GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-4170 (GCVE-0-2024-4170)

Vulnerability from cvelistv5 – Published: 2024-04-25 13:00 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda 4G300 sub_429A30 stack-based overflow
Summary
A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-04-25 16:39 UTC
CWE
  • CWE-121 - Stack-based Buffer Overflow
References
URL Tags
https://vuldb.com/?id.261989 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261989 signaturepermissions-required
https://vuldb.com/?submit.318991 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… related
Impacted products
Vendor Product Version CPE status
Tenda 4G300 Affected: 1.01.42
guessed Create a notification for this product.
tenda 4g300_firmware Affected: 1.01.42
    cpe:2.3:o:tenda:4g300_firmware:1.01.42:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:4g300_firmware:1.01.42:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "4g300_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.01.42"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4170",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-25T16:39:52.948205Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:53:39.795Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.721Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261989 | Tenda 4G300 sub_429A30 stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261989"
          },
          {
            "name": "VDB-261989 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261989"
          },
          {
            "name": "Submit #318991 | Tenda 4G300 V1.01.42 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.318991"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "4G300",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.01.42"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda 4G300 1.01.42 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion sub_429A30. Mit der Manipulation des Arguments list1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T13:00:06.597Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261989 | Tenda 4G300 sub_429A30 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261989"
        },
        {
          "name": "VDB-261989 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261989"
        },
        {
          "name": "Submit #318991 | Tenda 4G300 V1.01.42 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.318991"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-25T06:46:56.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda 4G300 sub_429A30 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4170",
    "datePublished": "2024-04-25T13:00:06.597Z",
    "dateReserved": "2024-04-25T04:41:38.465Z",
    "dateUpdated": "2024-08-01T20:33:52.721Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-4170",
      "date": "2026-09-17",
      "epss": "0.01683",
      "percentile": "0.75853"
    },
    "fkie_nvd": {
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "es",
          "value": "Se encontr\u00f3 una vulnerabilidad en Tenda 4G300 1.01.42. Ha sido calificada como cr\u00edtica. Este problema afecta a la funci\u00f3n sub_429A30. La manipulaci\u00f3n del argumento list1 conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-261989. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
        }
      ],
      "id": "CVE-2024-4170",
      "lastModified": "2024-11-21T09:42:19.523",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 9.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "cna@vuldb.com",
            "type": "Secondary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      },
      "published": "2024-04-25T13:15:51.993",
      "references": [
        {
          "source": "cna@vuldb.com",
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
        },
        {
          "source": "cna@vuldb.com",
          "url": "https://vuldb.com/?ctiid.261989"
        },
        {
          "source": "cna@vuldb.com",
          "url": "https://vuldb.com/?id.261989"
        },
        {
          "source": "cna@vuldb.com",
          "url": "https://vuldb.com/?submit.318991"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://vuldb.com/?ctiid.261989"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://vuldb.com/?id.261989"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://vuldb.com/?submit.318991"
        }
      ],
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "4G300",
                "vendor": "Tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.01.42"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:4g300_firmware:1.01.42:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "4g300_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.01.42"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:4g300_firmware:1.01.42:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7A11C718-6F74-46FD-8C72-6E9FF1FA9FE4",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B8A63A3E-E6B1-42C8-ABA8-5E19777392B5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "es",
            "value": "Se encontr\u00f3 una vulnerabilidad en Tenda 4G300 1.01.42. Ha sido calificada como cr\u00edtica. Este problema afecta a la funci\u00f3n sub_429A30. La manipulaci\u00f3n del argumento list1 conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-261989. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
          }
        ],
        "id": "CVE-2024-4170",
        "lastModified": "2026-06-17T08:01:15.893",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-4170",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-25T16:39:52.948205Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-04-25T13:15:51.993",
        "references": [
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?ctiid.261989"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?id.261989"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?submit.318991"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Permissions Required",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?ctiid.261989"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?id.261989"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?submit.318991"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T21:17:59+00:00",
      "cve": "CVE-2024-4170",
      "id": "CVE-2024-4170",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Tenda 4G300 sub_429A30 stack-based overflow",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-4170.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:33:52.721Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-261989 | Tenda 4G300 sub_429A30 stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.261989"
              },
              {
                "name": "VDB-261989 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.261989"
              },
              {
                "name": "Submit #318991 | Tenda 4G300 V1.01.42 Buffer Overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.318991"
              },
              {
                "tags": [
                  "related",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:4g300_firmware:1.01.42:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "4g300_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.01.42"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4170",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-25T16:39:52.948205Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-04-25T16:39:43.247Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "4G300",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.01.42"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda 4G300 1.01.42 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion sub_429A30. Mit der Manipulation des Arguments list1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-25T13:00:06.597Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-261989 | Tenda 4G300 sub_429A30 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.261989"
            },
            {
              "name": "VDB-261989 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.261989"
            },
            {
              "name": "Submit #318991 | Tenda 4G300 V1.01.42 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.318991"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_429A30.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-04-25T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-04-25T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-04-25T06:46:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda 4G300 sub_429A30 stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-4170",
        "datePublished": "2024-04-25T13:00:06.597Z",
        "dateReserved": "2024-04-25T04:41:38.465Z",
        "dateUpdated": "2024-08-01T20:33:52.721Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…