CVE-2024-5560 (GCVE-0-2024-5560)
Vulnerability from cvelistv5 – Published: 2024-06-12 16:45 – Updated: 2024-08-01 21:18- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Sage 1410 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_4400",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5560",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T18:30:24.462387Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T18:32:10.472Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.538Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Sage 1410",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1430",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1450",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 2400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 3030 Magnum",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 4400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request.\n\n"
}
],
"value": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T16:45:56.256Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5560",
"datePublished": "2024-06-12T16:45:56.256Z",
"dateReserved": "2024-05-31T06:58:55.638Z",
"dateUpdated": "2024-08-01T21:18:06.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:sage_rtu_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"c3414-500-s02k5_p9\", \"matchCriteriaId\": \"D4DDD3DD-576C-404E-A132-D1357936A610\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"02E606BD-92F8-4396-AD13-666D76E1E34D\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"97E29CCC-4E21-411E-80DD-545A66E9B042\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"66759867-027F-4FA6-ABA6-BFDEE49E8F8D\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AA561E2A-4787-48D7-ABBB-26D0D7D24E6F\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"453696F2-0F4C-4000-A438-F814D0FC3504\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6462B366-8F9F-49D6-939A-E73C1D5A707C\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\\ndevice\\u2019s web interface when an attacker sends a specially crafted HTTP request.\"}, {\"lang\": \"es\", \"value\": \"CWE-125: Existe una vulnerabilidad de lectura fuera de los l\\u00edmites que podr\\u00eda causar denegaci\\u00f3n de servicio de la interfaz web del dispositivo cuando un atacante env\\u00eda una solicitud HTTP especialmente manipulada.\"}]",
"id": "CVE-2024-5560",
"lastModified": "2024-11-21T09:47:55.983",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2024-06-12T17:15:52.357",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-5560\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2024-06-12T17:15:52.357\",\"lastModified\":\"2024-11-21T09:47:55.983\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request.\"},{\"lang\":\"es\",\"value\":\"CWE-125: Existe una vulnerabilidad de lectura fuera de los l\u00edmites que podr\u00eda causar denegaci\u00f3n de servicio de la interfaz web del dispositivo cuando un atacante env\u00eda una solicitud HTTP especialmente manipulada.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:sage_rtu_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"c3414-500-s02k5_p9\",\"matchCriteriaId\":\"D4DDD3DD-576C-404E-A132-D1357936A610\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"02E606BD-92F8-4396-AD13-666D76E1E34D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"97E29CCC-4E21-411E-80DD-545A66E9B042\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66759867-027F-4FA6-ABA6-BFDEE49E8F8D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA561E2A-4787-48D7-ABBB-26D0D7D24E6F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"453696F2-0F4C-4000-A438-F814D0FC3504\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6462B366-8F9F-49D6-939A-E73C1D5A707C\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T21:18:06.538Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-5560\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-06-12T18:30:24.462387Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*\", \"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*\", \"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*\", \"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*\", \"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*\", \"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*\"], \"vendor\": \"schneider-electric\", \"product\": \"sage_4400\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"c3414-500-s02k5_p8\"}], \"defaultStatus\": \"unaffected\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-12T18:30:17.592Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Sage 1410\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 1430\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 1450\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 2400\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 3030 Magnum\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 4400\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\\ndevice\\u2019s web interface when an attacker sends a specially crafted HTTP request.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nCWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\\ndevice\\u2019s web interface when an attacker sends a specially crafted HTTP request.\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-125\", \"description\": \"CWE-125 Out-of-bounds Read\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2024-06-12T16:45:56.256Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-5560\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T21:18:06.538Z\", \"dateReserved\": \"2024-05-31T06:58:55.638Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2024-06-12T16:45:56.256Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CVE-2024-5560
Vulnerability from csaf_se - Published: 2024-06-11 00:00 - Updated: 2024-07-09 00:00CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its SAGE RTU products.\r\nThe SAGE RTU products are hardware devices that collect utility substation information from\r\ndifferent devices and passes it along to a SCADA software platform.\r\nFailure to apply the remediation provided below may risk total compromise of the impacted\r\ndevice, leading to loss of data, loss of operation, or impacts to the performance of the device.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "SAGE RTU - SEVD-2024-163-05 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
},
{
"category": "self",
"summary": "SAGE RTU - SEVD-2024-163-05 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2024-163-05.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "SAGE RTU",
"tracking": {
"current_release_date": "2024-07-09T00:00:00.000Z",
"generator": {
"date": "2024-06-09T14:07:02.956Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2024-163-05",
"initial_release_date": "2024-06-11T00:00:00.000Z",
"revision_history": [
{
"date": "2024-06-11T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2024-06-11T00:00:00.000Z",
"number": "1.1.0",
"summary": "Mitigations were provided to address this vulnerability. Also, there was an update to the affected product version."
},
{
"date": "2024-07-09T00:00:00.000Z",
"number": "2.0.0",
"summary": "A direct link is now available to the remediation."
}
],
"status": "final",
"version": "2.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 1410 Versions C3414-500-S02K5_P8 and prior",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Sage 1410"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 1430 Versions C3414-500-S02K5_P8 and prior",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Sage 1430"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 1450 Versions C3414-500-S02K5_P8 and prior",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Sage 1450"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 2400 Versions C3414-500-S02K5_P8 and prior",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Sage 2400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 3030 Magnum Versions C3414-500-S02K5_P8 and prior",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Sage 3030 Magnum"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 4400 Versions C3414-500-S02K5_P8 and prior",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Sage 4400"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 1410 C3414-500-S02K5_P9",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "Sage 1410"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 1430 C3414-500-S02K5_P9",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "Sage 1430"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 1450 C3414-500-S02K5_P9",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "Sage 1450"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 2400 C3414-500-S02K5_P9",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "Sage 2400"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 3030 Magnum C3414-500-S02K5_P9",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "Sage 3030 Magnum"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 4400 C3414-500-S02K5_P9",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "Sage 4400"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Alex Armstrong"
],
"organization": "LLNL"
}
],
"cve": "CVE-2024-37036",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\r\nwhen sending a malformed POST request and particular configuration parameters are set.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2024-37036"
},
{
"acknowledgments": [
{
"names": [
"Alex Armstrong"
],
"organization": "LLNL"
}
],
"cve": "CVE-2024-37037",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\r\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\r\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\r\nrequest.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2024-37037"
},
{
"acknowledgments": [
{
"names": [
"Vishal Madipadga"
],
"organization": "SNL"
}
],
"cve": "CVE-2024-37038",
"cwe": {
"id": "CWE-276",
"name": "Incorrect Default Permissions"
},
"notes": [
{
"category": "description",
"text": "CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\r\nuser with access to the device\u2019s web interface to perform unauthorized file and firmware\r\nuploads when crafting custom web requests.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2024-37038"
},
{
"acknowledgments": [
{
"names": [
"Alex Armstrong"
],
"organization": "LLNL"
}
],
"cve": "CVE-2024-37039",
"cwe": {
"id": "CWE-252",
"name": "Unchecked Return Value"
},
"notes": [
{
"category": "description",
"text": "CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\r\ndevice when an attacker sends a specially crafted HTTP request.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2024-37039"
},
{
"acknowledgments": [
{
"names": [
"Alex Armstrong"
],
"organization": "LLNL"
}
],
"cve": "CVE-2024-37040",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\r\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\r\ndevice when sending a malformed HTTP request.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2024-37040"
},
{
"acknowledgments": [
{
"names": [
"Vishal Madipadga"
],
"organization": "SNL"
}
],
"cve": "CVE-2024-5560",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "description",
"text": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\r\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2024-5560"
}
]
}
FKIE_CVE-2024-5560
Vulnerability from fkie_nvd - Published: 2024-06-12 17:15 - Updated: 2024-11-21 09:477.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:sage_rtu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D4DDD3DD-576C-404E-A132-D1357936A610",
"versionEndExcluding": "c3414-500-s02k5_p9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
"matchCriteriaId": "02E606BD-92F8-4396-AD13-666D76E1E34D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97E29CCC-4E21-411E-80DD-545A66E9B042",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
"matchCriteriaId": "66759867-027F-4FA6-ABA6-BFDEE49E8F8D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AA561E2A-4787-48D7-ABBB-26D0D7D24E6F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
"matchCriteriaId": "453696F2-0F4C-4000-A438-F814D0FC3504",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6462B366-8F9F-49D6-939A-E73C1D5A707C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request."
},
{
"lang": "es",
"value": "CWE-125: Existe una vulnerabilidad de lectura fuera de los l\u00edmites que podr\u00eda causar denegaci\u00f3n de servicio de la interfaz web del dispositivo cuando un atacante env\u00eda una solicitud HTTP especialmente manipulada."
}
],
"id": "CVE-2024-5560",
"lastModified": "2024-11-21T09:47:55.983",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-06-12T17:15:52.357",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
CNVD-2024-29561
Vulnerability from cnvd - Published: 2024-06-28厂商已发布了漏洞修复程序,请及时关注更新: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf
| Name | ['Schneider Electric Sage 1410 <=C3414-500-S02K5_P8', 'Schneider Electric Sage 1430 <=C3414-500-S02K5_P8', 'Schneider Electric Sage 1450 <=C3414-500-S02K5_P8', 'Schneider Electric Sage 2400 <=C3414-500-S02K5_P8', 'Schneider Electric Sage 3030 Magnum <=C3414-500-S02K5_P8', 'Schneider Electric Sage 4400 <=C3414-500-S02K5_P8'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2024-5560",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2024-5560"
}
},
"description": "Schneider Electric SAGE RTUs\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u7528\u4e8e\u5de5\u4e1a\u81ea\u52a8\u5316\u548c\u8fdc\u7a0b\u76d1\u63a7\u7684\u9ad8\u6027\u80fd\u8bbe\u5907\u3002\n\nSchneider Electric SAGE RTUs\u5b58\u5728\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u901a\u8fc7\u53d1\u9001\u7279\u5236\u7684HTTP\u8bf7\u6c42\uff0c\u5bfc\u81f4\u8bbe\u5907Web\u754c\u9762\u62d2\u7edd\u670d\u52a1\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2024-29561",
"openTime": "2024-06-28",
"patchDescription": "Schneider Electric SAGE RTUs\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u7528\u4e8e\u5de5\u4e1a\u81ea\u52a8\u5316\u548c\u8fdc\u7a0b\u76d1\u63a7\u7684\u9ad8\u6027\u80fd\u8bbe\u5907\u3002\r\n\r\nSchneider Electric SAGE RTUs\u5b58\u5728\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u901a\u8fc7\u53d1\u9001\u7279\u5236\u7684HTTP\u8bf7\u6c42\uff0c\u5bfc\u81f4\u8bbe\u5907Web\u754c\u9762\u62d2\u7edd\u670d\u52a1\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric SAGE RTUs\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Schneider Electric Sage 1410 \u003c=C3414-500-S02K5_P8",
"Schneider Electric Sage 1430 \u003c=C3414-500-S02K5_P8",
"Schneider Electric Sage 1450 \u003c=C3414-500-S02K5_P8",
"Schneider Electric Sage 2400 \u003c=C3414-500-S02K5_P8",
"Schneider Electric Sage 3030 Magnum \u003c=C3414-500-S02K5_P8",
"Schneider Electric Sage 4400 \u003c=C3414-500-S02K5_P8"
]
},
"referenceLink": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf",
"serverity": "\u4e2d",
"submitTime": "2024-06-18",
"title": "Schneider Electric SAGE RTUs\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e"
}
CVE-2024-5560
Vulnerability from fstec - Published: 11.06.2024{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e C3414-500-S02K5_P9 (Sage 1410), \u0434\u043e C3414-500-S02K5_P9 (Sage 1430), \u0434\u043e C3414-500-S02K5_P9 (Sage 1450), \u0434\u043e C3414-500-S02K5_P9 (Sage 2400), \u0434\u043e C3414-500-S02K5_P9 (Sage 3030 Magnum), \u0434\u043e C3414-500-S02K5_P9 (Sage 4400)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f:\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "11.06.2024",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "20.06.2024",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "20.06.2024",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2024-04689",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2024-5560",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Sage 1410, Sage 1430, Sage 1450, Sage 2400, Sage 3030 Magnum, Sage 4400",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0432\u0435\u0431-\u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430 \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0434\u0438\u0441\u0442\u0430\u043d\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u0435\u043c \u0438 \u044d\u043d\u0435\u0440\u0433\u043e\u043f\u043e\u0442\u0440\u0435\u0431\u043b\u0435\u043d\u0438\u0435\u043c Schneider Electric Sage, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u0427\u0442\u0435\u043d\u0438\u0435 \u0437\u0430 \u0433\u0440\u0430\u043d\u0438\u0446\u0430\u043c\u0438 \u0431\u0443\u0444\u0435\u0440\u0430 (CWE-125)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0432\u0435\u0431-\u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u0430 \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0434\u0438\u0441\u0442\u0430\u043d\u0446\u0438\u043e\u043d\u043d\u043e\u0433\u043e \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u0435\u043c \u0438 \u044d\u043d\u0435\u0440\u0433\u043e\u043f\u043e\u0442\u0440\u0435\u0431\u043b\u0435\u043d\u0438\u0435\u043c Schneider Electric Sage \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u0447\u0442\u0435\u043d\u0438\u0435\u043c \u0434\u0430\u043d\u043d\u044b\u0445 \u0437\u0430 \u0433\u0440\u0430\u043d\u0438\u0446\u0430\u043c\u0438 \u0431\u0443\u0444\u0435\u0440\u0430 \u0432 \u043f\u0430\u043c\u044f\u0442\u0438. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u043e\u0437\u0434\u0430\u043d\u043d\u043e\u0433\u043e HTTP-\u0437\u0430\u043f\u0440\u043e\u0441\u0430",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430\u043c\u0438 \u0434\u0430\u043d\u043d\u044b\u0445",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-125",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 5)\n\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 5,3)"
}
NCSC-2024-0244
Vulnerability from csaf_ncscnl - Published: 2024-06-11 11:33 - Updated: 2024-06-11 11:33{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "nl",
"notes": [
{
"category": "legal_disclaimer",
"text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings."
},
{
"category": "description",
"text": "Schneider Electric heeft kwetsbaarheden verholpen in Sage RTU apparatuur.",
"title": "Feiten"
},
{
"category": "description",
"text": "Een kwaadwillende kan de kwetsbaarheden misbruiken om aanvallen uit te voeren die kunnen leiden tot de volgende categorie\u00ebn schade:\n\n- Denial-of-Service (DoS)\n- Manipulatie van gegevens\n- Omzeilen van authenticatie\n- Omzeilen van beveiligingsmaatregel\n- (Remote) code execution (Administrator/Root rechten)\n- (Remote) code execution (Gebruikersrechten)\n- Toegang tot systeemgegevens\n\nVoor succesvol misbruik moet de kwaadwillende toegang hebben tot de productieomgeving. Het is goed gebruik een dergelijke infrastructuur niet publiek toegankelijk te hebben.",
"title": "Interpretaties"
},
{
"category": "description",
"text": "Schneider Electric heeft updates uitgebracht van de firmware om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.",
"title": "Oplossingen"
},
{
"category": "general",
"text": "medium",
"title": "Kans"
},
{
"category": "general",
"text": "high",
"title": "Schade"
},
{
"category": "general",
"text": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"title": "CWE-120"
},
{
"category": "general",
"text": "Out-of-bounds Read",
"title": "CWE-125"
},
{
"category": "general",
"text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"title": "CWE-22"
},
{
"category": "general",
"text": "Unchecked Return Value",
"title": "CWE-252"
},
{
"category": "general",
"text": "Incorrect Default Permissions",
"title": "CWE-276"
},
{
"category": "general",
"text": "Out-of-bounds Write",
"title": "CWE-787"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "cert@ncsc.nl",
"name": "Nationaal Cyber Security Centrum",
"namespace": "https://www.ncsc.nl/"
},
"references": [
{
"category": "external",
"summary": "Source - schneider",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2024-163-05.json"
},
{
"category": "external",
"summary": "Reference - schneider",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2024-163-05.pdf"
}
],
"title": "Kwetsbaarheden verholpen in Schneider Electric Sage RTU systemen",
"tracking": {
"current_release_date": "2024-06-11T11:33:48.933251Z",
"id": "NCSC-2024-0244",
"initial_release_date": "2024-06-11T11:33:48.933251Z",
"revision_history": [
{
"date": "2024-06-11T11:33:48.933251Z",
"number": "0",
"summary": "Initiele versie"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"category": "product_name",
"name": "sage_1410",
"product": {
"name": "sage_1410",
"product_id": "CSAFPID-1021755",
"product_identification_helper": {
"cpe": "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "sage_1430",
"product": {
"name": "sage_1430",
"product_id": "CSAFPID-1021756",
"product_identification_helper": {
"cpe": "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "sage_1450",
"product": {
"name": "sage_1450",
"product_id": "CSAFPID-1021757",
"product_identification_helper": {
"cpe": "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "sage_2400",
"product": {
"name": "sage_2400",
"product_id": "CSAFPID-1021759",
"product_identification_helper": {
"cpe": "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "sage_3030_magnum",
"product": {
"name": "sage_3030_magnum",
"product_id": "CSAFPID-1240183",
"product_identification_helper": {
"cpe": "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "sage_4400",
"product": {
"name": "sage_4400",
"product_id": "CSAFPID-1475940",
"product_identification_helper": {
"cpe": "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
}
}
}
],
"category": "vendor",
"name": "schneider-electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-37036",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "other",
"text": "Out-of-bounds Write",
"title": "CWE-787"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1021755",
"CSAFPID-1021756",
"CSAFPID-1021757",
"CSAFPID-1021759",
"CSAFPID-1240183"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2024-37036",
"url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37036.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1021755",
"CSAFPID-1021756",
"CSAFPID-1021757",
"CSAFPID-1021759",
"CSAFPID-1240183"
]
}
],
"title": "CVE-2024-37036"
},
{
"cve": "CVE-2024-37037",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "other",
"text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"title": "CWE-22"
}
],
"references": [
{
"category": "self",
"summary": "CVE-2024-37037",
"url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37037.json"
}
],
"title": "CVE-2024-37037"
},
{
"cve": "CVE-2024-37038",
"cwe": {
"id": "CWE-276",
"name": "Incorrect Default Permissions"
},
"notes": [
{
"category": "other",
"text": "Incorrect Default Permissions",
"title": "CWE-276"
}
],
"references": [
{
"category": "self",
"summary": "CVE-2024-37038",
"url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37038.json"
}
],
"title": "CVE-2024-37038"
},
{
"cve": "CVE-2024-37039",
"cwe": {
"id": "CWE-252",
"name": "Unchecked Return Value"
},
"notes": [
{
"category": "other",
"text": "Unchecked Return Value",
"title": "CWE-252"
}
],
"references": [
{
"category": "self",
"summary": "CVE-2024-37039",
"url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37039.json"
}
],
"title": "CVE-2024-37039"
},
{
"cve": "CVE-2024-37040",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "other",
"text": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"title": "CWE-120"
}
],
"references": [
{
"category": "self",
"summary": "CVE-2024-37040",
"url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37040.json"
}
],
"title": "CVE-2024-37040"
},
{
"cve": "CVE-2024-5560",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "other",
"text": "Out-of-bounds Read",
"title": "CWE-125"
}
],
"references": [
{
"category": "self",
"summary": "CVE-2024-5560",
"url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-5560.json"
}
],
"title": "CVE-2024-5560"
}
]
}
GHSA-X36J-WQPG-PV3X
Vulnerability from github – Published: 2024-06-12 18:30 – Updated: 2024-07-25 21:31CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
{
"affected": [],
"aliases": [
"CVE-2024-5560"
],
"database_specific": {
"cwe_ids": [
"CWE-125"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2024-06-12T17:15:52Z",
"severity": "MODERATE"
},
"details": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request.",
"id": "GHSA-x36j-wqpg-pv3x",
"modified": "2024-07-25T21:31:19Z",
"published": "2024-06-12T18:30:41Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-5560"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"type": "CVSS_V3"
}
]
}
ICSA-25-107-02
Vulnerability from csaf_cisa - Published: 2024-06-11 00:00 - Updated: 2024-07-09 00:00CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
| URL | Category | ||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||
{
"document": {
"acknowledgments": [
{
"names": [
"Marlon Schumacher",
"Alex Armstrong"
],
"organization": "LLNL",
"summary": "reporting these vulnerabilities to Schneider Electric"
},
{
"names": [
"Vishal Madipadga"
],
"organization": "SNL",
"summary": "reporting these vulnerabilities to Schneider Electric"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its SAGE RTU products.\r\nThe SAGE RTU products are hardware devices that collect utility substation information from\r\ndifferent devices and passes it along to a SCADA software platform.\r\nFailure to apply the remediation provided below may risk total compromise of the impacted\r\ndevice, leading to loss of data, loss of operation, or impacts to the performance of the device.",
"title": "Overview"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Schneider Electric CPCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SAGE RTU - SEVD-2024-163-05 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2024-163-05.json"
},
{
"category": "self",
"summary": "SAGE RTU - SEVD-2024-163-05 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2024-163-05.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-107-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-107-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-107-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-107-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric Sage Series",
"tracking": {
"current_release_date": "2024-07-09T00:00:00.000000Z",
"generator": {
"date": "2025-04-17T20:00:11.972086Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-107-02",
"initial_release_date": "2024-06-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2024-06-11T00:00:00.000000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2024-06-11T00:00:00.000000Z",
"number": "1.1.0",
"summary": "Mitigations were provided to address this vulnerability. Also, there was an update to the affected product version."
},
{
"date": "2024-07-09T00:00:00.000000Z",
"number": "2.0.0",
"summary": "A direct link is now available to the remediation."
}
],
"status": "final",
"version": "2.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 1410 Versions C3414-500-S02K5_P8 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Sage 1410"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 1430 Versions C3414-500-S02K5_P8 and prior",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Sage 1430"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 1450 Versions C3414-500-S02K5_P8 and prior",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Sage 1450"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 2400 Versions C3414-500-S02K5_P8 and prior",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Sage 2400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 3030 Magnum Versions C3414-500-S02K5_P8 and prior",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "Sage 3030 Magnum"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003c=C3414-500-S02K5_P8",
"product": {
"name": "Schneider Electric Sage 4400 Versions C3414-500-S02K5_P8 and prior",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "Sage 4400"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 1410 C3414-500-S02K5_P9",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "Sage 1410"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 1430 C3414-500-S02K5_P9",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "Sage 1430"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 1450 C3414-500-S02K5_P9",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "Sage 1450"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 2400 C3414-500-S02K5_P9",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "Sage 2400"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 3030 Magnum C3414-500-S02K5_P9",
"product_id": "CSAFPID-0011"
}
}
],
"category": "product_name",
"name": "Sage 3030 Magnum"
},
{
"branches": [
{
"category": "product_version",
"name": "C3414-500-S02K5_P9",
"product": {
"name": "Schneider Electric Sage 4400 C3414-500-S02K5_P9",
"product_id": "CSAFPID-0012"
}
}
],
"category": "product_name",
"name": "Sage 4400"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Alex Armstrong"
],
"organization": "LLNL"
}
],
"cve": "CVE-2024-37036",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\r\nwhen sending a malformed POST request and particular configuration parameters are set.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2024-37036"
},
{
"acknowledgments": [
{
"names": [
"Alex Armstrong"
],
"organization": "LLNL"
}
],
"cve": "CVE-2024-37037",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\r\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\r\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\r\nrequest.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2024-37037"
},
{
"acknowledgments": [
{
"names": [
"Vishal Madipadga"
],
"organization": "SNL"
}
],
"cve": "CVE-2024-37038",
"cwe": {
"id": "CWE-276",
"name": "Incorrect Default Permissions"
},
"notes": [
{
"category": "description",
"text": "CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\r\nuser with access to the device\u2019s web interface to perform unauthorized file and firmware\r\nuploads when crafting custom web requests.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2024-37038"
},
{
"acknowledgments": [
{
"names": [
"Alex Armstrong"
],
"organization": "LLNL"
}
],
"cve": "CVE-2024-37039",
"cwe": {
"id": "CWE-252",
"name": "Unchecked Return Value"
},
"notes": [
{
"category": "description",
"text": "CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\r\ndevice when an attacker sends a specially crafted HTTP request.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2024-37039"
},
{
"acknowledgments": [
{
"names": [
"Alex Armstrong"
],
"organization": "LLNL"
}
],
"cve": "CVE-2024-37040",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\r\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\r\ndevice when sending a malformed HTTP request.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2024-37040"
},
{
"acknowledgments": [
{
"names": [
"Vishal Madipadga"
],
"organization": "SNL"
}
],
"cve": "CVE-2024-5560",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "description",
"text": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\r\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware version C3414-500-S02K5_P9 of SAGE RTU includes a fix for these vulnerabilities and is available for download here:https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/C3414-500-S02K5_P9_Firmware/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2024-5560"
}
]
}
VAR-202406-0247
Vulnerability from variot - Updated: 2024-07-04 23:01CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request. Schneider Electric SAGE RTUs is a high-performance device for industrial automation and remote monitoring from Schneider Electric, a French company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202406-0247",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "electric sage \u003c=c3414-500-s02k5 p8",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "1410"
},
{
"model": "electric sage \u003c=c3414-500-s02k5 p8",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "1430"
},
{
"model": "electric sage \u003c=c3414-500-s02k5 p8",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "1450"
},
{
"model": "electric sage \u003c=c3414-500-s02k5 p8",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "2400"
},
{
"model": "electric sage magnum \u003c=c3414-500-s02k5 p8",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "3030"
},
{
"model": "electric sage \u003c=c3414-500-s02k5 p8",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "4400"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-29561"
}
]
},
"cve": "CVE-2024-5560",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-29561",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cybersecurity@se.com",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
],
"severity": [
{
"author": "cybersecurity@se.com",
"id": "CVE-2024-5560",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2024-29561",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-29561"
},
{
"db": "NVD",
"id": "CVE-2024-5560"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request. Schneider Electric SAGE RTUs is a high-performance device for industrial automation and remote monitoring from Schneider Electric, a French company",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-5560"
},
{
"db": "CNVD",
"id": "CNVD-2024-29561"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-5560",
"trust": 1.6
},
{
"db": "SCHNEIDER",
"id": "SEVD-2024-163-05",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-29561",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-29561"
},
{
"db": "NVD",
"id": "CVE-2024-5560"
}
]
},
"id": "VAR-202406-0247",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-29561"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-29561"
}
]
},
"last_update_date": "2024-07-04T23:01:16.144000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Schneider Electric SAGE RTUs Out-of-Bounds Read Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/563696"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-29561"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2024-5560"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2024-163-05\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2024-163-05.pdf"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-29561"
},
{
"db": "NVD",
"id": "CVE-2024-5560"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-29561"
},
{
"db": "NVD",
"id": "CVE-2024-5560"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-06-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-29561"
},
{
"date": "2024-06-12T17:15:52.357000",
"db": "NVD",
"id": "CVE-2024-5560"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-06-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-29561"
},
{
"date": "2024-06-13T18:36:09.010000",
"db": "NVD",
"id": "CVE-2024-5560"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric SAGE RTUs Out-of-Bounds Read Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-29561"
}
],
"trust": 0.6
}
}
CERTFR-2024-AVI-0476
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une élévation de privilèges, un déni de service à distance et une atteinte à la confidentialité des données.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | Sage 2400 | Sage 2400 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions | ||
| Schneider Electric | Sage 1450 | Sage 1450 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 1430 | Sage 1430 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 3030 Magnum | Sage 3030 Magnum avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 1410 | Sage 1410 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | EVlink Home Smart | EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 antérieures à 2.0.5.0.0_134 | ||
| Schneider Electric | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | ||
| Schneider Electric | Modicon M340 | Modicon M340 toutes versions | ||
| Schneider Electric | PowerLogic P5 | PowerLogic P5 versions antérieures à 02.501.101 | ||
| Schneider Electric | Sage 4400 | Sage 4400 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | N/A | SpaceLogic AS-P et SpaceLogic AS-B versions antérieures à 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de sécurité | ||
| Schneider Electric | Network module, Modicon M340, Modbus/TCP BMXNOE0100 | Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Sage 2400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 2400",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions",
"product": {
"name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1450 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1450",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1430 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1430",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 3030 Magnum avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 3030 Magnum",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1410 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1410",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 ant\u00e9rieures \u00e0 2.0.5.0.0_134",
"product": {
"name": "EVlink Home Smart",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"product": {
"name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PowerLogic P5 versions ant\u00e9rieures \u00e0 02.501.101",
"product": {
"name": "PowerLogic P5",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 4400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 4400",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic AS-P et SpaceLogic AS-B versions ant\u00e9rieures \u00e0 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions",
"product": {
"name": "Network module, Modicon M340, Modbus/TCP BMXNOE0100",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-5557",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5557"
},
{
"name": "CVE-2024-37039",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37039"
},
{
"name": "CVE-2024-5558",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5558"
},
{
"name": "CVE-2024-5056",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5056"
},
{
"name": "CVE-2024-37037",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37037"
},
{
"name": "CVE-2024-5559",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5559"
},
{
"name": "CVE-2024-5313",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5313"
},
{
"name": "CVE-2024-37038",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37038"
},
{
"name": "CVE-2024-37040",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37040"
},
{
"name": "CVE-2024-5560",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5560"
},
{
"name": "CVE-2024-37036",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37036"
}
],
"links": [],
"reference": "CERTFR-2024-AVI-0476",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-06-11T00:00:00.000000"
},
{
"description": "Ajout des identifiants CVE.",
"revision_date": "2024-06-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une \u00e9l\u00e9vation de privil\u00e8ges, un d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-02.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-01.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
}
]
}
CERTFR-2024-AVI-0476
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une élévation de privilèges, un déni de service à distance et une atteinte à la confidentialité des données.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | Sage 2400 | Sage 2400 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions | ||
| Schneider Electric | Sage 1450 | Sage 1450 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 1430 | Sage 1430 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 3030 Magnum | Sage 3030 Magnum avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 1410 | Sage 1410 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | EVlink Home Smart | EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 antérieures à 2.0.5.0.0_134 | ||
| Schneider Electric | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | ||
| Schneider Electric | Modicon M340 | Modicon M340 toutes versions | ||
| Schneider Electric | PowerLogic P5 | PowerLogic P5 versions antérieures à 02.501.101 | ||
| Schneider Electric | Sage 4400 | Sage 4400 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | N/A | SpaceLogic AS-P et SpaceLogic AS-B versions antérieures à 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de sécurité | ||
| Schneider Electric | Network module, Modicon M340, Modbus/TCP BMXNOE0100 | Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Sage 2400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 2400",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions",
"product": {
"name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1450 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1450",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1430 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1430",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 3030 Magnum avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 3030 Magnum",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1410 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1410",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 ant\u00e9rieures \u00e0 2.0.5.0.0_134",
"product": {
"name": "EVlink Home Smart",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"product": {
"name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PowerLogic P5 versions ant\u00e9rieures \u00e0 02.501.101",
"product": {
"name": "PowerLogic P5",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 4400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 4400",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic AS-P et SpaceLogic AS-B versions ant\u00e9rieures \u00e0 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions",
"product": {
"name": "Network module, Modicon M340, Modbus/TCP BMXNOE0100",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-5557",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5557"
},
{
"name": "CVE-2024-37039",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37039"
},
{
"name": "CVE-2024-5558",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5558"
},
{
"name": "CVE-2024-5056",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5056"
},
{
"name": "CVE-2024-37037",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37037"
},
{
"name": "CVE-2024-5559",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5559"
},
{
"name": "CVE-2024-5313",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5313"
},
{
"name": "CVE-2024-37038",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37038"
},
{
"name": "CVE-2024-37040",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37040"
},
{
"name": "CVE-2024-5560",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5560"
},
{
"name": "CVE-2024-37036",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37036"
}
],
"links": [],
"reference": "CERTFR-2024-AVI-0476",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-06-11T00:00:00.000000"
},
{
"description": "Ajout des identifiants CVE.",
"revision_date": "2024-06-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une \u00e9l\u00e9vation de privil\u00e8ges, un d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-02.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-01.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.