Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-40967
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06 | Mitigation, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06 | Mitigation, Third Party Advisory, US Government Resource |
Vendor | Product | Version | |
---|---|---|---|
▼ | Delta Electronics | DIAEnergie |
Version: All < v1.9.01.002 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:28:42.933Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DIAEnergie", "vendor": "Delta Electronics", "versions": [ { "lessThan": "v1.9.01.002", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Michael Heinzl reported these vulnerabilities to CISA." } ], "datePublic": "2022-10-25T00:00:00", "descriptions": [ { "lang": "en", "value": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-89", "description": "CWE-89 SQL Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-27T00:00:00", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06" } ], "solutions": [ { "lang": "en", "value": "Delta did not publicly release v1.9.01.002. Users are encouraged to contact Delta front-end sales or agents to get this updated version." } ], "source": { "advisory": "ICSA-22-298-06", "discovery": "EXTERNAL" }, "title": "Delta Electronics DIAEnergie", "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-40967", "datePublished": "2022-10-27T20:15:38.073089Z", "dateReserved": "2022-09-29T00:00:00", "dateUpdated": "2024-09-16T18:03:59.370Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-40967\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-10-27T21:15:14.650\",\"lastModified\":\"2024-11-21T07:22:19.503\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.\"},{\"lang\":\"es\",\"value\":\"El producto afectado DIAEnergie (versiones anteriores a la v1.9.01.002) es vulnerable a una inyecci\u00f3n SQL que existe en CheckIoTHubNameExisted. Un atacante autenticado con pocos privilegios podr\u00eda aprovechar este problema para inyectar consultas SQL arbitrarias.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.9.01.002\",\"matchCriteriaId\":\"AAE6117B-37DC-4B60-8ECF-F1BF40F992BF\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
ghsa-9m4h-cwgq-6cq2
Vulnerability from github
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
{ "affected": [], "aliases": [ "CVE-2022-40967" ], "database_specific": { "cwe_ids": [ "CWE-89" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-10-27T21:15:00Z", "severity": "HIGH" }, "details": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.", "id": "GHSA-9m4h-cwgq-6cq2", "modified": "2022-10-28T19:00:30Z", "published": "2022-10-28T12:00:35Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-40967" }, { "type": "WEB", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
gsd-2022-40967
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-40967", "id": "GSD-2022-40967" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-40967" ], "details": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.", "id": "GSD-2022-40967", "modified": "2023-12-13T01:19:31.452053Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2022-10-25T17:00:00.000Z", "ID": "CVE-2022-40967", "STATE": "PUBLIC", "TITLE": "Delta Electronics DIAEnergie" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DIAEnergie", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "All", "version_value": "v1.9.01.002" } ] } } ] }, "vendor_name": "Delta Electronics" } ] } }, "credit": [ { "lang": "eng", "value": "Michael Heinzl reported these vulnerabilities to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-89 SQL Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06" } ] }, "solution": [ { "lang": "eng", "value": "Delta did not publicly release v1.9.01.002. Users are encouraged to contact Delta front-end sales or agents to get this updated version." } ], "source": { "advisory": "ICSA-22-298-06", "discovery": "EXTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.9.01.002", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-40967" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-89" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06", "refsource": "MISC", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2022-10-28T18:35Z", "publishedDate": "2022-10-27T21:15Z" } } }
icsa-22-298-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael Heinzl" ], "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "This updated advisory is a follow-up to the original advisory titled ICSA-22-298-06 Delta Electronics DIAEnergie (Update A) that was published November 10, 2022, to the ICS webpage at www.cisa.gov/uscert.", "title": "Update Summary" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to inject arbitrary code to retrieve and modify database contents and execute system commands.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Taiwan", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-298-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-298-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-298-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-298-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" } ], "title": "Delta Electronics DIAEnergie", "tracking": { "current_release_date": "2023-02-16T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-298-06", "initial_release_date": "2022-11-10T00:00:00.000000Z", "revision_history": [ { "date": "2022-11-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Delta Electronics DIAEnergie (Update B)" }, { "date": "2023-02-16T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "Delta Electronics DIAEnergie (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 1.9.01.002", "product": { "name": "DIAEnergie - DIAEnergie versions prior to v1.9.01.002", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "DIAEnergie" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 1.9.02.001", "product": { "name": "DIAEnergie - DIAEnergie versions prior to v1.9.02.001", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "DIAEnergie" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 1.9.03.001", "product": { "name": "DIAEnergie: \u003c 1.9.03.001", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "DIAEnergie" } ], "category": "vendor", "name": "Delta Electronics" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-41701", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API. CVE-2022-41701 has been assigned to this vulnerability. A CVSS v3 base score of 8.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-41701" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-40965", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API. CVE-2022-40965 has been assigned to this vulnerability. A CVSS v3 base score of 8.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-40965" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-41555", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting API. CVE-2022-41555 has been assigned to this vulnerability. A CVSS v3 base score of 8.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-41555" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-41702", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API. CVE-2022-41702 has been assigned to this vulnerability. A CVSS v3 base score of 8.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-41702" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-41651", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API. CVE-2022-41651 has been assigned to this vulnerability. A CVSS v3 base score of 8.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-41651" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-40967", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. CVE-2022-40967 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-40967" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-41133", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. CVE-2022-41133 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-41133" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-41773", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. CVE-2022-41773 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-41773" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-41775", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.02.001) is vulnerable to a SQL injection that exists in Handler_CFG.ashx. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. CVE-2022-41775 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-41775" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-43447", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.02.001) is vulnerable to a SQL injection that exists in AM_EBillAnalysis.aspx. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. CVE-2022-43447 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-43447" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-43506", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.02.001) is vulnerable to a SQL injection that exists in HandlerTag_KID.ashx. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. CVE-2022-43506 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-43506" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-43457", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.02.001) is vulnerable to a SQL injection that exists in HandlerPage_KID.ashx. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. CVE-2022-43457 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-43457" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-43452", "cwe": { "id": "CWE-89", "name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.02.001) is vulnerable to a SQL injection that exists in FtyInfoSetting.aspx. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. CVE-2022-43452 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-43452" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2023-0822", "cwe": { "id": "CWE-285", "name": "Improper Authorization" }, "notes": [ { "category": "summary", "text": "The affected product DIAEnergie (versions prior to v1.9.03.001) contains improper authorization, which could allow an unauthorized user to bypass authorization and access privileged functionality. CVE-2023-0822 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-0822" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Delta did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities. Users are encouraged to contact Delta to receive these updates.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] } ] }
var-202210-1863
Vulnerability from variot
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. Delta Electronics, INC. of DIAEnergie for, SQL There is an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Delta Electronics DIAEnergie is an industrial energy management system for monitoring and analyzing energy consumption in real time, calculating energy consumption and load characteristics, optimizing equipment performance, improving production processes and maximizing energy efficiency
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-1863", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "diaenergie", "scope": "lt", "trust": 1.0, "vendor": "deltaww", "version": "1.9.01.002" }, { "model": "diaenergie", "scope": "eq", "trust": 0.8, "vendor": "delta", "version": "1.9.01.002" }, { "model": "diaenergie", "scope": null, "trust": 0.8, "vendor": "delta", "version": null }, { "model": "diaenergie", "scope": "eq", "trust": 0.8, "vendor": "delta", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-019031" }, { "db": "NVD", "id": "CVE-2022-40967" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.9.01.002", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-40967" } ] }, "cve": "CVE-2022-40967", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-40967", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-40967", "trust": 1.8, "value": "HIGH" }, { "author": "ics-cert@hq.dhs.gov", "id": "CVE-2022-40967", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202210-2391", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-019031" }, { "db": "NVD", "id": "CVE-2022-40967" }, { "db": "NVD", "id": "CVE-2022-40967" }, { "db": "CNNVD", "id": "CNNVD-202210-2391" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. Delta Electronics, INC. of DIAEnergie for, SQL There is an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Delta Electronics DIAEnergie is an industrial energy management system for monitoring and analyzing energy consumption in real time, calculating energy consumption and load characteristics, optimizing equipment performance, improving production processes and maximizing energy efficiency", "sources": [ { "db": "NVD", "id": "CVE-2022-40967" }, { "db": "JVNDB", "id": "JVNDB-2022-019031" }, { "db": "CNNVD", "id": "CNNVD-202210-2391" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-40967", "trust": 3.2 }, { "db": "ICS CERT", "id": "ICSA-22-298-06", "trust": 2.4 }, { "db": "JVN", "id": "JVNVU91874962", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-019031", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202210-2391", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-019031" }, { "db": "NVD", "id": "CVE-2022-40967" }, { "db": "CNNVD", "id": "CNNVD-202210-2391" } ] }, "id": "VAR-202210-1863", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 1.0 }, "last_update_date": "2023-12-18T11:55:27.707000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-89", "trust": 1.0 }, { "problemtype": "SQL injection (CWE-89) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-019031" }, { "db": "NVD", "id": "CVE-2022-40967" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91874962/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-40967" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-40967/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-019031" }, { "db": "NVD", "id": "CVE-2022-40967" }, { "db": "CNNVD", "id": "CNNVD-202210-2391" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2022-019031" }, { "db": "NVD", "id": "CVE-2022-40967" }, { "db": "CNNVD", "id": "CNNVD-202210-2391" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-019031" }, { "date": "2022-10-27T21:15:14.650000", "db": "NVD", "id": "CVE-2022-40967" }, { "date": "2022-10-27T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-2391" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-24T05:51:00", "db": "JVNDB", "id": "JVNDB-2022-019031" }, { "date": "2022-10-28T18:35:49.140000", "db": "NVD", "id": "CVE-2022-40967" }, { "date": "2022-10-31T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-2391" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-2391" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Delta\u00a0Electronics,\u00a0INC.\u00a0 of \u00a0DIAEnergie\u00a0 In \u00a0SQL\u00a0 Injection vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-019031" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "SQL injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-2391" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.