GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-37036 (GCVE-0-2024-37036)

Vulnerability from cvelistv5 – Published: 2024-06-12 16:48 – Updated: 2024-08-02 03:43
VLAI
Summary
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-12 17:43 UTC
CWE
Impacted products
Vendor Product Version CPE status
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
guessed Create a notification for this product.
Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
guessed Create a notification for this product.
Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
guessed Create a notification for this product.
Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
guessed Create a notification for this product.
Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
guessed Create a notification for this product.
Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
guessed Create a notification for this product.
schneider_electric sage_4400_firmware Affected: 0 , ≤ C3414-500-S02K5_P8 (custom)
    cpe:2.3:o:schneider_electric:sage_1410_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:schneider_electric:sage_1430_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:schneider_electric:sage_1450_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:schneider_electric:sage_2400_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:schneider_electric:sage_3030_magnum_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:schneider_electric:sage_4400_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:schneider_electric:sage_1410_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_1430_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_1450_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_2400_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_3030_magnum_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_4400_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sage_4400_firmware",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "C3414-500-S02K5_P8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37036",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T17:43:17.841310Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T17:57:45.916Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.996Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\nCWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\nwhen sending a malformed POST request and particular configuration parameters are set.\n\n\n\n"
            }
          ],
          "value": "CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\nwhen sending a malformed POST request and particular configuration parameters are set."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:48:09.163Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37036",
    "datePublished": "2024-06-12T16:48:09.163Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.996Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-37036",
      "date": "2026-09-15",
      "epss": "0.00531",
      "percentile": "0.43404"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:sage_rtu_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"c3414-500-s02k5_p8\", \"matchCriteriaId\": \"F3A29B28-4959-4156-B77A-5D38B896029B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"02E606BD-92F8-4396-AD13-666D76E1E34D\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"97E29CCC-4E21-411E-80DD-545A66E9B042\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"66759867-027F-4FA6-ABA6-BFDEE49E8F8D\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AA561E2A-4787-48D7-ABBB-26D0D7D24E6F\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"453696F2-0F4C-4000-A438-F814D0FC3504\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6462B366-8F9F-49D6-939A-E73C1D5A707C\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\\nwhen sending a malformed POST request and particular configuration parameters are set.\"}, {\"lang\": \"es\", \"value\": \"CWE-787: Existe una vulnerabilidad de escritura fuera de los l\\u00edmites que podr\\u00eda provocar una omisi\\u00f3n de autenticaci\\u00f3n al enviar una solicitud POST con formato incorrecto y se establecen par\\u00e1metros de configuraci\\u00f3n particulares.\"}]",
      "id": "CVE-2024-37036",
      "lastModified": "2024-11-21T09:23:05.510",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
      "published": "2024-06-12T17:15:50.637",
      "references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-37036\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2024-06-12T17:15:50.637\",\"lastModified\":\"2026-06-17T07:37:38.767\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\\nwhen sending a malformed POST request and particular configuration parameters are set.\"},{\"lang\":\"es\",\"value\":\"CWE-787: Existe una vulnerabilidad de escritura fuera de los l\u00edmites que podr\u00eda provocar una omisi\u00f3n de autenticaci\u00f3n al enviar una solicitud POST con formato incorrecto y se establecen par\u00e1metros de configuraci\u00f3n particulares.\"}],\"affected\":[{\"source\":\"cybersecurity@se.com\",\"affectedData\":[{\"vendor\":\"Schneider Electric\",\"product\":\"Sage 1410\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"Versions C3414-500-S02K5_P8 and prior\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\"Sage 1430\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"Versions C3414-500-S02K5_P8 and prior\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\"Sage 1450\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"Versions C3414-500-S02K5_P8 and prior\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\"Sage 2400\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"Versions C3414-500-S02K5_P8 and prior\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\"Sage 3030 Magnum\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"Versions C3414-500-S02K5_P8 and prior\",\"status\":\"affected\"}]},{\"vendor\":\"Schneider Electric\",\"product\":\"Sage 4400\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"Versions C3414-500-S02K5_P8 and prior\",\"status\":\"affected\"}]}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"affectedData\":[{\"vendor\":\"schneider_electric\",\"product\":\"sage_4400_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:schneider_electric:sage_1410_firmware:*:*:*:*:*:*:*:*\",\"cpe:2.3:o:schneider_electric:sage_1430_firmware:*:*:*:*:*:*:*:*\",\"cpe:2.3:o:schneider_electric:sage_1450_firmware:*:*:*:*:*:*:*:*\",\"cpe:2.3:o:schneider_electric:sage_2400_firmware:*:*:*:*:*:*:*:*\",\"cpe:2.3:o:schneider_electric:sage_3030_magnum_firmware:*:*:*:*:*:*:*:*\",\"cpe:2.3:o:schneider_electric:sage_4400_firmware:*:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThanOrEqual\":\"C3414-500-S02K5_P8\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2024-06-12T17:43:17.841310Z\",\"id\":\"CVE-2024-37036\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"yes\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:sage_rtu_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"c3414-500-s02k5_p8\",\"matchCriteriaId\":\"F3A29B28-4959-4156-B77A-5D38B896029B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"02E606BD-92F8-4396-AD13-666D76E1E34D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"97E29CCC-4E21-411E-80DD-545A66E9B042\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66759867-027F-4FA6-ABA6-BFDEE49E8F8D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA561E2A-4787-48D7-ABBB-26D0D7D24E6F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"453696F2-0F4C-4000-A438-F814D0FC3504\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6462B366-8F9F-49D6-939A-E73C1D5A707C\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2025-05-28T20:29:17+00:00",
      "cve": "CVE-2024-37036",
      "id": "CVE-2024-37036",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-37036",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-37036.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T03:43:50.996Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-37036\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-06-12T17:43:17.841310Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:schneider_electric:sage_1410_firmware:*:*:*:*:*:*:*:*\", \"cpe:2.3:o:schneider_electric:sage_1430_firmware:*:*:*:*:*:*:*:*\", \"cpe:2.3:o:schneider_electric:sage_1450_firmware:*:*:*:*:*:*:*:*\", \"cpe:2.3:o:schneider_electric:sage_2400_firmware:*:*:*:*:*:*:*:*\", \"cpe:2.3:o:schneider_electric:sage_3030_magnum_firmware:*:*:*:*:*:*:*:*\", \"cpe:2.3:o:schneider_electric:sage_4400_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"schneider_electric\", \"product\": \"sage_4400_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"C3414-500-S02K5_P8\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-12T17:57:28.765Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Sage 1410\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 1430\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 1450\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 2400\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 3030 Magnum\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Sage 4400\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions C3414-500-S02K5_P8 and prior\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\\nwhen sending a malformed POST request and particular configuration parameters are set.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\\n\\nCWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\\nwhen sending a malformed POST request and particular configuration parameters are set.\\n\\n\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-787\", \"description\": \"CWE-787 Out-of-bounds Write\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2024-06-12T16:48:09.163Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-37036\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T03:43:50.996Z\", \"dateReserved\": \"2024-05-31T06:52:05.762Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2024-06-12T16:48:09.163Z\", \"assignerShortName\": \"schneider\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…