ICSA-21-047-01
Vulnerability from csaf_cisa
Published
2021-02-09 00:00
Modified
2025-05-06 06:00
Summary
Open Design Alliance Drawings SDK (Update A)

Notes

Summary
Siemens has released version V13.1.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (BMP, TIFF, CGM, TGA, PCT, HPG, PLT, RAS, PAR, ASM, DXF, DWG). If a user is tricked to opening of a malicious file with the affected products, this could lead to application crash, or potentially arbitrary code execution or data extraction on the target host system. Siemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products. Notes: - Previous versions of this advisory incorrectly listed the following vulnerabilities as being fixed in V13.1.0.1: CVE-2020-26991, CVE-2020-26998, CVE-2020-26999, CVE-2020-27001 and CVE-2020-27002. Those were fixed in V13.1.0.2 and are therefore addressed in advisory SSA-695540 [0] - The vulnerability CVE-2020-28383 was incorrectly listed in SSA-622830 [1] as being fixed in V13.1.0.0. This was fixed in V13.1.0.1 and therefore added here - The Open Design Alliance [2] recently disclosed an additional vulnerability (CVE-2021-31784) which is also covered in this advisory [0] https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf [1] https://cert-portal.siemens.com/productcert/pdf/ssa-695540.pdf [2] https://www.opendesign.com/security-advisories
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.



{
  "document": {
    "acknowledgments": [
      {
        "organization": "Siemens ProductCERT",
        "summary": "reporting these vulnerabilities to CISA."
      },
      {
        "organization": "Trend Micro Zero Day Initiative",
        "summary": "coordinated disclosure"
      },
      {
        "organization": "Open Design Alliance",
        "summary": "coordination efforts"
      },
      {
        "organization": "Cybersecurity and Infrastructure Security Agency (CISA)",
        "summary": "coordination efforts"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "Siemens has released version V13.1.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (BMP, TIFF, CGM, TGA, PCT, HPG, PLT, RAS, PAR, ASM, DXF, DWG). If a user is tricked to opening of a malicious file with the affected products, this could lead to application crash, or potentially arbitrary code execution or data extraction on the target host system.\n\nSiemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products.\n\nNotes:\n\n-   Previous versions of this advisory incorrectly listed the following vulnerabilities as being fixed in V13.1.0.1: CVE-2020-26991, CVE-2020-26998, CVE-2020-26999, CVE-2020-27001 and CVE-2020-27002. Those were fixed in V13.1.0.2 and are therefore addressed in advisory SSA-695540 [0]\n\n-   The vulnerability CVE-2020-28383 was incorrectly listed in SSA-622830 [1] as being fixed in V13.1.0.0. This was fixed in V13.1.0.1 and therefore added here\n\n-   The Open Design Alliance [2] recently disclosed an additional vulnerability (CVE-2021-31784) which is also covered in this advisory\n\n[0] https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf\n\n[1] https://cert-portal.siemens.com/productcert/pdf/ssa-695540.pdf\n\n[2] https://www.opendesign.com/security-advisories",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "other",
        "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
        "title": "Advisory Conversion Disclaimer"
      },
      {
        "category": "other",
        "text": "Multiple",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Germany",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      }
    ],
    "publisher": {
      "category": "other",
      "contact_details": "central@cisa.dhs.gov",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-663999.json"
      },
      {
        "category": "self",
        "summary": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1 - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-663999.txt"
      },
      {
        "category": "self",
        "summary": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1 - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-21-047-01 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-047-01.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-21-047-01 - Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-047-01"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/topics/industrial-control-systems"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      }
    ],
    "title": "Open Design Alliance Drawings SDK (Update A)",
    "tracking": {
      "current_release_date": "2025-05-06T06:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-21-047-01",
      "initial_release_date": "2021-02-09T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2021-02-09T00:00:00.000000Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2021-05-17T00:00:00.000000Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Removed the vulnerabilities CVE-2020-26991, CVE-2020-26998, CVE-2020-26999, CVE-2020-27001, CVE-2020-27002, and added CVE-2020-28383, CVE-2021-31784 for the reasons described in the Summary"
        },
        {
          "date": "2025-05-06T06:00:00.000000Z",
          "legacy_version": "Revision",
          "number": "3",
          "summary": "Revision - Fixing typos"
        }
      ],
      "status": "final",
      "version": "3"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV13.1.0.1",
                "product": {
                  "name": "JT2Go",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "JT2Go"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV13.1.0.1",
                "product": {
                  "name": "Teamcenter Visualization",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter Visualization"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2020-26989",
      "cwe": {
        "id": "CWE-121",
        "name": "Stack-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-26989 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-26989 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-26989.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-26989"
    },
    {
      "cve": "CVE-2020-26990",
      "cwe": {
        "id": "CWE-843",
        "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing ASM files. A crafted ASM file could trigger a type confusion condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11897)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-26990 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-26990 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-26990.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-26990"
    },
    {
      "cve": "CVE-2020-27000",
      "cwe": {
        "id": "CWE-119",
        "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing BMP files. This can result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12018)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27000 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27000 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27000.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-27000"
    },
    {
      "cve": "CVE-2020-27003",
      "cwe": {
        "id": "CWE-822",
        "name": "Untrusted Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing TIFF files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12158)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27003 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27003 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27003.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-27003"
    },
    {
      "cve": "CVE-2020-27004",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of CGM files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12163)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27004 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27004 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27004.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-27004"
    },
    {
      "cve": "CVE-2020-27005",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of TGA files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12178)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27005 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27005 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27005.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-27005"
    },
    {
      "cve": "CVE-2020-27006",
      "cwe": {
        "id": "CWE-119",
        "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of PCT files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12182)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27006 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27006 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27006.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-27006"
    },
    {
      "cve": "CVE-2020-27007",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of HPG files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12207)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27007 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27007 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27007.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-27007"
    },
    {
      "cve": "CVE-2020-27008",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of PLT files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12209)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27008 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27008 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27008.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-27008"
    },
    {
      "cve": "CVE-2020-28383",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-28383 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-28383 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28383.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-28383"
    },
    {
      "cve": "CVE-2020-28394",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of RAS files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12283)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-28394 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-28394 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28394.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2020-28394"
    },
    {
      "cve": "CVE-2021-25173",
      "cwe": {
        "id": "CWE-789",
        "name": "Memory Allocation with Excessive Size Value"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory allocation with excessive size vulnerability exists when reading malformed DGN files, which could allow attackers to cause a crash, potentially enabling denial of service (crash, exit, or restart). (ZDI-CAN-12019)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25173 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25173 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25173.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2021-25173"
    },
    {
      "cve": "CVE-2021-25174",
      "cwe": {
        "id": "CWE-789",
        "name": "Memory Allocation with Excessive Size Value"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It could allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart). (ZDI-CAN-12026)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25174 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25174 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25174.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2021-25174"
    },
    {
      "cve": "CVE-2021-25175",
      "cwe": {
        "id": "CWE-822",
        "name": "Untrusted Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Conversion issue exists when rendering malformed .DXF and .DWG files. This could allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). (ZDI-CAN-11912, ZDI-CAN-11993, ZDI-CAN-11988)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25175 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25175 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25175.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2021-25175"
    },
    {
      "cve": "CVE-2021-25176",
      "cwe": {
        "id": "CWE-822",
        "name": "Untrusted Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This could allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). (ZDI-CAN-11913, ZDI-CAN-11989)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25176 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25176 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25176.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2021-25176"
    },
    {
      "cve": "CVE-2021-25177",
      "cwe": {
        "id": "CWE-843",
        "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. (ZDI-CAN-11927)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25177 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25177 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25177.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2021-25177"
    },
    {
      "cve": "CVE-2021-25178",
      "cwe": {
        "id": "CWE-121",
        "name": "Stack-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. (ZDI-CAN-11901, ZDI-CAN-12165, ZDI-CAN-12166)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25178 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25178 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25178.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2021-25178"
    },
    {
      "cve": "CVE-2021-31784",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An out-of-bounds write vulnerability exists in the file-reading procedure in Open Design Alliance Drawings SDK before 2021.6.\n\nThis could allow an attacker to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. (ZDI-CAN-11915)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-31784 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-31784 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31784.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2021-31784"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…