Vulnerability from cvelistv5 – Published: 2023-02-08 19:21 – Updated: 2026-05-18 14:37
VLAI
Title
SQL Injection in Smartpower Web
Summary
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection. This issue affects Smartpower Web: before 23.01.01.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-24 19:12 UTC
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
References
Impacted products
Vendor Product Version CPE status
Group Arge Energy and Control Systems Smartpower Web Affected: 0 , < 23.01.01 (custom)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:01:31.531Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-45090",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-24T19:12:09.543713Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-24T19:38:34.511Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Smartpower Web",
          "vendor": "Group Arge Energy and Control Systems",
          "versions": [
            {
              "lessThan": "23.01.01",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Furkan KUTLUCA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
            }
          ],
          "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-18T14:37:25.895Z",
        "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "shortName": "TR-CERT"
      },
      "references": [
        {
          "tags": [
            "government-resource",
            "broken-link"
          ],
          "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Update the software to \u0026gt;= 23.01.01"
            }
          ],
          "value": "Update the software to \u003e= 23.01.01"
        }
      ],
      "source": {
        "advisory": "TR-23-0066",
        "defect": [
          "TR-23-0066"
        ],
        "discovery": "EXTERNAL"
      },
      "timeline": [
        {
          "lang": "en",
          "time": "2022-11-08T14:44:00.000Z",
          "value": "Vulnerability detected"
        },
        {
          "lang": "en",
          "time": "2022-11-09T10:35:00.000Z",
          "value": "CVE ID reservation"
        },
        {
          "lang": "en",
          "time": "2022-11-09T12:00:00.000Z",
          "value": "Vendor informed"
        },
        {
          "lang": "en",
          "time": "2023-01-01T10:00:00.000Z",
          "value": "Patch published by vendor"
        },
        {
          "lang": "en",
          "time": "2023-02-08T13:00:00.000Z",
          "value": "Government advisory published"
        },
        {
          "lang": "en",
          "time": "2023-02-08T14:50:00.000Z",
          "value": "CVE published"
        }
      ],
      "title": "SQL Injection in Smartpower Web",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
    "assignerShortName": "TR-CERT",
    "cveId": "CVE-2022-45090",
    "datePublished": "2023-02-08T19:21:32.092Z",
    "dateReserved": "2022-11-09T13:35:23.470Z",
    "dateUpdated": "2026-05-18T14:37:25.895Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-45090",
      "date": "2026-09-17",
      "epss": "0.00645",
      "percentile": "0.49307"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:gruparge:smartpower_web:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6D0C38E0-4799-4948-9E46-7142D80B2D92",
                  "versionEndExcluding": "23.01.01",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.This issue affects Smartpower Web: before 23.01.01.\n\n"
        }
      ],
      "id": "CVE-2022-45090",
      "lastModified": "2024-11-21T07:28:45.677",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "iletisim@usom.gov.tr",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2023-02-12T04:15:16.790",
      "references": [
        {
          "source": "iletisim@usom.gov.tr",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
        }
      ],
      "sourceIdentifier": "iletisim@usom.gov.tr",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-89"
            }
          ],
          "source": "iletisim@usom.gov.tr",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-89"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Smartpower Web",
                "vendor": "Group Arge Energy and Control Systems",
                "versions": [
                  {
                    "lessThan": "23.01.01",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "iletisim@usom.gov.tr"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:gruparge:smartpower_web:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6D0C38E0-4799-4948-9E46-7142D80B2D92",
                    "versionEndExcluding": "23.01.01",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
          }
        ],
        "id": "CVE-2022-45090",
        "lastModified": "2026-06-17T05:09:20.327",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "iletisim@usom.gov.tr",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2022-45090",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-24T19:12:09.543713Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2023-02-12T04:15:16.790",
        "references": [
          {
            "source": "iletisim@usom.gov.tr",
            "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
          },
          {
            "source": "iletisim@usom.gov.tr",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
          }
        ],
        "sourceIdentifier": "iletisim@usom.gov.tr",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-89"
              }
            ],
            "source": "iletisim@usom.gov.tr",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-89"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-05-18T19:58:22+00:00",
      "cve": "CVE-2022-45090",
      "id": "CVE-2022-45090",
      "initial_release_date": "2022-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "SQL Injection in Smartpower Web",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-45090.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.531Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45090",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T19:12:09.543713Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T19:12:04.607Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower Web",
              "vendor": "Group Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThan": "23.01.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Furkan KUTLUCA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
                }
              ],
              "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-18T14:37:25.895Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update the software to \u0026gt;= 23.01.01"
                }
              ],
              "value": "Update the software to \u003e= 23.01.01"
            }
          ],
          "source": {
            "advisory": "TR-23-0066",
            "defect": [
              "TR-23-0066"
            ],
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2022-11-08T14:44:00.000Z",
              "value": "Vulnerability detected"
            },
            {
              "lang": "en",
              "time": "2022-11-09T10:35:00.000Z",
              "value": "CVE ID reservation"
            },
            {
              "lang": "en",
              "time": "2022-11-09T12:00:00.000Z",
              "value": "Vendor informed"
            },
            {
              "lang": "en",
              "time": "2023-01-01T10:00:00.000Z",
              "value": "Patch published by vendor"
            },
            {
              "lang": "en",
              "time": "2023-02-08T13:00:00.000Z",
              "value": "Government advisory published"
            },
            {
              "lang": "en",
              "time": "2023-02-08T14:50:00.000Z",
              "value": "CVE published"
            }
          ],
          "title": "SQL Injection in Smartpower Web",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2022-45090",
        "datePublished": "2023-02-08T19:21:32.092Z",
        "dateReserved": "2022-11-09T13:35:23.470Z",
        "dateUpdated": "2026-05-18T14:37:25.895Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…