CVE-2026-53479 (GCVE-0-2026-53479)

Vulnerability from cvelistv5 – Published: 2026-07-07 13:07 – Updated: 2026-07-08 13:41
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to protection mechanism bypass. This is a Critical vulnerability as it allows an attacker to invoke arbitrary command execution with root privileges; so Dell recommends customers to upgrade at the earliest opportunity.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Domain Affected: 0 , < 8.8.0.0 or later (semver)
Affected: 0 , < 8.6.1.20 or later (semver)
Affected: 0 , < 8.3.1.40 or later (semver)
Affected: 0 , < 7.13.1.80 or later (semver)
Create a notification for this product.
Date Public
2026-07-02 06:30
Credits
Dell would like to thank Ahmed Y. Elmogy for reporting these issues.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-53479",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-08T03:56:33.302107Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-08T13:41:13.329Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Domain",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.8.0.0 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "8.6.1.20 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "8.3.1.40 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "7.13.1.80 or later",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "other",
          "value": "Dell would like to thank Ahmed Y. Elmogy for reporting these issues."
        }
      ],
      "datePublic": "2026-07-02T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell\u0026nbsp;PowerProtect\u0026nbsp;Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70\u0026nbsp;contain\u202fan improper neutralization of special elements used in an OS\u0026nbsp;command (\u0027OS\u0026nbsp;command Injection\u0027) vulnerability.\u0026nbsp;A\u0026nbsp;remote\u0026nbsp;high\u0026nbsp;privileged attacker could potentially exploit this vulnerability, leading to\u0026nbsp;protection mechanism bypass.\u0026nbsp;This is a Critical vulnerability as it allows an attacker\u0026nbsp;to\u0026nbsp;invoke arbitrary command execution with root privileges;\u0026nbsp;so\u0026nbsp;Dell recommends customers to upgrade at the earliest opportunity."
            }
          ],
          "value": "Dell\u00a0PowerProtect\u00a0Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70\u00a0contain\u202fan improper neutralization of special elements used in an OS\u00a0command (\u0027OS\u00a0command Injection\u0027) vulnerability.\u00a0A\u00a0remote\u00a0high\u00a0privileged attacker could potentially exploit this vulnerability, leading to\u00a0protection mechanism bypass.\u00a0This is a Critical vulnerability as it allows an attacker\u00a0to\u00a0invoke arbitrary command execution with root privileges;\u00a0so\u00a0Dell recommends customers to upgrade at the earliest opportunity."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-07T13:07:26.591Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2026-53479",
    "datePublished": "2026-07-07T13:07:26.591Z",
    "dateReserved": "2026-06-09T17:04:35.250Z",
    "dateUpdated": "2026-07-08T13:41:13.329Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-53479",
      "date": "2026-07-09",
      "epss": "0.01196",
      "percentile": "0.64405"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-53479\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2026-07-07T14:16:32.410\",\"lastModified\":\"2026-07-08T19:57:25.183\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell\u00a0PowerProtect\u00a0Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70\u00a0contain\u202fan improper neutralization of special elements used in an OS\u00a0command (\u0027OS\u00a0command Injection\u0027) vulnerability.\u00a0A\u00a0remote\u00a0high\u00a0privileged attacker could potentially exploit this vulnerability, leading to\u00a0protection mechanism bypass.\u00a0This is a Critical vulnerability as it allows an attacker\u00a0to\u00a0invoke arbitrary command execution with root privileges;\u00a0so\u00a0Dell recommends customers to upgrade at the earliest opportunity.\"}],\"affected\":[{\"source\":\"security_alert@emc.com\",\"affectedData\":[{\"vendor\":\"Dell\",\"product\":\"PowerProtect Data Domain\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.8.0.0 or later\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"0\",\"lessThan\":\"8.6.1.20 or later\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"0\",\"lessThan\":\"8.3.1.40 or later\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"0\",\"lessThan\":\"7.13.1.80 or later\",\"versionType\":\"semver\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-07-08T03:56:33.302107Z\",\"id\":\"CVE-2026-53479\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.7.1.0\",\"versionEndExcluding\":\"7.13.1.80\",\"matchCriteriaId\":\"064F56BA-B974-4133-9DFA-B13D503766AC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.14.0.0\",\"versionEndExcluding\":\"8.3.1.40\",\"matchCriteriaId\":\"EB4BB568-B169-4202-94E0-8D808419241B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.4.0.0\",\"versionEndExcluding\":\"8.6.1.20\",\"matchCriteriaId\":\"BA61361F-FED8-4936-A9F6-FFA35BE413F8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.7.0.0\",\"versionEndExcluding\":\"8.8.0.0\",\"matchCriteriaId\":\"4BA45B0F-6A67-476D-9101-0DDC91B77D51\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"other\", \"value\": \"Dell would like to thank Ahmed Y. Elmogy for reporting these issues.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerProtect Data Domain\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.8.0.0 or later\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.6.1.20 or later\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.3.1.40 or later\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"7.13.1.80 or later\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-07-02T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.2\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell\\u00a0PowerProtect\\u00a0Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70\\u00a0contain\\u202fan improper neutralization of special elements used in an OS\\u00a0command (\u0027OS\\u00a0command Injection\u0027) vulnerability.\\u00a0A\\u00a0remote\\u00a0high\\u00a0privileged attacker could potentially exploit this vulnerability, leading to\\u00a0protection mechanism bypass.\\u00a0This is a Critical vulnerability as it allows an attacker\\u00a0to\\u00a0invoke arbitrary command execution with root privileges;\\u00a0so\\u00a0Dell recommends customers to upgrade at the earliest opportunity.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell\u0026nbsp;PowerProtect\u0026nbsp;Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70\u0026nbsp;contain\\u202fan improper neutralization of special elements used in an OS\u0026nbsp;command (\u0027OS\u0026nbsp;command Injection\u0027) vulnerability.\u0026nbsp;A\u0026nbsp;remote\u0026nbsp;high\u0026nbsp;privileged attacker could potentially exploit this vulnerability, leading to\u0026nbsp;protection mechanism bypass.\u0026nbsp;This is a Critical vulnerability as it allows an attacker\u0026nbsp;to\u0026nbsp;invoke arbitrary command execution with root privileges;\u0026nbsp;so\u0026nbsp;Dell recommends customers to upgrade at the earliest opportunity.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2026-07-07T13:07:26.591Z\"}}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-53479\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-07-08T03:56:33.302107Z\"}}}], \"providerMetadata\": {\"shortName\": \"CISA-ADP\", \"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"dateUpdated\": \"2026-07-08T13:41:10.322Z\"}}]}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-53479\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-07-07T13:07:26.591Z\", \"dateReserved\": \"2026-06-09T17:04:35.250Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2026-07-07T13:07:26.591Z\", \"assignerShortName\": \"dell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…