CVE-2022-22985 (GCVE-0-2022-22985)

Vulnerability from cvelistv5 – Published: 2022-03-09 15:33 – Updated: 2025-04-16 18:00
VLAI?
Title
ICSA-22-062-01 IPCOMM ipDIO
Summary
The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history.
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Credits
Aarón Flecha Menéndez of S21Sec reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:28:42.832Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-22985",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:31:07.238733Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:00:18.257Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IPCOMM ipDIO",
          "vendor": "IPCOMM",
          "versions": [
            {
              "status": "affected",
              "version": "3.9"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Aar\u00f3n Flecha Men\u00e9ndez of S21Sec reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2022-03-03T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-09T15:33:40.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "IPCOMM recommends upgrading to its ip4Cloud device, which is the successor to ipDIO. Contact IPCOMM customer support for assistance with the upgrade. For more information, visit the IPCOMM ip4Cloud product page."
        }
      ],
      "source": {
        "advisory": "ICSA-22-062-01",
        "discovery": "EXTERNAL"
      },
      "title": "ICSA-22-062-01 IPCOMM ipDIO",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-03-03T18:40:00.000Z",
          "ID": "CVE-2022-22985",
          "STATE": "PUBLIC",
          "TITLE": "ICSA-22-062-01 IPCOMM ipDIO"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IPCOMM ipDIO",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "3.9",
                            "version_value": "3.9"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "IPCOMM"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Aar\u00f3n Flecha Men\u00e9ndez of S21Sec reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "IPCOMM recommends upgrading to its ip4Cloud device, which is the successor to ipDIO. Contact IPCOMM customer support for assistance with the upgrade. For more information, visit the IPCOMM ip4Cloud product page."
          }
        ],
        "source": {
          "advisory": "ICSA-22-062-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-22985",
    "datePublished": "2022-03-09T15:33:40.335Z",
    "dateReserved": "2022-02-15T00:00:00.000Z",
    "dateUpdated": "2025-04-16T18:00:18.257Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ipcomm:ipdio_firmware:3.9:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7CCFF2C1-ED64-44C3-94D3-D5179BB3F822\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ipcomm:ipdio:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"034252D1-4CDB-4813-8831-8A0CCBC1E1C4\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history.\"}, {\"lang\": \"es\", \"value\": \"La ausencia de filtros cuando son cargadas algunas secciones en la aplicaci\\u00f3n web del dispositivo vulnerable permite a atacantes inyectar c\\u00f3digo malicioso que ser\\u00e1 interpretado cuando un usuario leg\\u00edtimo acceda a la secci\\u00f3n web espec\\u00edfica donde es mostrada la informaci\\u00f3n. La inyecci\\u00f3n puede realizarse sobre par\\u00e1metros espec\\u00edficos. El c\\u00f3digo inyectado es ejecutado cuando un usuario leg\\u00edtimo intenta revisar el historial\"}]",
      "id": "CVE-2022-22985",
      "lastModified": "2024-11-21T06:47:44.610",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2022-03-10T17:45:43.893",
      "references": "[{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-94\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-22985\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-03-10T17:45:43.893\",\"lastModified\":\"2024-11-21T06:47:44.610\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history.\"},{\"lang\":\"es\",\"value\":\"La ausencia de filtros cuando son cargadas algunas secciones en la aplicaci\u00f3n web del dispositivo vulnerable permite a atacantes inyectar c\u00f3digo malicioso que ser\u00e1 interpretado cuando un usuario leg\u00edtimo acceda a la secci\u00f3n web espec\u00edfica donde es mostrada la informaci\u00f3n. La inyecci\u00f3n puede realizarse sobre par\u00e1metros espec\u00edficos. El c\u00f3digo inyectado es ejecutado cuando un usuario leg\u00edtimo intenta revisar el historial\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ipcomm:ipdio_firmware:3.9:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CCFF2C1-ED64-44C3-94D3-D5179BB3F822\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ipcomm:ipdio:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"034252D1-4CDB-4813-8831-8A0CCBC1E1C4\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T03:28:42.832Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-22985\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-16T17:31:07.238733Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-16T17:31:08.592Z\"}}], \"cna\": {\"title\": \"ICSA-22-062-01 IPCOMM ipDIO\", \"source\": {\"advisory\": \"ICSA-22-062-01\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"value\": \"Aar\\u00f3n Flecha Men\\u00e9ndez of S21Sec reported these vulnerabilities to CISA.\"}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"IPCOMM\", \"product\": \"IPCOMM ipDIO\", \"versions\": [{\"status\": \"affected\", \"version\": \"3.9\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"IPCOMM recommends upgrading to its ip4Cloud device, which is the successor to ipDIO. Contact IPCOMM customer support for assistance with the upgrade. For more information, visit the IPCOMM ip4Cloud product page.\"}], \"datePublic\": \"2022-03-03T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01\", \"tags\": [\"x_refsource_MISC\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-94\", \"description\": \"CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2022-03-09T15:33:40.000Z\"}, \"x_legacyV4Record\": {\"credit\": [{\"lang\": \"eng\", \"value\": \"Aar\\u00f3n Flecha Men\\u00e9ndez of S21Sec reported these vulnerabilities to CISA.\"}], \"impact\": {\"cvss\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, \"source\": {\"advisory\": \"ICSA-22-062-01\", \"discovery\": \"EXTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_name\": \"3.9\", \"version_value\": \"3.9\", \"version_affected\": \"=\"}]}, \"product_name\": \"IPCOMM ipDIO\"}]}, \"vendor_name\": \"IPCOMM\"}]}}, \"solution\": [{\"lang\": \"en\", \"value\": \"IPCOMM recommends upgrading to its ip4Cloud device, which is the successor to ipDIO. Contact IPCOMM customer support for assistance with the upgrade. For more information, visit the IPCOMM ip4Cloud product page.\"}], \"data_type\": \"CVE\", \"generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"references\": {\"reference_data\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01\", \"name\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-062-01\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-22985\", \"STATE\": \"PUBLIC\", \"TITLE\": \"ICSA-22-062-01 IPCOMM ipDIO\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\", \"DATE_PUBLIC\": \"2022-03-03T18:40:00.000Z\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-22985\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-16T18:00:18.257Z\", \"dateReserved\": \"2022-02-15T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2022-03-09T15:33:40.335Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…