CVE-2025-14134 (GCVE-0-2025-14134)
Vulnerability from cvelistv5
Published
2025-12-06 11:02
Modified
2025-12-08 17:14
CWE
Summary
A vulnerability was determined in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function RE2000v2Repeater_get_wireless_clientlist_setClientsName of the file mod_form.so. Executing manipulation of the argument clientsname_0 can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Linksys RE6500 Version: 1.0.013.001
Version: 1.0.04.001
Version: 1.0.04.002
Version: 1.1.05.003
Version: 1.2.07.001
Create a notification for this product.
   Linksys RE6250 Version: 1.0.013.001
Version: 1.0.04.001
Version: 1.0.04.002
Version: 1.1.05.003
Version: 1.2.07.001
Create a notification for this product.
   Linksys RE6300 Version: 1.0.013.001
Version: 1.0.04.001
Version: 1.0.04.002
Version: 1.1.05.003
Version: 1.2.07.001
Create a notification for this product.
   Linksys RE6350 Version: 1.0.013.001
Version: 1.0.04.001
Version: 1.0.04.002
Version: 1.1.05.003
Version: 1.2.07.001
Create a notification for this product.
   Linksys RE7000 Version: 1.0.013.001
Version: 1.0.04.001
Version: 1.0.04.002
Version: 1.1.05.003
Version: 1.2.07.001
Create a notification for this product.
   Linksys RE9000 Version: 1.0.013.001
Version: 1.0.04.001
Version: 1.0.04.002
Version: 1.1.05.003
Version: 1.2.07.001
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14134",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-08T17:07:14.777567Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-08T17:14:08.318Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md#poc"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RE6500",
          "vendor": "Linksys",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "product": "RE6250",
          "vendor": "Linksys",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "product": "RE6300",
          "vendor": "Linksys",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "product": "RE6350",
          "vendor": "Linksys",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "product": "RE7000",
          "vendor": "Linksys",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        },
        {
          "product": "RE9000",
          "vendor": "Linksys",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.013.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.001"
            },
            {
              "status": "affected",
              "version": "1.0.04.002"
            },
            {
              "status": "affected",
              "version": "1.1.05.003"
            },
            {
              "status": "affected",
              "version": "1.2.07.001"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "pjqwudi (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function RE2000v2Repeater_get_wireless_clientlist_setClientsName of the file mod_form.so. Executing manipulation of the argument clientsname_0 can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-06T11:02:06.912Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-334523 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.334523"
        },
        {
          "name": "VDB-334523 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.334523"
        },
        {
          "name": "Submit #697981 | Linksys RE6500\u3001RE6250\u3001RE6300\u3001RE6350\u3001RE7000\u3001RE9000 RE6500(1.0.013.001)  RE6250(1.0.04.001)  RE6300(1.2.07.001)  RE6350(1.0.04.001)  RE7000(1.1.05.003)  RE9000(1.0.04.002) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.697981"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.linksys.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-05T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-05T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-05T18:12:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-14134",
    "datePublished": "2025-12-06T11:02:06.912Z",
    "dateReserved": "2025-12-05T17:07:15.702Z",
    "dateUpdated": "2025-12-08T17:14:08.318Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-14134\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-12-06T11:15:48.437\",\"lastModified\":\"2025-12-10T18:00:27.810\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was determined in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function RE2000v2Repeater_get_wireless_clientlist_setClientsName of the file mod_form.so. Executing manipulation of the argument clientsname_0 can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"},{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"92354C9C-D1B2-4143-803D-DE5EF7842184\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"52622B22-2E42-443B-81DA-7C42ECCF0564\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"70728D67-153A-49FA-80E2-0DE9086DA253\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"898FD49F-4225-47FF-822C-9E4FFB5EE192\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E3A6A93-D598-4F52-808C-EAA45B468066\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"25647318-6422-418C-99B8-C806FF490028\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FFD3F65-E520-415D-BAB8-57FACEA5BEC7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8DC2325A-068F-4B5E-A365-6BF1103E320E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D04E83B6-EE99-42EB-AA37-895B1467CEDA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11F24125-412F-473A-BF34-02284F8DAC2D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7424D2C2-BCF4-4B2D-BE59-71B50B13FE77\"}]}]}],\"references\":[{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md#poc\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.334523\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.334523\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.697981\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.linksys.com/\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Product\"]},{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md#poc\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-14134\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-12-08T17:07:14.777567Z\"}}}], \"references\": [{\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md#poc\", \"tags\": [\"exploit\"]}, {\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md\", \"tags\": [\"exploit\"]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-12-08T17:07:17.480Z\"}}], \"cna\": {\"title\": \"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"pjqwudi (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"vendor\": \"Linksys\", \"product\": \"RE6500\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6250\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6300\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6350\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE7000\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE9000\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-12-05T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-12-05T01:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-12-05T18:12:28.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.334523\", \"name\": \"VDB-334523 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.334523\", \"name\": \"VDB-334523 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.697981\", \"name\": \"Submit #697981 | Linksys RE6500\\u3001RE6250\\u3001RE6300\\u3001RE6350\\u3001RE7000\\u3001RE9000 RE6500(1.0.013.001)  RE6250(1.0.04.001)  RE6300(1.2.07.001)  RE6350(1.0.04.001)  RE7000(1.1.05.003)  RE9000(1.0.04.002) Stack-based Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md\", \"tags\": [\"related\"]}, {\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_63/63.md#poc\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.linksys.com/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was determined in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function RE2000v2Repeater_get_wireless_clientlist_setClientsName of the file mod_form.so. Executing manipulation of the argument clientsname_0 can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"Stack-based Buffer Overflow\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"Memory Corruption\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-12-06T11:02:06.912Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-14134\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-12-08T17:14:08.318Z\", \"dateReserved\": \"2025-12-05T17:07:15.702Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-12-06T11:02:06.912Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…