CVE-2022-27485 (GCVE-0-2022-27485)
Vulnerability from cvelistv5
Published
2023-04-11 16:07
Modified
2024-10-22 20:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-89 - Information disclosure
Summary
A improper neutralization of special elements used in an sql command ('sql injection') vulnerability [CWE-89] in Fortinet FortiSandbox version 4.2.0, 4.0.0 through 4.0.2, 3.2.0 through 3.2.3, 3.1.x and 3.0.x allows a remote and authenticated attacker with read permission to retrieve arbitrary files from the underlying Linux system via a crafted HTTP request.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fortinet | FortiSandbox |
Version: 4.2.0 Version: 4.0.0 ≤ 4.0.2 Version: 3.2.0 ≤ 3.2.3 Version: 3.1.0 ≤ 3.1.5 Version: 3.0.1 ≤ 3.0.7 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:57.889Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://fortiguard.com/psirt/FG-IR-22-060",
"tags": [
"x_transferred"
],
"url": "https://fortiguard.com/psirt/FG-IR-22-060"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-27485",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-22T20:18:13.988162Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-22T20:47:12.883Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FortiSandbox",
"vendor": "Fortinet",
"versions": [
{
"status": "affected",
"version": "4.2.0"
},
{
"lessThanOrEqual": "4.0.2",
"status": "affected",
"version": "4.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "3.2.3",
"status": "affected",
"version": "3.2.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "3.1.5",
"status": "affected",
"version": "3.1.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "3.0.7",
"status": "affected",
"version": "3.0.1",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A improper neutralization of special elements used in an sql command (\u0027sql injection\u0027) vulnerability [CWE-89] in Fortinet FortiSandbox version 4.2.0, 4.0.0 through 4.0.2, 3.2.0 through 3.2.3, 3.1.x and 3.0.x allows a remote and authenticated attacker with read permission to retrieve\u00a0arbitrary files from the underlying Linux system via a crafted HTTP request."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:C",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "Information disclosure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T16:07:08.880Z",
"orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
"shortName": "fortinet"
},
"references": [
{
"name": "https://fortiguard.com/psirt/FG-IR-22-060",
"url": "https://fortiguard.com/psirt/FG-IR-22-060"
}
],
"solutions": [
{
"lang": "en",
"value": "Please upgrade to FortiSandbox version 4.2.1 or above Please upgrade to FortiSandbox version 4.0.3 or above Please upgrade to FortiSandbox version 3.2.4 or above "
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
"assignerShortName": "fortinet",
"cveId": "CVE-2022-27485",
"datePublished": "2023-04-11T16:07:08.880Z",
"dateReserved": "2022-03-21T16:03:48.574Z",
"dateUpdated": "2024-10-22T20:47:12.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-27485\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2023-04-11T17:15:07.130\",\"lastModified\":\"2024-11-21T06:55:49.123\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A improper neutralization of special elements used in an sql command (\u0027sql injection\u0027) vulnerability [CWE-89] in Fortinet FortiSandbox version 4.2.0, 4.0.0 through 4.0.2, 3.2.0 through 3.2.3, 3.1.x and 3.0.x allows a remote and authenticated attacker with read permission to retrieve\u00a0arbitrary files from the underlying Linux system via a crafted HTTP request.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortisandbox:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0.1\",\"versionEndIncluding\":\"3.0.7\",\"matchCriteriaId\":\"AF8BA034-3CD8-4AE7-AAE1-5E12435F6E84\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortisandbox:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.1.0\",\"versionEndExcluding\":\"3.2.4\",\"matchCriteriaId\":\"4B43C486-DC53-4F71-A3D4-EA1863A99060\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortisandbox:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.0.0\",\"versionEndExcluding\":\"4.0.3\",\"matchCriteriaId\":\"4AD1B101-4071-480C-AF8A-AE66FF92D589\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortisandbox:4.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB56C6F6-9FE4-4FAF-8AEC-A1C6205F94C5\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/psirt/FG-IR-22-060\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://fortiguard.com/psirt/FG-IR-22-060\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://fortiguard.com/psirt/FG-IR-22-060\", \"name\": \"https://fortiguard.com/psirt/FG-IR-22-060\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T05:32:57.889Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-27485\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-22T20:18:13.988162Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-22T20:20:33.350Z\"}}], \"cna\": {\"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:C\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Fortinet\", \"product\": \"FortiSandbox\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.2.0\"}, {\"status\": \"affected\", \"version\": \"4.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"4.0.2\"}, {\"status\": \"affected\", \"version\": \"3.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"3.2.3\"}, {\"status\": \"affected\", \"version\": \"3.1.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"3.1.5\"}, {\"status\": \"affected\", \"version\": \"3.0.1\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"3.0.7\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Please upgrade to FortiSandbox version 4.2.1 or above Please upgrade to FortiSandbox version 4.0.3 or above Please upgrade to FortiSandbox version 3.2.4 or above \"}], \"references\": [{\"url\": \"https://fortiguard.com/psirt/FG-IR-22-060\", \"name\": \"https://fortiguard.com/psirt/FG-IR-22-060\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A improper neutralization of special elements used in an sql command (\u0027sql injection\u0027) vulnerability [CWE-89] in Fortinet FortiSandbox version 4.2.0, 4.0.0 through 4.0.2, 3.2.0 through 3.2.3, 3.1.x and 3.0.x allows a remote and authenticated attacker with read permission to retrieve\\u00a0arbitrary files from the underlying Linux system via a crafted HTTP request.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-89\", \"description\": \"Information disclosure\"}]}], \"providerMetadata\": {\"orgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"shortName\": \"fortinet\", \"dateUpdated\": \"2023-04-11T16:07:08.880Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-27485\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-22T20:47:12.883Z\", \"dateReserved\": \"2022-03-21T16:03:48.574Z\", \"assignerOrgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"datePublished\": \"2023-04-11T16:07:08.880Z\", \"assignerShortName\": \"fortinet\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…