GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2026-36174 (GCVE-0-2026-36174)

Vulnerability from cvelistv5 – Published: 2026-06-04 00:00 – Updated: 2026-07-05 16:16
VLAI
Summary
GNCC GP5 v7.1.76 was discovered to store sensitive wireless network information in plaintext during routine operations to the serial console. This issue allows physically-proximate attackers to obtain sensitive information, including network credentials, via monitoring the serial UART interface.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 13:59 UTC
CWE
  • n/a
  • CWE-256 - Plaintext Storage of a Password
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "NONE",
              "baseScore": 4.6,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2026-36174",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T13:59:07.714870Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-256",
                "description": "CWE-256 Plaintext Storage of a Password",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T14:00:45.789Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "GNCC GP5 v7.1.76 was discovered to store sensitive wireless network information in plaintext during routine operations to the serial console. This issue allows physically-proximate attackers to obtain sensitive information, including network credentials, via monitoring the serial UART interface."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-05T16:16:48.001Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2026-36174",
    "datePublished": "2026-06-04T00:00:00.000Z",
    "dateReserved": "2026-04-06T00:00:00.000Z",
    "dateUpdated": "2026-07-05T16:16:48.001Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-36174",
      "date": "2026-09-15",
      "epss": "0.0014",
      "percentile": "0.03682"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-36174\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2026-06-04T15:16:51.093\",\"lastModified\":\"2026-07-22T20:10:00.127\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"GNCC GP5 v7.1.76 was discovered to store sensitive wireless network information in plaintext during routine operations to the serial console. This issue allows physically-proximate attackers to obtain sensitive information, including network credentials, via monitoring the serial UART interface.\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 que GNCC GP5 v7.1.76 almacenaba informaci\u00f3n sensible de la red inal\u00e1mbrica en texto plano durante operaciones rutinarias en la consola serie. Este problema permite a atacantes f\u00edsicamente pr\u00f3ximos obtener informaci\u00f3n sensible, incluyendo credenciales de red, mediante la monitorizaci\u00f3n de la interfaz UART serie.\"}],\"affected\":[{\"source\":\"cve@mitre.org\",\"affectedData\":[{\"vendor\":\"n/a\",\"product\":\"n/a\",\"versions\":[{\"version\":\"n/a\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.6,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.9,\"impactScore\":3.6}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-06-08T13:59:07.714870Z\",\"id\":\"CVE-2026-36174\",\"options\":[{\"exploitation\":\"poc\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-256\"}]}],\"references\":[{\"url\":\"https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.6, \"attackVector\": \"PHYSICAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-36174\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-06-08T13:59:07.714870Z\"}}}], \"references\": [{\"url\": \"https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md\", \"tags\": [\"exploit\"]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-256\", \"description\": \"CWE-256 Plaintext Storage of a Password\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-06-08T13:59:36.959Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"http://gncc.com\"}, {\"url\": \"http://gp5.com\"}, {\"url\": \"https://github.com/BadChemical/IoT-Vulnerability-Research-Public/blob/main/GNCC-GP5-T23/README.md\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"GNCC GP5 v7.1.76 was discovered to store sensitive wireless network information in plaintext during routine operations to the serial console. This issue allows physically-proximate attackers to obtain sensitive information, including network credentials, via monitoring the serial UART interface.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2026-06-04T14:13:20.490Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-36174\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-06-08T14:00:45.789Z\", \"dateReserved\": \"2026-04-06T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2026-06-04T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…