CVE-2025-24482 (GCVE-0-2025-24482)
Vulnerability from cvelistv5 – Published: 2025-01-28 20:59 – Updated: 2025-01-28 21:34
VLAI
EPSS
VEX
Title
FactoryTalk® View Site Edition - Local Code Injection
Summary
A Local Code Injection Vulnerability exists in the product and version listed above. The vulnerability is due to incorrect default permissions and allows for DLLs to be executed with higher level permissions.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-28 21:34 UTC
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Rockwell Automation | FactoryTalk® View Site Edition |
Affected:
<V15
|
guessed |
Date Public
2025-01-28 14:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-24482",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-28T21:34:07.646858Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T21:34:16.702Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae View Site Edition",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003cV15"
}
]
}
],
"datePublic": "2025-01-28T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA Local Code Injection Vulnerability exists in the product and version listed above. The vulnerability is due to incorrect default permissions and allows for DLLs to be executed with higher level permissions.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "A Local Code Injection Vulnerability exists in the product and version listed above. The vulnerability is due to incorrect default permissions and allows for DLLs to be executed with higher level permissions."
}
],
"impacts": [
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180: Exploiting Incorrectly Configured Access Control Security Levels"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T20:59:50.868Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1720.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to V15 or apply patch. Answer ID 1152304\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Upgrade to V15 or apply patch. Answer ID 1152304"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "FactoryTalk\u00ae View Site Edition - Local Code Injection",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCheck the environment variables (PATH), and make sure FactoryTalk\u00ae View SE installation path (C:\\Program Files (x86)\\Common Files\\Rockwell) is before all others\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Check the environment variables (PATH), and make sure FactoryTalk\u00ae View SE installation path (C:\\Program Files (x86)\\Common Files\\Rockwell) is before all others"
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-24482",
"datePublished": "2025-01-28T20:59:50.868Z",
"dateReserved": "2025-01-21T21:21:03.342Z",
"dateUpdated": "2025-01-28T21:34:16.702Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-24482",
"date": "2026-09-17",
"epss": "0.00252",
"percentile": "0.16933"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae View Site Edition",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003cV15"
}
]
}
],
"source": "PSIRT@rockwellautomation.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A Local Code Injection Vulnerability exists in the product and version listed above. The vulnerability is due to incorrect default permissions and allows for DLLs to be executed with higher level permissions."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de inyecci\u00f3n de c\u00f3digo local en el producto y la versi\u00f3n mencionados anteriormente. La vulnerabilidad se debe a permisos predeterminados incorrectos y permite que se ejecuten archivos DLL con permisos de nivel superior."
}
],
"id": "CVE-2025-24482",
"lastModified": "2026-06-17T08:59:05.900",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-24482",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-28T21:34:07.646858Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-01-28T21:15:18.687",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1720.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T17:05:58+00:00",
"cve": "CVE-2025-24482",
"id": "CVE-2025-24482",
"initial_release_date": "2025-01-28T14:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "FactoryTalk\u00ae View Site Edition - Local Code Injection",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-24482.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-24482",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-28T21:34:07.646858Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T21:34:11.711Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae View Site Edition",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003cV15"
}
]
}
],
"datePublic": "2025-01-28T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA Local Code Injection Vulnerability exists in the product and version listed above. The vulnerability is due to incorrect default permissions and allows for DLLs to be executed with higher level permissions.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "A Local Code Injection Vulnerability exists in the product and version listed above. The vulnerability is due to incorrect default permissions and allows for DLLs to be executed with higher level permissions."
}
],
"impacts": [
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180: Exploiting Incorrectly Configured Access Control Security Levels"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T20:59:50.868Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1720.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to V15 or apply patch. Answer ID 1152304\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Upgrade to V15 or apply patch. Answer ID 1152304"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "FactoryTalk\u00ae View Site Edition - Local Code Injection",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCheck the environment variables (PATH), and make sure FactoryTalk\u00ae View SE installation path (C:\\Program Files (x86)\\Common Files\\Rockwell) is before all others\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Check the environment variables (PATH), and make sure FactoryTalk\u00ae View SE installation path (C:\\Program Files (x86)\\Common Files\\Rockwell) is before all others"
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-24482",
"datePublished": "2025-01-28T20:59:50.868Z",
"dateReserved": "2025-01-21T21:21:03.342Z",
"dateUpdated": "2025-01-28T21:34:16.702Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…