Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2023-44120 (GCVE-0-2023-44120)
Vulnerability from cvelistv5
- CWE-732 - Incorrect Permission Assignment for Critical Resource
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | Spectrum Power 7 |
Version: All versions < V23Q4 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.225Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-44120",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-22T20:23:10.458980Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-14T15:24:09.445Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Spectrum Power 7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V23Q4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:59:44.755Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-44120",
"datePublished": "2024-01-09T09:59:44.755Z",
"dateReserved": "2023-09-25T10:24:56.157Z",
"dateUpdated": "2024-11-14T15:24:09.445Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2023-44120\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-01-09T10:15:15.613\",\"lastModified\":\"2024-11-21T08:25:17.160\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Spectrum Power 7 (todas las versiones \"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:spectrum_power_7:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"23q4\",\"matchCriteriaId\":\"FC8FAB94-415B-4D17-9270-EAE1D19F6CFC\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T19:59:51.225Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-44120\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-01-22T20:23:10.458980Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-14T15:23:24.721Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Spectrum Power 7\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V23Q4\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-732\", \"description\": \"CWE-732: Incorrect Permission Assignment for Critical Resource\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-01-09T09:59:44.755Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-44120\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-14T15:24:09.445Z\", \"dateReserved\": \"2023-09-25T10:24:56.157Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2024-01-09T09:59:44.755Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
cnvd-2024-01394
Vulnerability from cnvd
厂商已发布了漏洞修复程序,请及时关注更新: https://cert-portal.siemens.com/productcert/html/ssa-786191.html
| Name | Siemens Spectrum Power 7 <23Q4 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2023-44120"
}
},
"description": "Spectrum Power 7\u4e3a\u63a7\u5236\u548c\u76d1\u63a7\u7cfb\u7edf\u63d0\u4f9bSCADA\u3001\u901a\u4fe1\u548c\u6570\u636e\u5efa\u6a21\u7684\u57fa\u672c\u7ec4\u4ef6\u3002\u53ef\u4ee5\u6dfb\u52a0\u5e94\u7528\u7a0b\u5e8f\u5957\u4ef6\u6765\u4f18\u5316\u6240\u6709\u80fd\u6e90\u7ba1\u7406\u9886\u57df\u7684\u7f51\u7edc\u548c\u53d1\u7535\u7ba1\u7406\u3002\n\nSiemens Spectrum Power 7\u5b58\u5728\u5173\u952e\u8d44\u6e90\u7684\u6743\u9650\u5206\u914d\u9519\u8bef\u6f0f\u6d1e\uff0c\u7ecf\u8fc7\u8eab\u4efd\u9a8c\u8bc1\u7684\u672c\u5730\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u6ce8\u5165\u4efb\u610f\u4ee3\u7801\u5e76\u83b7\u53d6\u6839\u8bbf\u95ee\u6743\u9650\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-786191.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2024-01394",
"openTime": "2024-01-10",
"patchDescription": "Spectrum Power 7\u4e3a\u63a7\u5236\u548c\u76d1\u63a7\u7cfb\u7edf\u63d0\u4f9bSCADA\u3001\u901a\u4fe1\u548c\u6570\u636e\u5efa\u6a21\u7684\u57fa\u672c\u7ec4\u4ef6\u3002\u53ef\u4ee5\u6dfb\u52a0\u5e94\u7528\u7a0b\u5e8f\u5957\u4ef6\u6765\u4f18\u5316\u6240\u6709\u80fd\u6e90\u7ba1\u7406\u9886\u57df\u7684\u7f51\u7edc\u548c\u53d1\u7535\u7ba1\u7406\u3002\r\n\r\nSiemens Spectrum Power 7\u5b58\u5728\u5173\u952e\u8d44\u6e90\u7684\u6743\u9650\u5206\u914d\u9519\u8bef\u6f0f\u6d1e\uff0c\u7ecf\u8fc7\u8eab\u4efd\u9a8c\u8bc1\u7684\u672c\u5730\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u6ce8\u5165\u4efb\u610f\u4ee3\u7801\u5e76\u83b7\u53d6\u6839\u8bbf\u95ee\u6743\u9650\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens Spectrum Power 7\u5173\u952e\u8d44\u6e90\u7684\u6743\u9650\u5206\u914d\u9519\u8bef\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Siemens Spectrum Power 7 \u003c23Q4"
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-786191.html",
"serverity": "\u4e2d",
"submitTime": "2024-01-10",
"title": "Siemens Spectrum Power 7\u5173\u952e\u8d44\u6e90\u7684\u6743\u9650\u5206\u914d\u9519\u8bef\u6f0f\u6d1e"
}
icsa-24-011-07
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Spectrum Power 7 is affected by a vulnerability that could allow an authenticated local attacker to inject arbitrary code and gain root access.\n\nSiemens has released an update for Spectrum Power 7 and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-786191.json"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-786191.html"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-786191.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-011-07 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-011-07.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-011-07 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-011-07"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Spectrum Power 7",
"tracking": {
"current_release_date": "2024-01-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-24-011-07",
"initial_release_date": "2024-01-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2024-01-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV23Q4",
"product": {
"name": "Spectrum Power 7",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Spectrum Power 7"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-44120",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V23Q4 or later version",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-44120"
}
]
}
ICSA-24-011-07
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Spectrum Power 7 is affected by a vulnerability that could allow an authenticated local attacker to inject arbitrary code and gain root access.\n\nSiemens has released an update for Spectrum Power 7 and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-786191.json"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-786191.html"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-786191.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-011-07 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-011-07.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-24-011-07 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-011-07"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Spectrum Power 7",
"tracking": {
"current_release_date": "2024-01-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-24-011-07",
"initial_release_date": "2024-01-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2024-01-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV23Q4",
"product": {
"name": "Spectrum Power 7",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Spectrum Power 7"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-44120",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V23Q4 or later version",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-44120"
}
]
}
ghsa-hv6m-386r-hchx
Vulnerability from github
A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q4). The affected product's sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.
{
"affected": [],
"aliases": [
"CVE-2023-44120"
],
"database_specific": {
"cwe_ids": [
"CWE-732"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2024-01-09T10:15:15Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.",
"id": "GHSA-hv6m-386r-hchx",
"modified": "2024-01-09T12:30:35Z",
"published": "2024-01-09T12:30:35Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-44120"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
fkie_cve-2023-44120
Vulnerability from fkie_nvd
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | spectrum_power_7 | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:spectrum_power_7:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FC8FAB94-415B-4D17-9270-EAE1D19F6CFC",
"versionEndExcluding": "23q4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Spectrum Power 7 (todas las versiones "
}
],
"id": "CVE-2023-44120",
"lastModified": "2024-11-21T08:25:17.160",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Primary"
}
]
},
"published": "2024-01-09T10:15:15.613",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
CERTFR-2024-AVI-0014
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | Spectrum Power 7 versions antérieures à V23Q4 | ||
| Siemens | N/A | CP-8050 MASTER MODULE (6MF2805-0AA00) versions antérieures à CPCI85 V05.20 | ||
| Siemens | N/A | Teamcenter Visualization versions V14.2 antérieures à V14.2.0.9 | ||
| Siemens | N/A | JT2Go versions antérieures à V14.3.0.6 | ||
| Siemens | N/A | Teamcenter Visualization versions V14.1 antérieures à V14.1.0.12 | ||
| Siemens | N/A | SIMATIC IPC647E avec maxView Storage Manager versions antérieures à V4.14.00.26068 sur Windows | ||
| Siemens | N/A | SIMATIC IPC847E avec maxView Storage Manager versions antérieures à V4.14.00.26068 sur Windows | ||
| Siemens | N/A | SIMATIC CN 4100 versions antérieures à V2.7 | ||
| Siemens | N/A | SIMATIC IPC1047E avec maxView Storage Manager versions antérieures à V4.14.00.26068 sur Windows | ||
| Siemens | N/A | CP-8031 MASTER MODULE (6MF2803-1AA00) versions antérieures à CPCI85 V05.20 | ||
| Siemens | N/A | Teamcenter Visualization versions V14.3 antérieures à V14.3.0.6 | ||
| Siemens | N/A | Teamcenter Visualization versions V13.3 antérieures à V13.3.0.13 | ||
| Siemens | N/A | Solid Edge SE2023 versions antérieures à V223.0 Update 10 |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Spectrum Power 7 versions ant\u00e9rieures \u00e0 V23Q4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8050 MASTER MODULE (6MF2805-0AA00) versions ant\u00e9rieures \u00e0 CPCI85 V05.20",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions V14.2 ant\u00e9rieures \u00e0 V14.2.0.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 V14.3.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions V14.1 ant\u00e9rieures \u00e0 V14.1.0.12",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC647E avec maxView Storage Manager versions ant\u00e9rieures \u00e0 V4.14.00.26068 sur Windows",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC847E avec maxView Storage Manager versions ant\u00e9rieures \u00e0 V4.14.00.26068 sur Windows",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CN 4100 versions ant\u00e9rieures \u00e0 V2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC1047E avec maxView Storage Manager versions ant\u00e9rieures \u00e0 V4.14.00.26068 sur Windows",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8031 MASTER MODULE (6MF2803-1AA00) versions ant\u00e9rieures \u00e0 CPCI85 V05.20",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions V14.3 ant\u00e9rieures \u00e0 V14.3.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions V13.3 ant\u00e9rieures \u00e0 V13.3.0.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2023 versions ant\u00e9rieures \u00e0 V223.0 Update 10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-49252",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49252"
},
{
"name": "CVE-2023-49123",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49123"
},
{
"name": "CVE-2023-42797",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-42797"
},
{
"name": "CVE-2023-49132",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49132"
},
{
"name": "CVE-2023-51744",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51744"
},
{
"name": "CVE-2023-49251",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49251"
},
{
"name": "CVE-2023-51438",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51438"
},
{
"name": "CVE-2023-49122",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49122"
},
{
"name": "CVE-2023-51746",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51746"
},
{
"name": "CVE-2023-51439",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51439"
},
{
"name": "CVE-2023-51745",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-51745"
},
{
"name": "CVE-2023-49124",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49124"
},
{
"name": "CVE-2023-49130",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49130"
},
{
"name": "CVE-2023-49131",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49131"
},
{
"name": "CVE-2023-49129",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49129"
},
{
"name": "CVE-2023-44120",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44120"
},
{
"name": "CVE-2023-49621",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49621"
},
{
"name": "CVE-2023-49126",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49126"
},
{
"name": "CVE-2023-49121",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49121"
},
{
"name": "CVE-2023-49127",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49127"
},
{
"name": "CVE-2023-49128",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49128"
}
],
"initial_release_date": "2024-01-09T00:00:00",
"last_revision_date": "2024-01-09T00:00:00",
"links": [],
"reference": "CERTFR-2024-AVI-0014",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-01-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-777015 du 09 janvier 2024",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-777015.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-794653 du 09 janvier 2024",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794653.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-583634 du 09 janvier 2024",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-583634.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-702935 du 09 janvier 2024",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-702935.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-589891 du 09 janvier 2024",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-589891.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-786191 du 09 janvier 2024",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-786191.html"
}
]
}
var-202401-0199
Vulnerability from variot
A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q4). The affected product's sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202401-0199",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "spectrum power 7",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "23q4"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-44120"
}
]
},
"cve": "CVE-2023-44120",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2023-44120",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2023-44120",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-44120"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-44120"
}
],
"trust": 1.0
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "SIEMENS",
"id": "SSA-786191",
"trust": 1.0
},
{
"db": "NVD",
"id": "CVE-2023-44120",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-44120"
}
]
},
"id": "VAR-202401-0199",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.4743083
},
"last_update_date": "2024-08-14T15:10:23.200000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-732",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-44120"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-44120"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-44120"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-09T10:15:15.613000",
"db": "NVD",
"id": "CVE-2023-44120"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-16T15:36:11.773000",
"db": "NVD",
"id": "CVE-2023-44120"
}
]
}
}
SSA-786191
Vulnerability from csaf_siemens
Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Spectrum Power 7 is affected by a vulnerability that could allow an authenticated local attacker to inject arbitrary code and gain root access.\n\nSiemens has released an update for Spectrum Power 7 and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-786191.html"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-786191.json"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-786191.txt"
}
],
"title": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7",
"tracking": {
"current_release_date": "2024-01-09T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-786191",
"initial_release_date": "2024-01-09T00:00:00Z",
"revision_history": [
{
"date": "2024-01-09T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V23Q4",
"product": {
"name": "Spectrum Power 7",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Spectrum Power 7"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-44120",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V23Q4 or later version",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-44120"
}
]
}
ssa-786191
Vulnerability from csaf_siemens
Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Spectrum Power 7 is affected by a vulnerability that could allow an authenticated local attacker to inject arbitrary code and gain root access.\n\nSiemens has released an update for Spectrum Power 7 and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-786191.html"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-786191.json"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
},
{
"category": "self",
"summary": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-786191.txt"
}
],
"title": "SSA-786191: Local Privilege Escalation Vulnerability in Spectrum Power 7",
"tracking": {
"current_release_date": "2024-01-09T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-786191",
"initial_release_date": "2024-01-09T00:00:00Z",
"revision_history": [
{
"date": "2024-01-09T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V23Q4",
"product": {
"name": "Spectrum Power 7",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Spectrum Power 7"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-44120",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V23Q4 or later version",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2023-44120"
}
]
}
gsd-2023-44120
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2023-44120",
"id": "GSD-2023-44120"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-44120"
],
"details": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.",
"id": "GSD-2023-44120",
"modified": "2023-12-13T01:20:39.053391Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2023-44120",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Spectrum Power 7",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V23Q4"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-732",
"lang": "eng",
"value": "CWE-732: Incorrect Permission Assignment for Critical Resource"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
}
]
}
},
"nvd.nist.gov": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:spectrum_power_7:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FC8FAB94-415B-4D17-9270-EAE1D19F6CFC",
"versionEndExcluding": "23q4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Spectrum Power 7 (todas las versiones "
}
],
"id": "CVE-2023-44120",
"lastModified": "2024-01-16T15:36:11.773",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Primary"
}
]
},
"published": "2024-01-09T10:15:15.613",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
}
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.