GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CNVD-2018-18137

Vulnerability from cnvd - Published: 2018-09-10
VLAI
Title
多款Medtronic产品信息泄露漏洞(CNVD-2018-18137)
Description
Medtronic MMT-508 MiniMed insulin pump等都是美国Medtronic公司的不同型号的胰岛素泵。 多款Medtronic产品中存在信息泄露漏洞,该漏洞源于pump和无线配件之间通信以明文的形式进行传递。攻击者可利用该漏洞截获所传递的信息并提取敏感信息(例如:设备序列号)。
Severity
Formal description

厂商尚未提供漏洞修复方案,请关注厂商主页更新: http://www.medtronic.com/us-en/index.html

Reference
https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-02
Impacted products
Name
['Medtronic MMT - 551 / MMT - 751 MiniMed 530G', 'Medtronic MMT - 523K / MMT - 723K Paradigm Revel', 'Medtronic MMT - 523 / MMT - 723 Paradigm Revel', 'Medtronic MMT - 522 / MMT - 722 Paradigm REAL-TIME', 'Medtronic MMT - 508 MiniMed insulin pump']
Show details on source website

{
  "cves": {
    "cve": {
      "cveNumber": "CVE-2018-10634"
    }
  },
  "description": "Medtronic MMT-508 MiniMed insulin pump\u7b49\u90fd\u662f\u7f8e\u56fdMedtronic\u516c\u53f8\u7684\u4e0d\u540c\u578b\u53f7\u7684\u80f0\u5c9b\u7d20\u6cf5\u3002\r\n\r\n\u591a\u6b3eMedtronic\u4ea7\u54c1\u4e2d\u5b58\u5728\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8epump\u548c\u65e0\u7ebf\u914d\u4ef6\u4e4b\u95f4\u901a\u4fe1\u4ee5\u660e\u6587\u7684\u5f62\u5f0f\u8fdb\u884c\u4f20\u9012\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u622a\u83b7\u6240\u4f20\u9012\u7684\u4fe1\u606f\u5e76\u63d0\u53d6\u654f\u611f\u4fe1\u606f\uff08\u4f8b\u5982\uff1a\u8bbe\u5907\u5e8f\u5217\u53f7\uff09\u3002",
  "discovererName": "Billy Rios, Jesse Young, and Jonathan Butts of Whitescope LLC",
  "formalWay": "\u5382\u5546\u5c1a\u672a\u63d0\u4f9b\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\uff0c\u8bf7\u5173\u6ce8\u5382\u5546\u4e3b\u9875\u66f4\u65b0\uff1a\r\nhttp://www.medtronic.com/us-en/index.html",
  "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
  "number": "CNVD-2018-18137",
  "openTime": "2018-09-10",
  "products": {
    "product": [
      "Medtronic MMT - 551 / MMT - 751 MiniMed 530G",
      "Medtronic MMT - 523K / MMT - 723K Paradigm Revel",
      "Medtronic MMT - 523 / MMT - 723 Paradigm Revel",
      "Medtronic MMT - 522 / MMT - 722 Paradigm REAL-TIME",
      "Medtronic MMT - 508 MiniMed insulin pump"
    ]
  },
  "referenceLink": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-02",
  "serverity": "\u4e2d",
  "submitTime": "2018-08-14",
  "title": "\u591a\u6b3eMedtronic\u4ea7\u54c1\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e\uff08CNVD-2018-18137\uff09"
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…