CVE-2022-23009 (GCVE-0-2022-23009)
Vulnerability from cvelistv5
Published
2022-01-25 19:11
Modified
2024-08-03 03:28
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-863 - Incorrect Authorization
Summary
On BIG-IQ Centralized Management 8.x before 8.1.0, an authenticated administrative role user on a BIG-IQ managed BIG-IP device can access other BIG-IP devices managed by the same BIG-IQ system. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | BIG-IQ Centralized Management |
Version: 8.x before 8.1.0 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:28:42.754Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.f5.com/csp/article/K47592780"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BIG-IQ Centralized Management",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "8.x before 8.1.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On BIG-IQ Centralized Management 8.x before 8.1.0, an authenticated administrative role user on a BIG-IQ managed BIG-IP device can access other BIG-IP devices managed by the same BIG-IQ system. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-25T19:11:18",
"orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
"shortName": "f5"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.f5.com/csp/article/K47592780"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "f5sirt@f5.com",
"ID": "CVE-2022-23009",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BIG-IQ Centralized Management",
"version": {
"version_data": [
{
"version_value": "8.x before 8.1.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On BIG-IQ Centralized Management 8.x before 8.1.0, an authenticated administrative role user on a BIG-IQ managed BIG-IP device can access other BIG-IP devices managed by the same BIG-IQ system. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-863: Incorrect Authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.f5.com/csp/article/K47592780",
"refsource": "MISC",
"url": "https://support.f5.com/csp/article/K47592780"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
"assignerShortName": "f5",
"cveId": "CVE-2022-23009",
"datePublished": "2022-01-25T19:11:18",
"dateReserved": "2022-01-10T00:00:00",
"dateUpdated": "2024-08-03T03:28:42.754Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-23009\",\"sourceIdentifier\":\"f5sirt@f5.com\",\"published\":\"2022-01-25T20:15:09.050\",\"lastModified\":\"2024-11-21T06:47:47.743\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"On BIG-IQ Centralized Management 8.x before 8.1.0, an authenticated administrative role user on a BIG-IQ managed BIG-IP device can access other BIG-IP devices managed by the same BIG-IQ system. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.\"},{\"lang\":\"es\",\"value\":\"En BIG-IQ Centralized Management versiones 8.x anteriores a 8.1.0, un usuario con rol administrativo autenticado en un dispositivo BIG-IP administrado por BIG-IQ puede acceder a otros dispositivos BIG-IP administrados por el mismo sistema BIG-IQ. Nota: Las versiones de software que han alcanzado el Fin de Soporte T\u00e9cnico (EoTS) no son evaluadas\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"f5sirt@f5.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:f5:big-iq_centralized_management:8.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"756F8EDF-6F87-4C6D-B2DB-ED97F799C27F\"}]}]}],\"references\":[{\"url\":\"https://support.f5.com/csp/article/K47592780\",\"source\":\"f5sirt@f5.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://support.f5.com/csp/article/K47592780\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…