Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CERTFR-2025-AVI-0497
Vulnerability from certfr_avis - Published: - Updated:
Une vulnérabilité a été découverte dans les processeurs Intel. Elle permet à un attaquant de provoquer un déni de service.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
Impacted products
References
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "les processeurs Intel sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Intel",
"scada": false
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2025-2884",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-2884"
}
],
"links": [],
"reference": "CERTFR-2025-AVI-0497",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-06-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service"
}
],
"summary": "Une vuln\u00e9rabilit\u00e9 a \u00e9t\u00e9 d\u00e9couverte dans les processeurs Intel. Elle permet \u00e0 un attaquant de provoquer un d\u00e9ni de service.",
"title": "Vuln\u00e9rabilit\u00e9 dans les processeurs Intel",
"vendor_advisories": [
{
"published_at": "2025-06-10",
"title": "Bulletin de s\u00e9curit\u00e9 Intel INTEL-SA-01209",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html"
}
]
}
CVE-2025-2884 (GCVE-0-2025-2884)
Vulnerability from cvelistv5 – Published: 2025-06-10 17:29 – Updated: 2026-04-14 08:58
VLAI
EPSS
Title
Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation
Summary
TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0
Severity
6.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-125 Out-of-bounds Read
- CWE-125 - Out-of-bounds Read
Assigner
References
8 references
Impacted products
25 products
| Vendor | Product | Version | |
|---|---|---|---|
| Trusted Computing Group | TPM2.0 |
Affected:
0 , < 1.83
(custom)
|
|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC BX-32A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC BX-39A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC BX-56A |
Affected:
0 , < V32.01.09
(custom)
|
|
| Siemens | SIMATIC IPC BX-59A |
Affected:
0 , < V32.01.09
(custom)
|
|
| Siemens | SIMATIC IPC MD-57A |
Affected:
0 , < V30.01.10
(custom)
|
|
| Siemens | SIMATIC IPC PX-32A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A PRO |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC RW-528A |
Affected:
0 , < V34.01.02
(custom)
|
|
| Siemens | SIMATIC IPC RW-548A |
Affected:
0 , < V34.01.02
(custom)
|
|
| Siemens | SIMATIC IPC227E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC277E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.20
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.20
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.20
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.20
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-06-10T19:02:29.811Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html"
},
{
"url": "https://www.kb.cert.org/vuls/id/282450"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-2884",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-13T01:41:10.489446Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-13T01:46:13.802Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-32A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-56A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V32.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-59A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V32.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC MD-57A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V30.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-32A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC RW-528A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V34.01.02",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC RW-548A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V34.01.02",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T08:58:06.200Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "TPM2.0",
"vendor": "Trusted Computing Group",
"versions": [
{
"lessThan": "1.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TCG TPM2.0 Reference implementation\u0027s CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key\u0027s algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0"
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2884",
"selections": [
{
"name": "Exploitation",
"namespace": "ssvc",
"values": [
"none"
],
"version": "1.0.0"
},
{
"name": "Automatable",
"namespace": "ssvc",
"values": [
"no"
],
"version": "2.0.0"
},
{
"name": "Technical Impact",
"namespace": "ssvc",
"values": [
"partial"
],
"version": "1.0.0"
},
{
"name": "Mission \u0026 Well-being",
"namespace": "ssvc",
"values": [
"medium"
],
"version": "1.0.0"
}
],
"timestamp": "2025-06-13T17:22:30.584Z"
},
"type": "ssvcV1_0_1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-125 Out-of-bounds Read",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-13T18:22:21.856Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://trustedcomputinggroup.org/about/security/"
},
{
"name": "TPM2.0 Errata",
"url": "https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf"
},
{
"name": "Vendor Advisory",
"url": "https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf"
},
{
"name": "Vendor Patch",
"url": "https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1"
},
{
"name": "Related CVE",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-49133"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation",
"x_generator": {
"engine": "VINCE 3.0.20",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2025-2884"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2025-2884",
"datePublished": "2025-06-10T17:29:19.463Z",
"dateReserved": "2025-03-27T21:01:41.908Z",
"dateUpdated": "2026-04-14T08:58:06.200Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…