-1544", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" } ], "trust": 1.3593294842857142 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" } ] }, "last_update_date": "2024-11-23T21:26:24.181000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "CodeMeter", "trust": 0.8, "url": "https://www.wibu.com/products/codemeter.html" }, { "title": "Patch for Vulnerabilities in insufficient encryption strength of many Siemens products", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/233344" }, { "title": "ARC and MATIO Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=127910" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "CNNVD", "id": "CNNVD-202009-489" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-326", "trust": 1.0 }, { "problemtype": "CWE-327", "trust": 1.0 }, { "problemtype": "Inadequate encryption strength (CWE-326) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "NVD", "id": "CVE-2020-14517" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14517" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu94568336/" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90770748/" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-455843.pdf" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-simatic-six-vulnerabilities-via-wibu-systems-codemeter-runtime-33282" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022021806" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.3076.2/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.3076.3/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.3076/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "CNNVD", "id": "CNNVD-202009-489" }, { "db": "NVD", "id": "CVE-2020-14517" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-51242" }, { "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "db": "CNNVD", "id": "CNNVD-202009-489" }, { "db": "NVD", "id": "CVE-2020-14517" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-09-10T00:00:00", "db": "CNVD", "id": "CNVD-2020-51242" }, { "date": "2021-03-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "date": "2020-09-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202009-489" }, { "date": "2020-09-16T20:15:13.647000", "db": "NVD", "id": "CVE-2020-14517" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-09-10T00:00:00", "db": "CNVD", "id": "CNVD-2020-51242" }, { "date": "2022-03-15T05:10:00", "db": "JVNDB", "id": "JVNDB-2020-011222" }, { "date": "2022-02-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202009-489" }, { "date": "2024-11-21T05:03:26.437000", "db": "NVD", "id": "CVE-2020-14517" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202009-489" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "CodeMeter\u00a0 Vulnerability in cryptography", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-011222" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "encryption problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202009-489" } ], "trust": 0.6 } }
gsd-2020-14517
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2020-14517", "description": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.", "id": "GSD-2020-14517" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-14517" ], "details": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.", "id": "GSD-2020-14517", "modified": "2023-12-13T01:22:00.294351Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-14517", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CodeMeter", "version": { "version_data": [ { "version_value": "All versions prior to 6.90, including Version 6.90 or newer only if CodeMeter Runtime is running as server." } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "INADEQUATE ENCRYPTION STRENGTH CWE-326" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.90", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-14517" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-327" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2021-11-04T18:15Z", "publishedDate": "2020-09-16T20:15Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.