CVE-2025-55069 (GCVE-0-2025-55069)
Vulnerability from cvelistv5
Published
2025-09-23 22:15
Modified
2025-09-24 14:07
CWE
  • CWE-337 - Predictable Seed in Pseudo-Random Number Generator
Summary
A predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the generated private keys.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-55069",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-24T14:06:23.215875Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-24T14:07:59.115Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CLICK PLUS C0-0x CPU firmware",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "v3.71",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CLICK PLUS C0-1x CPU firmware",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "v3.71",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CLICK PLUS C2-x CPU firmware",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "v3.71",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Luca Borzacchiello and Diego Zaffaroni of Nozomi Networks reported these vulnerabilities to Automation Direct."
        }
      ],
      "datePublic": "2025-09-23T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the generated private keys.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "A predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the generated private keys."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-337",
              "description": "CWE-337 Predictable Seed in Pseudo-Random Number Generator",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-23T22:15:46.833Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-266-01"
        },
        {
          "url": "https://www.automationdirect.com/support/software-downloads"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAutomationDirect recommends that users update CLICK PLUS and firmware to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.automationdirect.com/support/software-downloads\"\u003eV3.80.\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNetwork Isolation \u2013 Disconnect the CLICK PLUS PLC from external networks (e.g., the internet or corporate LAN) to reduce exposure.\u003c/li\u003e\u003cli\u003eSecure Communications \u2013 Use only trusted, dedicated internal networks or air-gapped systems for device communication.\u003c/li\u003e\u003cli\u003eAccess Control \u2013 Restrict both physical and logical access to authorized personnel only.\u003c/li\u003e\u003cli\u003eApplication Whitelisting \u2013 Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software.\u003c/li\u003e\u003cli\u003eEndpoint Protection \u2013 Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts.\u003c/li\u003e\u003cli\u003eLogging \u0026amp; Monitoring \u2013 Enable and regularly review system logs to detect suspicious or unauthorized activity.\u003c/li\u003e\u003cli\u003eBackup \u0026amp; Recovery \u2013 Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident.\u003c/li\u003e\u003cli\u003eOngoing Risk Assessment \u2013 Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "AutomationDirect recommends that users update CLICK PLUS and firmware to  V3.80. https://www.automationdirect.com/support/software-downloads \n\nIf the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed:\n\n  *  Network Isolation \u2013 Disconnect the CLICK PLUS PLC from external networks (e.g., the internet or corporate LAN) to reduce exposure.\n  *  Secure Communications \u2013 Use only trusted, dedicated internal networks or air-gapped systems for device communication.\n  *  Access Control \u2013 Restrict both physical and logical access to authorized personnel only.\n  *  Application Whitelisting \u2013 Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software.\n  *  Endpoint Protection \u2013 Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts.\n  *  Logging \u0026 Monitoring \u2013 Enable and regularly review system logs to detect suspicious or unauthorized activity.\n  *  Backup \u0026 Recovery \u2013 Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident.\n  *  Ongoing Risk Assessment \u2013 Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly."
        }
      ],
      "source": {
        "advisory": "ICSA-25-266-01",
        "discovery": "EXTERNAL"
      },
      "title": "AutomationDirect CLICK PLUS Predictable Seed in Pseudo-Random Number Generator",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-55069",
    "datePublished": "2025-09-23T22:15:46.833Z",
    "dateReserved": "2025-09-16T20:09:26.643Z",
    "dateUpdated": "2025-09-24T14:07:59.115Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-55069\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2025-09-23T23:15:30.717\",\"lastModified\":\"2025-09-24T18:11:24.520\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the generated private keys.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"PASSIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L\",\"baseScore\":8.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":5.5}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-337\"}]}],\"references\":[{\"url\":\"https://www.automationdirect.com/support/software-downloads\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-25-266-01\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-55069\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-24T14:06:23.215875Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-24T14:07:56.284Z\"}}], \"cna\": {\"title\": \"AutomationDirect CLICK PLUS Predictable Seed in Pseudo-Random Number Generator\", \"source\": {\"advisory\": \"ICSA-25-266-01\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Luca Borzacchiello and Diego Zaffaroni of Nozomi Networks reported these vulnerabilities to Automation Direct.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"PASSIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"AutomationDirect\", \"product\": \"CLICK PLUS C0-0x CPU firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"v3.71\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"AutomationDirect\", \"product\": \"CLICK PLUS C0-1x CPU firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"v3.71\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"AutomationDirect\", \"product\": \"CLICK PLUS C2-x CPU firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"v3.71\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"AutomationDirect recommends that users update CLICK PLUS and firmware to  V3.80. https://www.automationdirect.com/support/software-downloads \\n\\nIf the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed:\\n\\n  *  Network Isolation \\u2013 Disconnect the CLICK PLUS PLC from external networks (e.g., the internet or corporate LAN) to reduce exposure.\\n  *  Secure Communications \\u2013 Use only trusted, dedicated internal networks or air-gapped systems for device communication.\\n  *  Access Control \\u2013 Restrict both physical and logical access to authorized personnel only.\\n  *  Application Whitelisting \\u2013 Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software.\\n  *  Endpoint Protection \\u2013 Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts.\\n  *  Logging \u0026 Monitoring \\u2013 Enable and regularly review system logs to detect suspicious or unauthorized activity.\\n  *  Backup \u0026 Recovery \\u2013 Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident.\\n  *  Ongoing Risk Assessment \\u2013 Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eAutomationDirect recommends that users update CLICK PLUS and firmware to \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.automationdirect.com/support/software-downloads\\\"\u003eV3.80.\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNetwork Isolation \\u2013 Disconnect the CLICK PLUS PLC from external networks (e.g., the internet or corporate LAN) to reduce exposure.\u003c/li\u003e\u003cli\u003eSecure Communications \\u2013 Use only trusted, dedicated internal networks or air-gapped systems for device communication.\u003c/li\u003e\u003cli\u003eAccess Control \\u2013 Restrict both physical and logical access to authorized personnel only.\u003c/li\u003e\u003cli\u003eApplication Whitelisting \\u2013 Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software.\u003c/li\u003e\u003cli\u003eEndpoint Protection \\u2013 Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts.\u003c/li\u003e\u003cli\u003eLogging \u0026amp; Monitoring \\u2013 Enable and regularly review system logs to detect suspicious or unauthorized activity.\u003c/li\u003e\u003cli\u003eBackup \u0026amp; Recovery \\u2013 Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident.\u003c/li\u003e\u003cli\u003eOngoing Risk Assessment \\u2013 Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.\u003c/li\u003e\u003c/ul\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"datePublic\": \"2025-09-23T16:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-25-266-01\"}, {\"url\": \"https://www.automationdirect.com/support/software-downloads\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the generated private keys.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eA predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the generated private keys.\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\\n\\n\u003c/span\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-337\", \"description\": \"CWE-337 Predictable Seed in Pseudo-Random Number Generator\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2025-09-23T22:15:46.833Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-55069\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-24T14:07:59.115Z\", \"dateReserved\": \"2025-09-16T20:09:26.643Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2025-09-23T22:15:46.833Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…