CVE-2022-34821 (GCVE-0-2022-34821)
Vulnerability from cvelistv5 – Published: 2022-07-12 00:00 – Updated: 2025-04-21 13:52
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-18 15:23 UTC
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
62 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | RUGGEDCOM RM1224 LTE(4G) NAM |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M804PB |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M812-1 ADSL-Router |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M816-1 ADSL-Router |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M826-2 SHDSL-Router |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M874-2 |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M874-3 |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M876-3 |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M876-3 (ROK) |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M876-4 |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M876-4 (EU) |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE M876-4 (NAM) |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE MUM853-1 (EU) |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE MUM856-1 (EU) |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE MUM856-1 (RoW) |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE S615 EEC LAN-Router |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE S615 LAN-Router |
Affected:
0 , < V7.2
(custom)
|
guessed | |
| Siemens | SCALANCE SC622-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC622-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC626-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC626-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC632-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC632-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC636-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC636-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC642-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC642-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC646-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC646-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAB762-1 |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM763-1 |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM763-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM763-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 EEC |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 EEC (ME) |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 EEC (US) |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUB762-1 |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUB762-1 iFeatures |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUM763-1 |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUM763-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUM766-1 |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUM766-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUM766-1 (USA) |
Affected:
0 , < V3.0.0
(custom)
|
guessed | |
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
All versions < V3.3.46
|
guessed | |
| Siemens | SIMATIC CP 1243-1 |
Affected:
All versions < V3.3.46
|
guessed | |
| Siemens | SIMATIC CP 1243-7 LTE EU |
Affected:
All versions < V3.3.46
|
guessed | |
| Siemens | SIMATIC CP 1243-7 LTE US |
Affected:
All versions < V3.3.46
|
guessed | |
| Siemens | SIMATIC CP 1243-8 IRC |
Affected:
All versions < V3.3.46
|
guessed | |
| Siemens | SIMATIC CP 1542SP-1 IRC |
Affected:
V2.0 , < V2.2.28
(custom)
|
guessed | |
| Siemens | SIMATIC CP 1543-1 |
Affected:
All versions < V3.0.22
|
guessed | |
| Siemens | SIMATIC CP 1543SP-1 |
Affected:
V2.0 , < V2.2.28
(custom)
|
guessed | |
| Siemens | SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL |
Affected:
V2.0 , < V2.2.28
(custom)
|
guessed | |
| Siemens | SIPLUS ET 200SP CP 1543SP-1 ISEC |
Affected:
V2.0 , < V2.2.28
(custom)
|
guessed | |
| Siemens | SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL |
Affected:
V2.0 , < V2.2.28
(custom)
|
guessed | |
| Siemens | SIPLUS NET CP 1242-7 V2 |
Affected:
All versions < V3.3.46
|
guessed | |
| Siemens | SIPLUS NET CP 1543-1 |
Affected:
All versions < V3.0.22
|
guessed | |
| Siemens | SIPLUS S7-1200 CP 1243-1 |
Affected:
All versions < V3.3.46
|
guessed | |
| Siemens | SIPLUS S7-1200 CP 1243-1 RAIL |
Affected:
All versions < V3.3.46
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:22:10.733Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-34821",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:23:16.425380Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:52:26.030Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1 iFeatures",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.22"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1543-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.22"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:26:58.220Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-517377.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-34821",
"datePublished": "2022-07-12T00:00:00.000Z",
"dateReserved": "2022-06-29T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:52:26.030Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-34821",
"date": "2026-09-19",
"epss": "0.02358",
"percentile": "0.82989"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "840C5C25-1E34-42FA-8221-7232622C204F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE3D7928-8E1A-400E-B790-58D6F5938E3C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93D43BC6-EDE3-4EE1-9410-4717EB641AD0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "786F3FFD-87E4-45B9-A33C-BAE58379FF39",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1674851A-D8DC-47C5-9D63-2F1082CE0366",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFC6ACFD-8893-4EA3-976B-FAAF7240C5DB",
"versionEndExcluding": "3.0.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "78127221-D455-4145-9B84-A598A284D591",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23C55242-F638-415E-B683-EE1484770105",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07505420-ADE4-4409-AFCC-45BCBC995543",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C624BBC7-D8C5-4C2F-B56B-D59D55F013F8",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
"matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7FE26E32-47C0-4976-A23A-07C1AE318C35",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43CDCCE3-B8C0-44D4-A8A0-25C49A4EA240",
"versionEndExcluding": "3.0.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_net_cp_1543-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5D7AB0D5-FD3E-416A-975B-D212B3350433",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE EU (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE US (Todas las versiones anteriores a V3. 3.46), SIMATIC CP 1243-8 IRC (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1542SP-1 IRC (Todas las versiones posteriores o iguales a V2.0), SIMATIC CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIMATIC CP 1543SP-1 (Todas las versiones posteriores o iguales a V2. 0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (Todas las versiones posteriores o iguales a V2. 0), SIPLUS NET CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIPLUS NET CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIPLUS S7-1200 CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (Todas las versiones anteriores a V3.3.46). Al inyectar c\u00f3digo a opciones de configuraci\u00f3n espec\u00edficas para OpenVPN, un atacante podr\u00eda ejecutar c\u00f3digo arbitrario con privilegios elevados"
}
],
"id": "CVE-2022-34821",
"lastModified": "2025-01-14T11:15:10.343",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.0,
"impactScore": 6.0,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"automatable": "NOT_DEFINED",
"availabilityRequirements": "NOT_DEFINED",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityRequirements": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirements": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"recovery": "NOT_DEFINED",
"safety": "NOT_DEFINED",
"subsequentSystemAvailability": "HIGH",
"subsequentSystemConfidentiality": "HIGH",
"subsequentSystemIntegrity": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"vulnerableSystemAvailability": "HIGH",
"vulnerableSystemConfidentiality": "HIGH",
"vulnerableSystemIntegrity": "HIGH"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2022-07-12T10:15:12.393",
"references": [
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-517377.html"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1 iFeatures",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.22"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1543-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.22"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
}
],
"source": "productcert@siemens.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "840C5C25-1E34-42FA-8221-7232622C204F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE3D7928-8E1A-400E-B790-58D6F5938E3C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93D43BC6-EDE3-4EE1-9410-4717EB641AD0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "786F3FFD-87E4-45B9-A33C-BAE58379FF39",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1674851A-D8DC-47C5-9D63-2F1082CE0366",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFC6ACFD-8893-4EA3-976B-FAAF7240C5DB",
"versionEndExcluding": "3.0.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "78127221-D455-4145-9B84-A598A284D591",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23C55242-F638-415E-B683-EE1484770105",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07505420-ADE4-4409-AFCC-45BCBC995543",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C624BBC7-D8C5-4C2F-B56B-D59D55F013F8",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
"matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7FE26E32-47C0-4976-A23A-07C1AE318C35",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43CDCCE3-B8C0-44D4-A8A0-25C49A4EA240",
"versionEndExcluding": "3.0.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_net_cp_1543-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5D7AB0D5-FD3E-416A-975B-D212B3350433",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE EU (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE US (Todas las versiones anteriores a V3. 3.46), SIMATIC CP 1243-8 IRC (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1542SP-1 IRC (Todas las versiones posteriores o iguales a V2.0), SIMATIC CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIMATIC CP 1543SP-1 (Todas las versiones posteriores o iguales a V2. 0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (Todas las versiones posteriores o iguales a V2. 0), SIPLUS NET CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIPLUS NET CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIPLUS S7-1200 CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (Todas las versiones anteriores a V3.3.46). Al inyectar c\u00f3digo a opciones de configuraci\u00f3n espec\u00edficas para OpenVPN, un atacante podr\u00eda ejecutar c\u00f3digo arbitrario con privilegios elevados"
}
],
"id": "CVE-2022-34821",
"lastModified": "2026-09-03T01:15:22.797",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.0,
"impactScore": 6.0,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-34821",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:23:16.425380Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-07-12T10:15:12.393",
"references": [
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-517377.html"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-29T03:11:18+00:00",
"cve": "CVE-2022-34821",
"id": "CVE-2022-34821",
"initial_release_date": "2022-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2022-34821",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-34821.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:22:10.733Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-34821",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:23:16.425380Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T15:23:18.372Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1 iFeatures",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.22"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2.28",
"status": "affected",
"version": "V2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1543-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.22"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:26:58.220Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-517377.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-34821",
"datePublished": "2022-07-12T00:00:00.000Z",
"dateReserved": "2022-06-29T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:52:26.030Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…