CVE-2025-26336 (GCVE-0-2025-26336)
Vulnerability from cvelistv5
Published
2025-03-21 02:23
Modified
2025-03-21 13:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Dell | Dell Chassis Management Controller (CMC) for Dell PowerEdge FX2 |
Version: N/A ≤ |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-26336", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-21T13:59:37.293545Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-21T13:59:49.924Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Dell Chassis Management Controller (CMC) for Dell PowerEdge FX2", "vendor": "Dell", "versions": [ { "lessThan": "2.40.200.202101130302", "status": "affected", "version": "N/A", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Dell Chassis Management Controller (CMC) for PowerEdge VRTX", "vendor": "Dell", "versions": [ { "lessThan": "3.41.200.202209300499", "status": "affected", "version": "N/A", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Dell would like to thank Aliz Hammond of watchTowr for reporting these issues" } ], "datePublic": "2025-03-20T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.\u003cbr\u003e" } ], "value": "Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-21T02:23:46.785Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000297463/dsa-2025-123-security-update-for-dell-chassis-management-controller-firmware-for-dell-poweredge-fx2-and-vrtx-vulnerabilities" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2025-26336", "datePublished": "2025-03-21T02:23:46.785Z", "dateReserved": "2025-02-07T06:04:04.738Z", "dateUpdated": "2025-03-21T13:59:49.924Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-26336\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2025-03-21T03:15:12.000\",\"lastModified\":\"2025-03-27T16:08:17.900\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.\"},{\"lang\":\"es\",\"value\":\"Dell Chassis Management Controller Firmware para Dell PowerEdge FX2, versiones anteriores a la 2.40.200.202101130302, y Dell Chassis Management Controller Firmware para Dell PowerEdge VRTX, versiones anteriores a la 3.41.200.202209300499, presentan una vulnerabilidad de desbordamiento de b\u00fafer basado en pila. Un atacante no autenticado con acceso remoto podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda una ejecuci\u00f3n remota.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:H\",\"baseScore\":8.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:chassis_management_controller_for_poweredge_fx2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.40.200.202101130302\",\"matchCriteriaId\":\"86DEA45C-1FE5-49A0-A4F3-DCC9C2E96F9F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:chassis_management_controller_for_poweredge_fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85DD85AB-A95E-4CF3-8C08-BC939D9B2DD2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:chassis_management_controller_for_poweredge_vrtx_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.41.200.202209300499\",\"matchCriteriaId\":\"6C173E0A-300A-418A-A8CC-48A48759F0A9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:chassis_management_controller_for_poweredge_vrtx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F0F3696A-54A0-4BAD-B8A1-E0D54E4C2A84\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000297463/dsa-2025-123-security-update-for-dell-chassis-management-controller-firmware-for-dell-poweredge-fx2-and-vrtx-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-26336\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-03-21T13:59:37.293545Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-03-21T13:59:44.740Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Dell would like to thank Aliz Hammond of watchTowr for reporting these issues\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:H\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"Dell Chassis Management Controller (CMC) for Dell PowerEdge FX2\", \"versions\": [{\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"2.40.200.202101130302\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Dell\", \"product\": \"Dell Chassis Management Controller (CMC) for PowerEdge VRTX\", \"versions\": [{\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"3.41.200.202209300499\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-03-20T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000297463/dsa-2025-123-security-update-for-dell-chassis-management-controller-firmware-for-dell-poweredge-fx2-and-vrtx-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121: Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2025-03-21T02:23:46.785Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-26336\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-21T13:59:49.924Z\", \"dateReserved\": \"2025-02-07T06:04:04.738Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2025-03-21T02:23:46.785Z\", \"assignerShortName\": \"dell\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…