CVE-2025-40948 (GCVE-0-2025-40948)

Vulnerability from cvelistv5 – Published: 2026-05-12 08:20 – Updated: 2026-05-12 12:43
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly validate input in the web server's JSON-RPC interface. This could allow an authenticated remote attacker to read arbitrary files from the underlying operating system's filesystem with root privileges.
CWE
  • CWE-88 - Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40948",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-12T12:43:17.469738Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-12T12:43:43.061Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX MX5000",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX MX5000RE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX RX1400",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX RX1500",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX RX1501",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX RX1510",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX RX1511",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX RX1512",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX RX1524",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX RX1536",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM ROX RX5000",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.17.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.17.1), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1400 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1500 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1501 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1510 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1511 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1512 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1524 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1536 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX5000 (All versions \u003c V2.17.1). Affected devices do not properly validate input in the web server\u0027s JSON-RPC interface.\r\n\r\nThis could allow an authenticated remote attacker to read arbitrary files from the underlying operating system\u0027s filesystem with root privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-88",
              "description": "CWE-88: Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-12T08:20:52.849Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-973901.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40948",
    "datePublished": "2026-05-12T08:20:52.849Z",
    "dateReserved": "2025-04-16T09:06:15.879Z",
    "dateUpdated": "2026-05-12T12:43:43.061Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-40948",
      "date": "2026-05-13",
      "epss": "0.00037",
      "percentile": "0.11224"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-40948\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2026-05-12T10:16:43.203\",\"lastModified\":\"2026-05-12T14:19:41.400\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.17.1), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1400 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1500 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1501 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1510 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1511 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1512 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1524 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1536 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX5000 (All versions \u003c V2.17.1). Affected devices do not properly validate input in the web server\u0027s JSON-RPC interface.\\r\\n\\r\\nThis could allow an authenticated remote attacker to read arbitrary files from the underlying operating system\u0027s filesystem with root privileges.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"HIGH\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":4.0}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-88\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-973901.html\",\"source\":\"productcert@siemens.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-40948\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-05-12T12:43:17.469738Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-05-12T12:43:38.870Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX MX5000\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX MX5000RE\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX RX1400\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX RX1500\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX RX1501\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX RX1510\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX RX1511\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX RX1512\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX RX1524\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX RX1536\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM ROX RX5000\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.17.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-973901.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.17.1), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1400 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1500 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1501 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1510 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1511 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1512 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1524 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX1536 (All versions \u003c V2.17.1), RUGGEDCOM ROX RX5000 (All versions \u003c V2.17.1). Affected devices do not properly validate input in the web server\u0027s JSON-RPC interface.\\r\\n\\r\\nThis could allow an authenticated remote attacker to read arbitrary files from the underlying operating system\u0027s filesystem with root privileges.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-88\", \"description\": \"CWE-88: Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2026-05-12T08:20:52.849Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-40948\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-05-12T12:43:43.061Z\", \"dateReserved\": \"2025-04-16T09:06:15.879Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2026-05-12T08:20:52.849Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…