Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2013-3634 (GCVE-0-2013-3634)
Vulnerability from cvelistv5
- n/a
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:14:56.585Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2013-05-24T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-12-12T19:08:46",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3634",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-3634",
"datePublished": "2013-05-24T20:00:00",
"dateReserved": "2013-05-22T00:00:00",
"dateUpdated": "2024-08-06T16:14:56.585Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2013-3634\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2013-05-24T20:55:01.767\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la familia de conmutadores SCALANCE X-200 (incluidas las variantes SIPLUS NET) (Versiones anteriores a la versi\u00f3n V5.0.0 para CVE-2013-3633 y versiones anteriores a la versi\u00f3n V4.5.0 para CVE-2013-3634), conmutador SCALANCE X-200IRT familia (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a la versi\u00f3n V5.1.0). La implementaci\u00f3n de SNMPv3 no verifica suficientemente las credenciales de usuario. Por lo tanto, un atacante puede ejecutar comandos SNMP sin las credenciales correctas.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x200irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.0.0\",\"matchCriteriaId\":\"50D308F8-83C2-4404-9C12-7A033006A350\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B9CBC72-92D9-4B3A-884F-33124C457016\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3268CF75-6DAB-416A-B19B-2A8F95C268CF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x201-3p_irt:-:-:pro:*:*:*:*:*\",\"matchCriteriaId\":\"21095E8E-A67B-448C-90B1-6234D931C005\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A8B1D979-038F-42F4-AB7D-E0664D051B4E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CEB62730-E759-455A-A308-F9DB084B35B5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x202-2p_irt:-:-:pro:*:*:*:*:*\",\"matchCriteriaId\":\"39CAF419-AB8D-4F79-A5E7-602A77D55E65\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6716DCDE-BD3F-4BA2-A66A-A0C14C6A3C15\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x204irt:-:-:pro:*:*:*:*:*\",\"matchCriteriaId\":\"BB688C82-7454-4FD0-B484-C400E7FF4898\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"57E5489B-277A-4D02-B4AB-4DB65969EED2\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
var-201305-0215
Vulnerability from variot
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials. Siemens Scalance X200 IRT Switch firmware SNMPv3 The function does not properly validate the credentials, so any SNMP A command execution vulnerability exists.By using information related to the user name by a third party, any SNMP The command may be executed. The Siemens Scalance X200 series switches can be used to connect industrial components such as PLCs or HMIs. Note: Limited information is currently available regarding this issue. We will update this BID as more information emerges. There is an input validation error vulnerability in Siemens SCALANCE X-200 versions earlier than V4.5.0 and SCALANCE X-200IRT versions earlier than V5.1.0. The vulnerability stems from the failure of the network system or product to properly validate the input data
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201305-0215",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance x200irt",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "5.0.0"
},
{
"model": "scalance x204irt",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x202-2irt",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x202-2p irt",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x201-3p irt",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x200-4p irt",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204irt",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x200 irt",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "5.1.0"
},
{
"model": "scalance x200-4pirt",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x201-3p irt",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "none"
},
{
"model": "scalance x201-3p irt",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "pro"
},
{
"model": "scalance x202-2irt",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "scalance x202-2p irt",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "none"
},
{
"model": "scalance x202-2p irt",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "pro"
},
{
"model": "scalance x204irt",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "none"
},
{
"model": "scalance x204irt",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "pro"
},
{
"model": "scalance xf204irt",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "scalance series switches",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "x-200"
},
{
"model": "scalance x200irt",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "5.0.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "scalance x204irt",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "scalance x202 2p irt",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "scalance x201 3p irt",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "scalance x202 2irt",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "scalance x200 4p irt",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "scalance xf204irt",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "scalance x200irt",
"version": "5.0.0"
}
],
"sources": [
{
"db": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
},
{
"db": "CNNVD",
"id": "CNNVD-201305-539"
},
{
"db": "NVD",
"id": "CVE-2013-3634"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:siemens:scalance_x200irt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:scalance_x200-4p_irt",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:scalance_x201-3p_irt",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:scalance_x202-2irt",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:scalance_x202-2p_irt",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:scalance_x204irt",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:scalance_xf204irt",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The vendor reported this issue.",
"sources": [
{
"db": "BID",
"id": "60168"
}
],
"trust": 0.3
},
"cve": "CVE-2013-3634",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2013-3634",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2013-06391",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "ee998b48-2352-11e6-abef-000c29c66e3d",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-63636",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2013-3634",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2013-3634",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2013-06391",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201305-539",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-63636",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"db": "VULHUB",
"id": "VHN-63636"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
},
{
"db": "CNNVD",
"id": "CNNVD-201305-539"
},
{
"db": "NVD",
"id": "CVE-2013-3634"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials. Siemens Scalance X200 IRT Switch firmware SNMPv3 The function does not properly validate the credentials, so any SNMP A command execution vulnerability exists.By using information related to the user name by a third party, any SNMP The command may be executed. The Siemens Scalance X200 series switches can be used to connect industrial components such as PLCs or HMIs. \nNote: Limited information is currently available regarding this issue. We will update this BID as more information emerges. There is an input validation error vulnerability in Siemens SCALANCE X-200 versions earlier than V4.5.0 and SCALANCE X-200IRT versions earlier than V5.1.0. The vulnerability stems from the failure of the network system or product to properly validate the input data",
"sources": [
{
"db": "NVD",
"id": "CVE-2013-3634"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
},
{
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"db": "BID",
"id": "60168"
},
{
"db": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-63636"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2013-3634",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-170686",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-13-149-01",
"trust": 1.4
},
{
"db": "BID",
"id": "60168",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201305-539",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2013-06391",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-13-169-01",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002823",
"trust": 0.8
},
{
"db": "SECUNIA",
"id": "53519",
"trust": 0.6
},
{
"db": "IVD",
"id": "EE998B48-2352-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "SEEBUG",
"id": "SSVID-89661",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-63636",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"db": "VULHUB",
"id": "VHN-63636"
},
{
"db": "BID",
"id": "60168"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
},
{
"db": "CNNVD",
"id": "CNNVD-201305-539"
},
{
"db": "NVD",
"id": "CVE-2013-3634"
}
]
},
"id": "VAR-201305-0215",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"db": "VULHUB",
"id": "VHN-63636"
}
],
"trust": 1.4751035300000002
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-06391"
}
]
},
"last_update_date": "2024-11-23T22:08:30.972000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-170686",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-170686.pdf"
},
{
"title": "Siemens Scalance X200 Series Switch SNMPv3 Remote Security Bypass Vulnerability Patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/34397"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-63636"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
},
{
"db": "NVD",
"id": "CVE-2013-3634"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-3634"
},
{
"trust": 0.8,
"url": "http://ics-cert.us-cert.gov/advisories/icsa-13-149-01"
},
{
"trust": 0.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-13-169-01"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-3634"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/53519/"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-170686.pdf"
},
{
"trust": 0.6,
"url": "https://www.us-cert.gov/ics/advisories/icsa-13-149-01"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"db": "VULHUB",
"id": "VHN-63636"
},
{
"db": "BID",
"id": "60168"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
},
{
"db": "CNNVD",
"id": "CNNVD-201305-539"
},
{
"db": "NVD",
"id": "CVE-2013-3634"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"db": "VULHUB",
"id": "VHN-63636"
},
{
"db": "BID",
"id": "60168"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
},
{
"db": "CNNVD",
"id": "CNNVD-201305-539"
},
{
"db": "NVD",
"id": "CVE-2013-3634"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-05-31T00:00:00",
"db": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d"
},
{
"date": "2013-05-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"date": "2013-05-24T00:00:00",
"db": "VULHUB",
"id": "VHN-63636"
},
{
"date": "2013-05-24T00:00:00",
"db": "BID",
"id": "60168"
},
{
"date": "2013-05-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002823"
},
{
"date": "2013-05-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201305-539"
},
{
"date": "2013-05-24T20:55:01.767000",
"db": "NVD",
"id": "CVE-2013-3634"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-05-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-06391"
},
{
"date": "2019-12-12T00:00:00",
"db": "VULHUB",
"id": "VHN-63636"
},
{
"date": "2013-06-19T06:37:00",
"db": "BID",
"id": "60168"
},
{
"date": "2013-06-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002823"
},
{
"date": "2019-12-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201305-539"
},
{
"date": "2024-11-21T01:54:01.750000",
"db": "NVD",
"id": "CVE-2013-3634"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201305-539"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens Scalance X200 IRT Switch SNMPv3 Any in function SNMP Command execution vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2013-002823"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation error",
"sources": [
{
"db": "IVD",
"id": "ee998b48-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201305-539"
}
],
"trust": 0.8
}
}
fkie_cve-2013-3634
Vulnerability from fkie_nvd
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_x200irt_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "50D308F8-83C2-4404-9C12-7A033006A350",
"versionEndIncluding": "5.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8B9CBC72-92D9-4B3A-884F-33124C457016",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3268CF75-6DAB-416A-B19B-2A8F95C268CF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:-:pro:*:*:*:*:*",
"matchCriteriaId": "21095E8E-A67B-448C-90B1-6234D931C005",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A8B1D979-038F-42F4-AB7D-E0664D051B4E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CEB62730-E759-455A-A308-F9DB084B35B5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_x202-2p_irt:-:-:pro:*:*:*:*:*",
"matchCriteriaId": "39CAF419-AB8D-4F79-A5E7-602A77D55E65",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6716DCDE-BD3F-4BA2-A66A-A0C14C6A3C15",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_x204irt:-:-:pro:*:*:*:*:*",
"matchCriteriaId": "BB688C82-7454-4FD0-B484-C400E7FF4898",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
"matchCriteriaId": "57E5489B-277A-4D02-B4AB-4DB65969EED2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en la familia de conmutadores SCALANCE X-200 (incluidas las variantes SIPLUS NET) (Versiones anteriores a la versi\u00f3n V5.0.0 para CVE-2013-3633 y versiones anteriores a la versi\u00f3n V4.5.0 para CVE-2013-3634), conmutador SCALANCE X-200IRT familia (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a la versi\u00f3n V5.1.0). La implementaci\u00f3n de SNMPv3 no verifica suficientemente las credenciales de usuario. Por lo tanto, un atacante puede ejecutar comandos SNMP sin las credenciales correctas."
}
],
"id": "CVE-2013-3634",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2013-05-24T20:55:01.767",
"references": [
{
"source": "cve@mitre.org",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CERTFR-2019-AVI-615
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SPPA-T3000 MS3000 Migration Server | ||
| Siemens | N/A | SiNVR 3 Central Control Server (CCS) | ||
| Siemens | N/A | SIMATIC S7-1200 CPU | ||
| Siemens | N/A | RUGGEDCOM ROS RSG9xx R/C | ||
| Siemens | N/A | RUGGEDCOM ROS RMC8388 | ||
| Siemens | N/A | EN100 Ethernet module Modbus TCP | ||
| Siemens | N/A | SIMATIC WinCC OA | ||
| Siemens | N/A | SIMATIC CP 1626 | ||
| Siemens | N/A | SCALANCE W700 versions antérieures à V6.4 | ||
| Siemens | N/A | SIMATIC NET PC | ||
| Siemens | N/A | SIMATIC WinCC Runtime Professional | ||
| Siemens | N/A | EN100 Ethernet module IEC 61850 versions antérieures à V4.37 | ||
| Siemens | N/A | SPPA-T3000 Application Server versions antérieures à Service Pack R8.2 SP1 | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced | ||
| Siemens | N/A | RUGGEDCOM ROS RSL910 | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) versions antérieures à V16 | ||
| Siemens | N/A | Famille de commutateurs SCALANCE X-200IRT et les variantes SIPLUSNET versions antérieures à V5.4.2 | ||
| Siemens | N/A | SIMATIC S7-200 SMART CPU | ||
| Siemens | N/A | SIMATIC WinCC OA versions antérieures à 3.16 patch version 13 | ||
| Siemens | N/A | SiNVR 3 Video Server | ||
| Siemens | N/A | EN100 Ethernet module DNP3 | ||
| Siemens | N/A | SCALANCE W1700 versions antérieures à V1.1 | ||
| Siemens | N/A | RUGGEDCOM ROS RSG2488 | ||
| Siemens | N/A | EN100 Ethernet module PROFINET IO | ||
| Siemens | N/A | EN100 Ethernet module IEC104 | ||
| Siemens | N/A | RUGGEDCOM ROS RSG920P | ||
| Siemens | N/A | TIM 1531 IRC | ||
| Siemens | N/A | XHQ versions antérieures à V6.0.0.2 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) versions antérieures à V16 | ||
| Siemens | N/A | RUGGEDCOM ROS RST2228 | ||
| Siemens | N/A | SIMATIC HMI Panel | ||
| Siemens | N/A | Famille de commutateurs SCALANCE X-200 et les variantes SIPLUSNET versions antérieures à V5.2.4 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SPPA-T3000 MS3000 Migration Server",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiNVR 3 Central Control Server (CCS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1200 CPU",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RSG9xx R/C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RMC8388",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module Modbus TCP",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1626",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W700 versions ant\u00e9rieures \u00e0 V6.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Professional",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module IEC 61850 versions ant\u00e9rieures \u00e0 V4.37",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SPPA-T3000 Application Server versions ant\u00e9rieures \u00e0 Service Pack R8.2 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RSL910",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) versions ant\u00e9rieures \u00e0 V16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Famille de commutateurs SCALANCE X-200IRT et les variantes SIPLUSNET versions ant\u00e9rieures \u00e0 V5.4.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-200 SMART CPU",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA versions ant\u00e9rieures \u00e0 3.16 patch version 13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiNVR 3 Video Server",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module DNP3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1700 versions ant\u00e9rieures \u00e0 V1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RSG2488",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module PROFINET IO",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module IEC104",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RSG920P",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 1531 IRC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "XHQ versions ant\u00e9rieures \u00e0 V6.0.0.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) versions ant\u00e9rieures \u00e0 V16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RST2228",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Panel",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Famille de commutateurs SCALANCE X-200 et les variantes SIPLUSNET versions ant\u00e9rieures \u00e0 V5.2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-13944",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13944"
},
{
"name": "CVE-2019-18339",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18339"
},
{
"name": "CVE-2019-18341",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18341"
},
{
"name": "CVE-2019-18332",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18332"
},
{
"name": "CVE-2019-18335",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18335"
},
{
"name": "CVE-2019-18338",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18338"
},
{
"name": "CVE-2018-14526",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-14526"
},
{
"name": "CVE-2019-18319",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18319"
},
{
"name": "CVE-2019-18331",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18331"
},
{
"name": "CVE-2019-18312",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18312"
},
{
"name": "CVE-2019-18320",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18320"
},
{
"name": "CVE-2019-18322",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18322"
},
{
"name": "CVE-2019-18283",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18283"
},
{
"name": "CVE-2019-18303",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18303"
},
{
"name": "CVE-2019-18302",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18302"
},
{
"name": "CVE-2019-18311",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18311"
},
{
"name": "CVE-2019-18290",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18290"
},
{
"name": "CVE-2019-18292",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18292"
},
{
"name": "CVE-2019-18309",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18309"
},
{
"name": "CVE-2019-18291",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18291"
},
{
"name": "CVE-2019-18304",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18304"
},
{
"name": "CVE-2019-18326",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18326"
},
{
"name": "CVE-2019-18305",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18305"
},
{
"name": "CVE-2019-18318",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18318"
},
{
"name": "CVE-2013-3634",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-3634"
},
{
"name": "CVE-2019-18334",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18334"
},
{
"name": "CVE-2019-18299",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18299"
},
{
"name": "CVE-2019-13932",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13932"
},
{
"name": "CVE-2019-18316",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18316"
},
{
"name": "CVE-2019-18329",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18329"
},
{
"name": "CVE-2019-10929",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10929"
},
{
"name": "CVE-2019-13931",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13931"
},
{
"name": "CVE-2019-18333",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18333"
},
{
"name": "CVE-2019-18300",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18300"
},
{
"name": "CVE-2019-18301",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18301"
},
{
"name": "CVE-2019-18328",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18328"
},
{
"name": "CVE-2019-18321",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18321"
},
{
"name": "CVE-2019-13947",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13947"
},
{
"name": "CVE-2019-18317",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18317"
},
{
"name": "CVE-2019-18294",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18294"
},
{
"name": "CVE-2019-13943",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13943"
},
{
"name": "CVE-2019-18330",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18330"
},
{
"name": "CVE-2019-18314",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18314"
},
{
"name": "CVE-2019-18307",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18307"
},
{
"name": "CVE-2019-13945",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13945"
},
{
"name": "CVE-2019-18308",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18308"
},
{
"name": "CVE-2013-3633",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-3633"
},
{
"name": "CVE-2019-18306",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18306"
},
{
"name": "CVE-2019-18340",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18340"
},
{
"name": "CVE-2019-18342",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18342"
},
{
"name": "CVE-2019-18325",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18325"
},
{
"name": "CVE-2018-4832",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-4832"
},
{
"name": "CVE-2019-18310",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18310"
},
{
"name": "CVE-2019-13103",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13103"
},
{
"name": "CVE-2019-13930",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13930"
},
{
"name": "CVE-2019-18337",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18337"
},
{
"name": "CVE-2019-18323",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18323"
},
{
"name": "CVE-2019-18327",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18327"
},
{
"name": "CVE-2018-18440",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-18440"
},
{
"name": "CVE-2019-18315",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18315"
},
{
"name": "CVE-2019-18298",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18298"
},
{
"name": "CVE-2019-13942",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13942"
},
{
"name": "CVE-2019-18313",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18313"
},
{
"name": "CVE-2019-18324",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18324"
}
],
"initial_release_date": "2019-12-10T00:00:00",
"last_revision_date": "2019-12-10T00:00:00",
"links": [],
"reference": "CERTFR-2019-AVI-615",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-12-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-451445 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-418979 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-170686 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-344983 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344983.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-761617 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-618620 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-618620.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-525454 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-525454.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-686531 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-273799 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
}
]
}
CERTA-2013-AVI-327
Vulnerability from certfr_avis
De multiples vulnérabilités ont été corrigées dans le système SCADA Siemens Scalance X200 IRT. Elles permettent à un attaquant de provoquer un contournement de la politique de sécurité et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SCALANCE X204IRT versions antérieures à 5.1.0 | ||
| Siemens | N/A | SCALANCE X202-2P IRT versions antérieures à 5.1.0 | ||
| Siemens | N/A | SCALANCE X201-3P IRT versions antérieures à 5.1.0 | ||
| Siemens | N/A | SCALANCE X201-3P IRT PRO versions antérieures à 5.1.0 | ||
| Siemens | N/A | SCALANCE X204IRT PRO versions antérieures à 5.1.0 | ||
| Siemens | N/A | SCALANCE X202-2P IRT PRO versions antérieures à 5.1.0 | ||
| Siemens | N/A | SCALANCE XF204IRT versions antérieures à 5.1.0 | ||
| Siemens | N/A | SCALANCE X200-4P IRT versions antérieures à 5.1.0 | ||
| Siemens | N/A | SCALANCE X202-2IRT versions antérieures à 5.1.0 |
| Title | Publication Time | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SCALANCE X204IRT versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X202-2P IRT versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X201-3P IRT versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X201-3P IRT PRO versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X204IRT PRO versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X202-2P IRT PRO versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204IRT versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X200-4P IRT versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X202-2IRT versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2013-3634",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-3634"
},
{
"name": "CVE-2013-3633",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-3633"
}
],
"initial_release_date": "2013-05-27T00:00:00",
"last_revision_date": "2013-05-27T00:00:00",
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 SCADA Siemens SSA-170686 du 24 mai 2013",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-170686.pdf"
}
],
"reference": "CERTA-2013-AVI-327",
"revisions": [
{
"description": "version initiale.",
"revision_date": "2013-05-27T00:00:00.000000"
}
],
"risks": [
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 corrig\u00e9es dans le syst\u00e8me SCADA\n\u003cspan class=\"textit\"\u003eSiemens Scalance X200 IRT\u003c/span\u003e. Elles permettent\n\u00e0 un attaquant de provoquer un contournement de la politique de s\u00e9curit\u00e9\net une \u00e9l\u00e9vation de privil\u00e8ges.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans le syst\u00e8me SCADA Siemens Scalance X200 IRT",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SCADA Siemens SSA-170686 du 24 mai 2013",
"url": null
}
]
}
ghsa-c9w7-6876-4mvr
Vulnerability from github
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.
{
"affected": [],
"aliases": [
"CVE-2013-3634"
],
"database_specific": {
"cwe_ids": [
"CWE-20"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2013-05-24T20:55:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.",
"id": "GHSA-c9w7-6876-4mvr",
"modified": "2022-05-13T01:30:17Z",
"published": "2022-05-13T01:30:17Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2013-3634"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
gsd-2013-3634
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2013-3634",
"description": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.",
"id": "GSD-2013-3634"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2013-3634"
],
"details": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.",
"id": "GSD-2013-3634",
"modified": "2023-12-13T01:22:22.431522Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3634",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x200irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2p_irt:-:-:pro:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:-:pro:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt:-:-:pro:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3634"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf",
"refsource": "CONFIRM",
"tags": [],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
}
},
"lastModifiedDate": "2019-12-12T20:15Z",
"publishedDate": "2013-05-24T20:55Z"
}
}
}
icsa-13-169-01
Vulnerability from csaf_cisa
Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-13-169-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2013/icsa-13-169-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-13-169-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-13-169-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Siemens Scalance X200 IRT Multiple Vulnerabilities",
"tracking": {
"current_release_date": "2025-06-06T16:06:44.607249Z",
"generator": {
"date": "2025-06-06T16:06:44.607160Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-13-169-01",
"initial_release_date": "2013-03-21T06:00:00.000000Z",
"revision_history": [
{
"date": "2013-03-21T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2025-06-06T16:06:44.607249Z",
"legacy_version": "CSAF Conversion",
"number": "2",
"summary": "Advisory converted into a CSAF"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.1.0",
"product": {
"name": "Siemens SCALANCE X204IRT: \u003cV5.1.0",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.1.0",
"product": {
"name": "Siemens SCALANCE X204IRT PRO: \u003cV5.1.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT PRO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.1.0",
"product": {
"name": "Siemens SCALANCE X202-2IRT: \u003cV5.1.0",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2IRT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.1.0",
"product": {
"name": "Siemens SCALANCE X202-2P IRT: \u003cV5.1.0",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2P IRT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.1.0",
"product": {
"name": "Siemens SCALANCE X202-2P IRT PRO: \u003cV5.1.0",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2P IRT PRO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.1.0",
"product": {
"name": "Siemens SCALANCE X201-3P IRT: \u003cV5.1.0",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "SCALANCE X201-3P IRT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.1.0",
"product": {
"name": "Siemens SCALANCE X201-3P IRT PRO: \u003cV5.1.0",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "SCALANCE X201-3P IRT PRO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.1.0",
"product": {
"name": "Siemens SCALANCE X200-4P IRT: \u003cV5.1.0",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "SCALANCE X200-4P IRT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.1.0",
"product": {
"name": "Siemens SCALANCE XF204IRT: \u003cV5.1.0",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "SCALANCE XF204IRT"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2013-3633",
"cwe": {
"id": "CWE-602",
"name": "Client-Side Enforcement of Server-Side Security"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The user privileges for the web interface are only enforced on client side and not properly verified on server side. Therefore, an attacker is able to execute privileged commands using an unprivileged account.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens has produced a software update, Scalance X-200IRT V5.1.0 that resolves these vulnerabilities. Siemens recommends that asset owners and operators contact Siemens customer support to acquire the update.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
},
{
"category": "mitigation",
"details": "Siemens update information is located here: (http://support.automation.siemens.com/WW/view/en/73470284)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
],
"url": "http://support.automation.siemens.com/WW/view/en/73470284"
},
{
"category": "mitigation",
"details": "Siemens security advisory is located here: (https://cert-portal.siemens.com/productcert/html/ssa-170686.html)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-170686.html"
},
{
"category": "mitigation",
"details": "Siemens suggests that if it is not possible to install the update, a workaround for CVE-2013-3634 is either to disable SNMP or to completely disable any read-write access.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 8.0,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
}
]
},
{
"cve": "CVE-2013-3634",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions \u003c V5.0.0 for CVE-2013-3633 and versions \u003c V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens has produced a software update, Scalance X-200IRT V5.1.0 that resolves these vulnerabilities. Siemens recommends that asset owners and operators contact Siemens customer support to acquire the update.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
},
{
"category": "mitigation",
"details": "Siemens update information is located here: (http://support.automation.siemens.com/WW/view/en/73470284)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
],
"url": "http://support.automation.siemens.com/WW/view/en/73470284"
},
{
"category": "mitigation",
"details": "Siemens security advisory is located here: (https://cert-portal.siemens.com/productcert/html/ssa-170686.html)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-170686.html"
},
{
"category": "mitigation",
"details": "Siemens suggests that if it is not possible to install the update, a workaround for CVE-2013-3634 is either to disable SNMP or to completely disable any read-write access.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
}
]
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.