CVE-2022-32516 (GCVE-0-2022-32516)
Vulnerability from cvelistv5 – Published: 2023-01-30 00:00 – Updated: 2025-02-05 20:08- CWE-352 - Cross-Site Request Forgery (CSRF)
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Conext™ ComBox |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:46:43.469Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-32516",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:55:08.252212Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:08:26.260Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Conext\u2122 ComBox",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"datePublic": "2022-06-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-30T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-32516",
"datePublished": "2023-01-30T00:00:00.000Z",
"dateReserved": "2022-06-07T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:08:26.260Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:conext_combox_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"570ACEDE-DE9F-4E19-AA0F-A6C864263D4B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:conext_combox:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6F2F9562-402D-4069-83C0-E5C5CE05F2AB\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\\u2122 ComBox (All Versions)\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad CWE-352: Cross Site Request Forgery (CSRF) que podr\\u00eda causar que las configuraciones del sistema se anulen y provoquen un bucle de reinicio cuando el producto sufre una Cross Site Request Forgery (CSRF) basada en POST. Productos afectados: Conext? ComBox (todas las versiones)\"}]",
"id": "CVE-2022-32516",
"lastModified": "2024-11-21T07:06:32.330",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}]}",
"published": "2023-01-30T23:15:10.170",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-352\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-32516\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-01-30T23:15:10.170\",\"lastModified\":\"2024-11-21T07:06:32.330\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions)\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad CWE-352: Cross Site Request Forgery (CSRF) que podr\u00eda causar que las configuraciones del sistema se anulen y provoquen un bucle de reinicio cuando el producto sufre una Cross Site Request Forgery (CSRF) basada en POST. Productos afectados: Conext? ComBox (todas las versiones)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:conext_combox_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"570ACEDE-DE9F-4E19-AA0F-A6C864263D4B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:conext_combox:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F2F9562-402D-4069-83C0-E5C5CE05F2AB\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T07:46:43.469Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-32516\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-05T19:55:08.252212Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-05T19:55:09.701Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Conext\\u2122 ComBox\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions\"}]}], \"datePublic\": \"2022-06-14T00:00:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\\u2122 ComBox (All Versions)\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-352\", \"description\": \"CWE-352 Cross-Site Request Forgery (CSRF)\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2023-01-30T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-32516\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-05T20:08:26.260Z\", \"dateReserved\": \"2022-06-07T00:00:00.000Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2023-01-30T00:00:00.000Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2022-AVI-546
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Conext ComBox toutes versions | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | CanBRASS versions antérieures à 7.6 | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à 7.9.1 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.22 | ||
| Schneider Electric | N/A | Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Cybersecurity Admin Expert (CAE) versions antérieures à 2.4 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22170 | ||
| Schneider Electric | N/A | Geo SCADA Mobile versions antérieures au Build 202205171 | ||
| Schneider Electric | N/A | Smart-UPS SRT Series versions antérieures à 15.0 | ||
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | EcoStruxure Power Build: Rapsody Software versions antérieures à 2.1.13 | ||
| Schneider Electric | N/A | EPC2000 versions antérieures à 4.03 | ||
| Schneider Electric | N/A | Versadac versions antérieures à 2.43 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500AC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Smart-UPS SCL Series versions antérieures à 15.1 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CanBRASS versions ant\u00e9rieures \u00e0 7.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 7.9.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Cybersecurity Admin Expert (CAE) versions ant\u00e9rieures \u00e0 2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22170",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Geo SCADA Mobile versions ant\u00e9rieures au Build 202205171",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SRT Series versions ant\u00e9rieures \u00e0 15.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build: Rapsody Software versions ant\u00e9rieures \u00e0 2.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 versions ant\u00e9rieures \u00e0 4.03",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Versadac versions ant\u00e9rieures \u00e0 2.43",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500AC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SCL Series versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-32524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32524"
},
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2022-22731",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22731"
},
{
"name": "CVE-2022-32514",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32514"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-32517",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32517"
},
{
"name": "CVE-2022-32526",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32526"
},
{
"name": "CVE-2022-32530",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32530"
},
{
"name": "CVE-2022-32748",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32748"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-32529",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32529"
},
{
"name": "CVE-2022-32513",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32513"
},
{
"name": "CVE-2022-32747",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32747"
},
{
"name": "CVE-2022-32523",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32523"
},
{
"name": "CVE-2022-32528",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32528"
},
{
"name": "CVE-2022-32516",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32516"
},
{
"name": "CVE-2022-32522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32522"
},
{
"name": "CVE-2022-32527",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32527"
},
{
"name": "CVE-2022-32515",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32515"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2022-0223",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0223"
},
{
"name": "CVE-2022-32519",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32519"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2022-32512",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32512"
},
{
"name": "CVE-2022-32518",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32518"
},
{
"name": "CVE-2022-22732",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22732"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-32520",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32520"
},
{
"name": "CVE-2022-32525",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32525"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
},
{
"name": "CVE-2022-32521",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32521"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-546",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-06-15T00:00:00.000000"
},
{
"description": "Modification de la version des produits IGSS Data Server",
"revision_date": "2022-06-23T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022.",
"revision_date": "2022-08-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-07 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-06 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-02 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-08 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-012-02 du 12 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-04 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_%20StruxureWare_Data_Center_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-01 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-05 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V8.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-03 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
}
CERTFR-2022-AVI-546
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Conext ComBox toutes versions | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | CanBRASS versions antérieures à 7.6 | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à 7.9.1 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.22 | ||
| Schneider Electric | N/A | Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Cybersecurity Admin Expert (CAE) versions antérieures à 2.4 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22170 | ||
| Schneider Electric | N/A | Geo SCADA Mobile versions antérieures au Build 202205171 | ||
| Schneider Electric | N/A | Smart-UPS SRT Series versions antérieures à 15.0 | ||
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | EcoStruxure Power Build: Rapsody Software versions antérieures à 2.1.13 | ||
| Schneider Electric | N/A | EPC2000 versions antérieures à 4.03 | ||
| Schneider Electric | N/A | Versadac versions antérieures à 2.43 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500AC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Smart-UPS SCL Series versions antérieures à 15.1 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CanBRASS versions ant\u00e9rieures \u00e0 7.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 7.9.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Cybersecurity Admin Expert (CAE) versions ant\u00e9rieures \u00e0 2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22170",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Geo SCADA Mobile versions ant\u00e9rieures au Build 202205171",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SRT Series versions ant\u00e9rieures \u00e0 15.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build: Rapsody Software versions ant\u00e9rieures \u00e0 2.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 versions ant\u00e9rieures \u00e0 4.03",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Versadac versions ant\u00e9rieures \u00e0 2.43",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500AC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SCL Series versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-32524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32524"
},
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2022-22731",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22731"
},
{
"name": "CVE-2022-32514",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32514"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-32517",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32517"
},
{
"name": "CVE-2022-32526",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32526"
},
{
"name": "CVE-2022-32530",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32530"
},
{
"name": "CVE-2022-32748",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32748"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-32529",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32529"
},
{
"name": "CVE-2022-32513",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32513"
},
{
"name": "CVE-2022-32747",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32747"
},
{
"name": "CVE-2022-32523",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32523"
},
{
"name": "CVE-2022-32528",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32528"
},
{
"name": "CVE-2022-32516",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32516"
},
{
"name": "CVE-2022-32522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32522"
},
{
"name": "CVE-2022-32527",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32527"
},
{
"name": "CVE-2022-32515",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32515"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2022-0223",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0223"
},
{
"name": "CVE-2022-32519",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32519"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2022-32512",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32512"
},
{
"name": "CVE-2022-32518",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32518"
},
{
"name": "CVE-2022-22732",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22732"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-32520",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32520"
},
{
"name": "CVE-2022-32525",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32525"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
},
{
"name": "CVE-2022-32521",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32521"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-546",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-06-15T00:00:00.000000"
},
{
"description": "Modification de la version des produits IGSS Data Server",
"revision_date": "2022-06-23T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022.",
"revision_date": "2022-08-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-07 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-06 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-02 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-08 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-012-02 du 12 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-04 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_%20StruxureWare_Data_Center_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-01 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-05 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V8.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-03 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
}
FKIE_CVE-2022-32516
Vulnerability from fkie_nvd - Published: 2023-01-30 23:15 - Updated: 2024-11-21 07:066.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf | Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | conext_combox_firmware | * | |
| schneider-electric | conext_combox | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:conext_combox_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "570ACEDE-DE9F-4E19-AA0F-A6C864263D4B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:conext_combox:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F2F9562-402D-4069-83C0-E5C5CE05F2AB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions)"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE-352: Cross Site Request Forgery (CSRF) que podr\u00eda causar que las configuraciones del sistema se anulen y provoquen un bucle de reinicio cuando el producto sufre una Cross Site Request Forgery (CSRF) basada en POST. Productos afectados: Conext? ComBox (todas las versiones)"
}
],
"id": "CVE-2022-32516",
"lastModified": "2024-11-21T07:06:32.330",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-01-30T23:15:10.170",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
CVE-2022-32516
Vulnerability from csaf_se - Published: 2022-06-14 18:30 - Updated: 2022-06-14 18:30Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its Conext\u2122 ComBox product which was discontinued in January 2020 and is no longer in support.\r\nThe Conext\u2122 ComBox is a communication and monitoring device for installers and operators of Conext solar systems. It features an integrated web server, enabling graphical displays of system daily, monthly and lifetime energy data to be viewed using a simple web browser or Android tablet device.\r\nFailure to apply the mitigations provided below may risk Clickjacking, Rate Limiting \u0026 Cross-Site Request Forgery attacks. An attacker who successfully exploits one or more of these vulnerabilities could trick the product user/admin into performing unintended actions that may lead to taking over their account or manipulating the station settings.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Conext\u2122 Combox - SEVD-2022-165-03 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2022-165-03.json"
},
{
"category": "self",
"summary": "Conext\u2122 Combox - SEVD-2022-165-03 PDF Version",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
},
{
"category": "self",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Conext\u2122 Combox",
"tracking": {
"current_release_date": "2022-06-14T18:30:00.000Z",
"generator": {
"date": "2022-06-11T08:58:38.344Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.1"
}
},
"id": "SEVD-2022-165-03",
"initial_release_date": "2022-06-14T18:30:00.000Z",
"revision_history": [
{
"date": "2022-06-14T09:09:41.000Z",
"number": "1",
"summary": "Original Release"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All Versions",
"product": {
"name": "Schneider Electric Conext\u2122 ComBox All Versions",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Conext\u2122 ComBox"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Tony Marcel Nasr"
]
}
],
"cve": "CVE-2022-32515",
"cwe": {
"id": "CWE-307",
"name": "Improper Restriction of Excessive Authentication Attempts"
},
"notes": [
{
"category": "description",
"text": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Conext\u2122 ComBox product was discontinued as of January 2020 and is no longer in support. Customers should immediately apply the following mitigations to reduce the risk of exploit: \r\n Do not expose the Conext\u2122 Combox directly to the Internet \r\n Do not grant network access to unknown computers\r\n Computer(s) must be kept up to date with the latest security patches \r\n Customers should also consider upgrading to the latest product offering InsightHome \u0026 InsightFacility to resolve these issues.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://solar.se.com/us/en/product/insighthome-and-insightfacility-edge-devices/#videos"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-32515"
},
{
"acknowledgments": [
{
"names": [
"Tony Marcel Nasr"
]
}
],
"cve": "CVE-2022-32516",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"category": "description",
"text": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF)",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Conext\u2122 ComBox product was discontinued as of January 2020 and is no longer in support. Customers should immediately apply the following mitigations to reduce the risk of exploit: \r\n Do not expose the Conext\u2122 Combox directly to the Internet \r\n Do not grant network access to unknown computers\r\n Computer(s) must be kept up to date with the latest security patches \r\n Customers should also consider upgrading to the latest product offering InsightHome \u0026 InsightFacility to resolve these issues.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://solar.se.com/us/en/product/insighthome-and-insightfacility-edge-devices/#videos"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-32516"
},
{
"acknowledgments": [
{
"names": [
"Tony Marcel Nasr"
]
}
],
"cve": "CVE-2022-32517",
"cwe": {
"id": "CWE-1021",
"name": "Improper Restriction of Rendered UI Layers or Frames"
},
"notes": [
{
"category": "description",
"text": "A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Conext\u2122 ComBox product was discontinued as of January 2020 and is no longer in support. Customers should immediately apply the following mitigations to reduce the risk of exploit: \r\n Do not expose the Conext\u2122 Combox directly to the Internet \r\n Do not grant network access to unknown computers\r\n Computer(s) must be kept up to date with the latest security patches \r\n Customers should also consider upgrading to the latest product offering InsightHome \u0026 InsightFacility to resolve these issues.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://solar.se.com/us/en/product/insighthome-and-insightfacility-edge-devices/#videos"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-32517"
}
]
}
GHSA-GQGC-W6W9-6H7C
Vulnerability from github – Published: 2023-07-06 19:24 – Updated: 2024-04-04 05:32A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system’s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext™ ComBox (All Versions)
{
"affected": [],
"aliases": [
"CVE-2022-32516"
],
"database_specific": {
"cwe_ids": [
"CWE-352"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-01-30T23:15:00Z",
"severity": "MODERATE"
},
"details": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions)",
"id": "GHSA-gqgc-w6w9-6h7c",
"modified": "2024-04-04T05:32:05Z",
"published": "2023-07-06T19:24:08Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-32516"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
CVE-2022-32516
Vulnerability from fstec - Published: 14.06.2022{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "- (Conext ComBox)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0443 \u0438\u0437 \u043e\u0431\u0449\u0435\u0434\u043e\u0441\u0442\u0443\u043f\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439 (\u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442);\n- \u0441\u043e\u0431\u043b\u044e\u0434\u0435\u043d\u0438\u0435 \u0442\u0440\u0435\u0431\u043e\u0432\u0430\u043d\u0438\u0439 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u043f\u0440\u0438\u043d\u044f\u0442\u044b\u043c\u0438 \u0440\u0435\u0433\u043b\u0430\u043c\u0435\u043d\u0442\u0430\u043c\u0438.",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "14.06.2022",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "11.07.2022",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "11.07.2022",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2022-04253",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2022-32516",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u0435\u0442",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Conext ComBox",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0441\u0432\u044f\u0437\u0438 \u0438 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 Schneider Electric Conext ComBox, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043f\u043e\u0434\u0434\u0435\u043b\u043a\u043e\u0439 \u043c\u0435\u0436\u0441\u0430\u0439\u0442\u043e\u0432\u044b\u0445 \u0437\u0430\u043f\u0440\u043e\u0441\u043e\u0432, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041c\u0435\u0436\u0441\u0430\u0439\u0442\u043e\u0432\u0430\u044f \u0444\u0430\u043b\u044c\u0441\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f \u0437\u0430\u043f\u0440\u043e\u0441\u043e\u0432 (CWE-352)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0441\u0432\u044f\u0437\u0438 \u0438 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 Schneider Electric Conext ComBox \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043f\u043e\u0434\u0434\u0435\u043b\u043a\u043e\u0439 \u043c\u0435\u0436\u0441\u0430\u0439\u0442\u043e\u0432\u044b\u0445 \u0437\u0430\u043f\u0440\u043e\u0441\u043e\u0432. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u043e\u0437\u0434\u0430\u043d\u043d\u043e\u0433\u043e \u0437\u0430\u043f\u0440\u043e\u0441\u0430 POST",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043c\u0435\u0440\u044b",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041f\u043e\u0434\u043c\u0435\u043d\u0430 \u043f\u0440\u0438 \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-352",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)"
}
VAR-202301-2271
Vulnerability from variot - Updated: 2023-12-18 12:41A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system’s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext™ ComBox (All Versions). Schneider Electric Conext ComBox is a powerful communication and monitoring device from the French company Schneider Electric
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202301-2271",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "conext combox",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "*"
},
{
"model": "conext combox",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "conext combox",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "conext combox",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "conext combox firmware"
},
{
"model": "electric conext combox",
"scope": null,
"trust": 0.6,
"vendor": "schneider",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40178"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"db": "NVD",
"id": "CVE-2022-32516"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:conext_combox_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:conext_combox:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-32516"
}
]
},
"cve": "CVE-2022-32516",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-40178",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cybersecurity@se.com",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-32516",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-32516",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "cybersecurity@se.com",
"id": "CVE-2022-32516",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2023-40178",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202301-2331",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40178"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"db": "NVD",
"id": "CVE-2022-32516"
},
{
"db": "NVD",
"id": "CVE-2022-32516"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-2331"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions). Schneider Electric Conext ComBox is a powerful communication and monitoring device from the French company Schneider Electric",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-32516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"db": "CNVD",
"id": "CNVD-2023-40178"
},
{
"db": "VULMON",
"id": "CVE-2022-32516"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-32516",
"trust": 3.9
},
{
"db": "SCHNEIDER",
"id": "SEVD-2022-165-03",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2022-012136",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-40178",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202301-2331",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-32516",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40178"
},
{
"db": "VULMON",
"id": "CVE-2022-32516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"db": "NVD",
"id": "CVE-2022-32516"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-2331"
}
]
},
"id": "VAR-202301-2271",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40178"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40178"
}
]
},
"last_update_date": "2023-12-18T12:41:23.694000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SEVD-2022-165-03",
"trust": 0.8,
"url": "https://download.schneider-electric.com/files?p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2022-165-03_conextcombox_security_notification.pdf"
},
{
"title": "Patch for Schneider Electric Conext ComBox Cross Site Request Forgery Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/428661"
},
{
"title": "Schneider Electric Conext ComBox Fixes for cross-site request forgery vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=224234"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40178"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-2331"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-352",
"trust": 1.0
},
{
"problemtype": "Cross-site request forgery (CWE-352) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"db": "NVD",
"id": "CVE-2022-32516"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://download.schneider-electric.com/files?p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2022-165-03_conextcombox_security_notification.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-32516"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-32516/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/352.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40178"
},
{
"db": "VULMON",
"id": "CVE-2022-32516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"db": "NVD",
"id": "CVE-2022-32516"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-2331"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-40178"
},
{
"db": "VULMON",
"id": "CVE-2022-32516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"db": "NVD",
"id": "CVE-2022-32516"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-2331"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-05-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-40178"
},
{
"date": "2023-01-30T00:00:00",
"db": "VULMON",
"id": "CVE-2022-32516"
},
{
"date": "2023-08-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"date": "2023-01-30T23:15:10.170000",
"db": "NVD",
"id": "CVE-2022-32516"
},
{
"date": "2023-01-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202301-2331"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-05-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-40178"
},
{
"date": "2023-01-31T00:00:00",
"db": "VULMON",
"id": "CVE-2022-32516"
},
{
"date": "2023-08-28T02:58:00",
"db": "JVNDB",
"id": "JVNDB-2022-012136"
},
{
"date": "2023-02-07T18:54:26.637000",
"db": "NVD",
"id": "CVE-2022-32516"
},
{
"date": "2023-02-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202301-2331"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202301-2331"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Conext\u00a0ComBox\u00a0 Cross-site request forgery vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-012136"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "cross-site request forgery",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202301-2331"
}
],
"trust": 0.6
}
}
GSD-2022-32516
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-32516",
"description": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions)",
"id": "GSD-2022-32516"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-32516"
],
"details": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions)",
"id": "GSD-2022-32516",
"modified": "2023-12-13T01:19:12.270722Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-06-14T07:00:00.000Z",
"ID": "CVE-2022-32516",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Conext\u2122 ComBox",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-352 Cross-Site Request Forgery (CSRF)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:conext_combox_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:conext_combox:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-32516"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system\u2019s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext\u2122 ComBox (All Versions)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-02-07T18:54Z",
"publishedDate": "2023-01-30T23:15Z"
}
}
}
CNVD-2023-40178
Vulnerability from cnvd - Published: 2023-05-25厂商已发布了漏洞修复程序,请及时关注更新: https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf
| Name | Schneider Electric Conext ComBox |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2022-32516",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2022-32516"
}
},
"description": "Schneider Electric Conext ComBox\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u901a\u4fe1\u548c\u76d1\u63a7\u8bbe\u5907\u3002\n\nSchneider Electric Conext ComBox\u5b58\u5728\u8de8\u7ad9\u8bf7\u6c42\u4f2a\u9020\u6f0f\u6d1e\uff0c\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u4ee5\u5229\u7528\u8be5\u6f0f\u6d1e\u6784\u5efa\u6076\u610fURI\uff0c\u8bf1\u4f7f\u8bf7\u6c42\uff0c\u5b9e\u73b0\u8986\u76d6\u7cfb\u7edf\u914d\u7f6e\u5e76\u5bfc\u81f4\u5faa\u73af\u91cd\u65b0\u542f\u52a8\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2023-40178",
"openTime": "2023-05-25",
"patchDescription": "Schneider Electric Conext ComBox\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u901a\u4fe1\u548c\u76d1\u63a7\u8bbe\u5907\u3002\r\n\r\nSchneider Electric Conext ComBox\u5b58\u5728\u8de8\u7ad9\u8bf7\u6c42\u4f2a\u9020\u6f0f\u6d1e\uff0c\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u4ee5\u5229\u7528\u8be5\u6f0f\u6d1e\u6784\u5efa\u6076\u610fURI\uff0c\u8bf1\u4f7f\u8bf7\u6c42\uff0c\u5b9e\u73b0\u8986\u76d6\u7cfb\u7edf\u914d\u7f6e\u5e76\u5bfc\u81f4\u5faa\u73af\u91cd\u65b0\u542f\u52a8\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric Conext ComBox\u8de8\u7ad9\u8bf7\u6c42\u4f2a\u9020\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Schneider Electric Conext ComBox"
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2022-32516",
"serverity": "\u9ad8",
"submitTime": "2023-02-06",
"title": "Schneider Electric Conext ComBox\u8de8\u7ad9\u8bf7\u6c42\u4f2a\u9020\u6f0f\u6d1e"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.